English
Related papers

Related papers: The GAP-TPC

200 papers

A 10 kilo-tonne dual-phase liquid argon TPC is one of the detector options considered for the Deep Underground Neutrino Experiment (DUNE). The detector technology relies on amplification of the ionisation charge in ultra-pure argon vapour…

Instrumentation and Detectors · Physics 2018-11-14 B. Aimard , Ch. Alt , J. Asaadi , M. Auger , V. Aushev , D. Autiero , M. M. Badoi , A. Balaceanu , G. Balik , L. Balleyguier , E. Bechetoille , D. Belver , A. M. Blebea-Apostu , S. Bolognesi , S. Bordoni , N. Bourgeois , B. Bourguille , J. Bremer , G. Brown , G. Brunetti , L. Brunetti , D. Caiulo , M. Calin , E. Calvo , M. Campanelli , K. Cankocak , C. Cantini , B. Carlus , B. M. Cautisanu , M. Chalifour , A. Chappuis , N. Charitonidis , A. Chatterjee , A. Chiriacescu , P. Chiu , S. Conforti , P. Cotte , P. Crivelli , C. Cuesta , J. Dawson , I. De Bonis , C. De La Taille , A. Delbart , D. Desforge , S. Di Luise , B. S. Dimitru , F. Doizon , C. Drancourt , D. Duchesneau , F. Dulucq , J. Dumarchez , F. Duval , S. Emery , A. Ereditato , T. Esanu , A. Falcone , K. Fusshoeller , A. Gallego-Ros , V. Galymov , N. Geroy , A. Gendotti , M. Gherghel-Lascu , C. Giganti , I. Gil-Botella , C. Girerd , M. C. Gomoiu , P. Gorodetzky , E. Hamada , R. Hanni , T. Hasegawa , A. Holin , S. Horikawa , M. Ikeno , S. Jimenez , A. Jipa , M. Karolak , Y. Karyotakis , S. Kasai , K. Kasami , T. Kishishita , I. Kreslo , D. Kryn , C. Lastoria , I. Lazanu , G. Lehmann-Miotto , N. Lira , K. Loo , D. Lorca , P. Lutz , T. Lux , J. Maalampi , G. Maire , M. Maki , L. Manenti , R. M. Margineanu , J. Marteau , G. Martin-Chassard , H. Mathez , E. Mazzucato , G. Misitano , B. Mitrica , D. Mladenov , L. Molina Bueno , C. Moreno Martinez , J. P. Mols , T. S. Mosu , W. Mug , A. Munteanu , S. Murphy , K. Nakayoshi , S. Narita , D. Navas-Nicolas , K. Negishi , M. Nessi , M. Niculescu-Oglinzanu , L. Nita , F. Noto , A. Noury , Y. Onishchuk , C. Palomares , M. Parvu , T. Patzak , Y. Penichot , E. Pennacchio , L. Periale , H. Pessard , F. Pietropaolo , Y. Piret , B. Popov , D. Pugnere , B. Radics , D. Redondo , C. Regenfus , A. Remoto , F. Resnati , Y. A. Rigaut , C. Ristea , A. Rubbia , A. Saftoiu , K. Sakashita , F. Sanchez , C. Santos , A. Scarpelli , C. Schloesser , L. Scotto Lavina , K. Sendai , F. Sergiampietri , S. Shahsavarani , M. Shoji , J. Sinclair , J. Soto-Oton , D. L. Stanca , D. Stefan , P. Stroescu , R. Sulej , M. Tanaka , V. Toboaru , A. Tonazzo , W. Tromeur , W. H. Trzaska , T. Uchida , F. Vannucci , G. Vasseur , A. Verdugo , T. Viant , S. Vihonen , S. Vilalte , M. Weber , S. Wu , J. Yu , L. Zambelli , M. Zito

The detection of photons with energies greater than a few tenths of an MeV, interacting via Compton scattering and/or pair production, faces a number of difficulties. The reconstruction of single-scatter Compton events can only determine…

Instrumentation and Methods for Astrophysics · Physics 2023-04-05 Denis Bernard , Stanley D. Hunter , Toru Tanimori

Background: The established GADGET detection system, designed for measuring weak, low-energy $\beta$-delayed proton decays, features a gaseous Proton Detector with MICROMEGAS readout for calorimetric particle detection, surrounded by a…

The CYGNO project aims at the development of a high precision optical readout gaseous Tima Projection Chamber (TPC) for directional dark matter (DM) searches, to be hosted at Laboratori Nazionali del Gran Sasso (LNGS). CYGNO employs a…

We present a new technology for the shaping of the electric field in Time Projection Chambers (TPCs) using a carbon-loaded polyimide foil. This technology allows for the minimisation of passive material near the active volume of the TPC and…

We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in…

Nowadays there is compelling evidence for the existence of dark matter in the Universe. A general consensus has been expressed on the need for a directional sensitive detector to confirm, with a complementary approach, the candidates found…

The presented results are part of a feasibility study of a Super- heated Superconducting Granule (SSG) device for weakly interacting massive particles (WIMPs) detection. The sensitivity of SSG to nuclear recoils has been explored…

Astrophysics · Physics 2009-09-25 A. Gabutti

The DARWIN/XLZD experiment is a next-generation dark matter detector with a multi-ten-ton liquid xenon time projection chamber at its core. Its principal goal will be to explore the experimentally accessible parameter space for Weakly…

Instrumentation and Methods for Astrophysics · Physics 2024-05-01 Laura Baudis

The GAPS experiment is designed to carry out a sensitive dark matter search by measuring low-energy cosmic ray antideuterons and antiprotons. GAPS will provide a new avenue to access a wide range of dark matter models and masses that is…

In experiments searching for rare signals, background events from the detector itself are some of the major factors limiting search sensitivity.Screening for ultra-low radioactive detector materials is becoming ever more essential. We…

Instrumentation and Detectors · Physics 2021-12-24 Haiyan Du , Chengbo Du , Karl Giboni , Ke Han , Shengming He , Liqiang Liu , Yue Meng , Shaobo Wang , Tao Zhang , Li Zhao , Jifang Zhou

We present here a search for WIMP dark matter using 790.8 live-days of data collected with 3269 kg of liquid argon (1266 kg fiducial) by the DEAP-3600 detector at SNOLAB, using the Profile Likelihood Ratio method. The likelihood model is…

High Energy Physics - Experiment · Physics 2026-03-17 DEAP Collaboration , P. Adhikari , R. Ajaj , M. Alpízar-Venegas , P. -A. Amaudruz , J. Anstey , D. J. Auty , M. Baldwin , M. Batygov , B. Beltran , A. Bigentini , C. E. Bina , W. Bonivento , M. G. Boulay , J. F. Bueno , P. M. Burghardt , A. Butcher , M. Cadeddu , B. Cai , M. Cárdenas-Montes , S. Cavuoti , Y. Chen , S. Choudhary , B. T. Cleveland , R. Crampton , S. Daugherty , P. DelGobbo , P. Di Stefano , G. Dolganov , L. Doria , F. A. Duncan , M. Dunford , E. Ellingwood , A. Erlandson , S. S. Farahani , N. Fatemighomi , G. Fiorillo , R. J. Ford , D. Gahan , D. Gallacher , A. Garai , P. García Abia , S. Garg , P. Giampa , A. Giménez-Alcázar , D. Goeldi , P. Gorel , K. Graham , A. Grobov , A. L. Hallin , M. Hamstra , S. Haskins , J. Hu , J. Hucker , D. Huff , T. Hugues , A. Ilyasov , B. Jigmeddorj , C. J. Jillings , A. Joy , G. Kaur , A. Kemp , M. Khoshraftar Yazdi , M. Kuźniak , F. La Zia , M. Lai , S. Langrock , B. Lehnert , J. LePage-Bourbonnais , M. Lissia , L. Luzzi , I. Machulin , P. Majewski , A. Maru , J. Mason , A. B. McDonald , T. McElroy , J. B. McLaughlin , C. Mielnichuk , L. Mirasola , A. Moharana , J. Monroe , A. Murray , M. Needs , C. Ng , G. Oliviéro , M. Olszewski , S. Pal , D. Papi , B. Park , M. Perry , V. Pesudo , T. R. Pollmann , F. Rad , C. Rethmeier , F. Retière , I. Rodríguez García , L. Roszkowski , R. Santorelli , F. G. Schuckman , N. Seeburn , S. Seth , V. Shalamova , P. Skensved , T. Smirnova , N. J. T. Smith , K. Sobotkiewich , T. Sonley , J. Sosiak , J. Soukup , R. Stainforth , M. Stringer , J. Tang , P. Taylor , R. Turcotte-Tardif , E. Vázquez-Jáuregui , G. Vera Díaz , S. Viel , B. Vyas , M. Walczak , J. Walding , M. Ward , S. Westerdale , R. Wormington , A. Zuñiga-Reyes

Measurements with a bare p-type high purity germanium diode (HPGe) submerged in a 19 kg liquid argon (LAr) scintillation detector at MPIK Heidelberg are reported. The liquid argon--germanium system (LArGe) is operated as a 4$\pi$…

Instrumentation and Detectors · Physics 2008-11-26 M. Di Marco , P. Peiffer , S. Schönert

The absence of conclusive signals in weakly interacting massive particle (WIMP) searches has motivated increased interest in alternative dark matter candidates such as axions and axion-like particles (ALPs), which also provide a solution to…

High Energy Physics - Experiment · Physics 2026-04-07 S. Sahoo , S. Verma , M. Mirzakhani , N. Mishra , A. Thompson , S. Maludze , R. Mahapatra , M. Platt

In some experiments and applications there is need for large-area photosensitive detectors to operate at cryogenic temperatures. Nowadays, vacuum PMs are usually used for this purpose. We have developed special designs of planar…

Instrumentation and Detectors · Physics 2009-11-11 L. Periale , V. Peskov , C. Iacobaeus , B. Lund-Jensen , P. Pavlopoulos , P. Picchi , F. Pietropaolo

We report the results of the analyses of the cosmic ray data collected with a 4 tonne (3$\times$1$\times$1~m$^3$) active mass (volume) Liquid Argon Time-Projection Chamber (TPC) operated in a dual-phase mode. We present a detailed study of…

Instrumentation and Detectors · Physics 2021-04-19 WA105 collaboration

The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr. After successful…

Directional detection of Dark Matter allows for unambiguous direct detection of WIMPs as well as discrimination between various Dark Matter models in our galaxy. The DMTPC detector is a low-pressure TPC with optical readout designed for…

Particle detectors based on liquid argon (LAr) have recently become recognized as an extremely attractive technology for the direct detection of dark matter as well as the measurement of coherent elastic neutrino-nucleus scattering…

Instrumentation and Detectors · Physics 2020-06-03 Cong Guo , Mengyun Guan , Xilei Sun , Weixing Xiong , Peng Zhang , Changgen yang

The aim of the CYGNO project is the construction and operation of a 1~m$^3$ gas TPC for directional dark matter searches and coherent neutrino scattering measurements, as a prototype toward the 100-1000~m$^3$ (0.15-1.5 tons) CYGNUS network…

‹ Prev 1 8 9 10 Next ›