English
Related papers

Related papers: Calibration and GEANT4 Simulations of the Phase II…

200 papers

We describe a novel gaseous detector concept for heavy-ion tracking and imaging: the Optical Parallel-Plate Avalanche Counter (O-PPAC). The detector consists of two thin parallel-plate electrodes separated by a small (typically 3 mm) gap…

Instrumentation and Detectors · Physics 2018-10-17 Marco Cortesi , Yassid Ayyada , John Yurkon

Retinal Optical Coherence Tomography (OCT), a noninvasive cross-sectional scan of the eye with qualitative 3D visualization of the retinal anatomy is use to study the retinal structure and the presence of pathogens. The advent of the…

Image and Video Processing · Electrical Eng. & Systems 2023-02-28 Nchongmaje Ndipenoch , Alina Miron , Zidong Wang , Yongmin Li

We have developed a position-sensitive Parallel Plate Avalanche Counter (PPAC), which has been used as a focal plane detector in the BigRIPS fragment separator and the subsequent RI-beam delivery lines at the RIKEN Nishina Center RI Beam…

Instrumentation and Detectors · Physics 2015-06-17 H. Kumagai , T. Ohnishi , N. Fukuda , H. Takeda , D. Kameda , N. Inabe , K. Yoshida , T. Kubo

A new detector is being developed at the National Superconducting Cyclotron Laboratory (NSCL) to measure low energy charged-particles from beta-delayed particle emission. These low energy particles are very important for nuclear…

Instrumentation and Detectors · Physics 2016-06-27 D. Perez-Loureiro , C. Wrede

A neutron counter designed for assay of radioactive materials has been adapted for beam experiments at TUNL. The cylindrical geometry and 60% maximum efficiency make it well suited for ($\gamma,n$) cross-section measurements near the…

Nuclear Experiment · Physics 2015-03-17 C. W. Arnold , T. B. Clegg , H. J Karwowski , G. C. Rich , J. R. Tompkins , C. R. Howell

We aim to investigate the feasibility of online monitoring of irradiation time (IRT) and scan time for FLASH radiotherapy using a pixelated semiconductor detector. Measurements of the time structure of FLASH irradiations were performed…

To meet the stringent time calibration requirements for the Belle II experiment upgrade, particularly for its large-size KL and Muon Detector comprising tens of thousands of scintillator channels with time resolutions better than 100 ps, we…

Instrumentation and Detectors · Physics 2026-02-23 Ziyu Liu , Xiyang Wang , Shiming Zou , Xiaolong Wang , Junhao Yin , Minggang Zhao

The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make both a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and to probe eV-scale sterile neutrinos by searching for…

Precise and fast prediction methods for ischemic areas comprised of dead tissue, core, and salvageable tissue, penumbra, in acute ischemic stroke (AIS) patients are of significant clinical interest. They play an essential role in improving…

Image and Video Processing · Electrical Eng. & Systems 2023-12-06 Luca Tomasetti , Kjersti Engan , Liv Jorunn Høllesli , Kathinka Dæhli Kurz , Mahdieh Khanmohammadi

Charged particle beams are used in Particle Therapy (PT) to treat oncological patients due to their selective dose deposition in tissues and to their high biological effect in killing cancer cells with respect to photons and electrons used…

A neutron time projection chamber can locate the approximate direction of a neutron hot spot with high efficiency and a 4{\pi} field of view. The angular resolution can be significantly improved by adding several plastic scintillation…

Instrumentation and Detectors · Physics 2019-07-11 Yidong Fu , Yang Tian , Yulan Li , Yigang Yang , Yiming Cai , Jian Yang , Jin Li

We propose a fast beam orientation selection method, based on deep neural networks (DNN), capable of developing a plan comparable to those by the state-of-the-art column generation method. The novelty of Our model lies in its supervised…

Medical Physics · Physics 2019-12-23 Azar Sadeghnejad Barkousaraie , Olalekan Ogunmolu , Steve Jiang , Dan Nguyen

For the in vivo range verification in proton therapy, it has been tried to measure the spatial distribution of the prompt gammas generated by the proton-induced interactions with the close relationship with the proton dose distribution.…

Medical Physics · Physics 2015-03-13 Wook-Geun Shin , Chul Hee Min , Jae-Ik Shin , Jong Hwi Jeong , Se Byeong Lee

Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols, and the development or assessment of image reconstruction algorithms…

Stereotactic body radiation therapy (SBRT) and hypofractionation using pencil-beam scanning (PBS) proton therapy (PBSPT) is an attractive option for thoracic malignancies. Combining the advantages of target coverage conformity and critical…

Objective: To assess the accuracy and computational performance of a stochastic differential equation (SDE)--based model for proton beam dose calculation by benchmarking against Geant4 in simplified phantom geometries. Approach: Building on…

A novel data-processing method was developed to facilitate scintillation detector characterization. Combined with fan-beam calibration, this method can be used to quickly and conveniently calibrate gamma-ray detectors for SPECT, PET,…

Instrumentation and Detectors · Physics 2021-06-24 Xin Li , Li Tao , Craig S. Levin , Lars R. Furenlid

Fully convolutional networks (FCNs), including UNet and VNet, are widely-used network architectures for semantic segmentation in recent studies. However, conventional FCN is typically trained by the cross-entropy or Dice loss, which only…

Image and Video Processing · Electrical Eng. & Systems 2021-01-26 Kelei He , Chunfeng Lian , Ehsan Adeli , Jing Huo , Yang Gao , Bing Zhang , Junfeng Zhang , Dinggang Shen

Purpose: Dual-energy CT (DECT) has been used to derive relative stopping power (RSP) map by obtaining the energy dependence of photon interactions. The DECT-derived RSP maps could potentially be compromised by image noise levels and the…

Transforming the resistive plate chambers from charged-particle into gamma-quanta detectors opens the way towards their application as a basic element of a hybrid imaging system, which combines positron emission tomography (PET) with…

Instrumentation and Detectors · Physics 2015-06-12 Georgi Georgiev , Nevena Ilieva , Venelin Kozhuharov , Iglika Lessigiarska , Leandar Litov , Borislav Pavlov , Peicho Petkov
‹ Prev 1 8 9 10 Next ›