Related papers: Model Checking Implantable Cardioverter Defibrilla…
A Cardiac Implantable Medical device (IMD) is a device, which is surgically implanted into a patient's body, and wirelessly configured using an external programmer by prescribing physicians and doctors. A set of lethal attacks targeting…
Ventricular Fibrillation (VF) is a malignant cardiac arrhythmia and the leading cause of sudden cardiac death, characterized by disorganized, high-frequency ventricular activity that results in the rapid loss of coordinated pump function…
This paper investigates the impact of implantable cardioverter defibrillator (ICD)'s load on its lithium battery power sources through a coupled electro-thermal dynamic model simulation. ICDs are one of the effective treatments available to…
Ventricular fibrillation, the major reason behind sudden cardiac death, is turbulent cardiac electrical activity in which rapid, irregular disturbances in the spatiotemporal electrical activation of the heart makes it incapable of any…
Virtual heart models have been proposed to enhance the safety of implantable cardiac devices through closed loop validation. To communicate with a virtual heart, devices have been driven by cardiac signals at specific sites. As a result,…
Virtual studies of ICD behaviour are crucial for testing device functionality in a controlled environment prior to clinical application. Although previous works have shown the viability of using in silico testing for diagnosis, there is a…
Ventricular Fibrillation (VF), one of the most dangerous arrhythmias, is responsible for sudden cardiac arrests. Thus, various algorithms have been developed to predict VF from Electrocardiogram (ECG), which is a binary classification…
Life-threatening ventricular arrhythmias (VA) are the leading cause of sudden cardiac death (SCD), which is the most significant cause of natural death in the US. The implantable cardioverter defibrillator (ICD) is a small device implanted…
An Implantable Cardioverter Defibrillator (ICD) is a medical device used for the detection of potentially fatal cardiac arrhythmia and their treatment through the delivery of electrical shocks intended to restore normal heart rhythm. An ICD…
The heart is a vital organ that relies on the orchestrated propagation of electrical stimuli to coordinate each heart beat. Abnormalities in the heart's electrical behaviour can be managed with a cardiac pacemaker. Recently, the closed-loop…
Background: One of the common causes of sudden cardiac death (SCD) in young people is hypertrophic cardiomyopathy (HCM) and the primary prevention of SCD is with an implantable cardioverter defibrillators (ICD). Concerning the incidence of…
Electrical analogy (Lumped method) is an easy way to model human cardiovascular system. In this paper Lumped method is used for simulating a complete model. It describes a 36-vessel model and cardiac system of human body with details that…
The purpose of this study is to optimize the selection of prophylactic cardioverter defibrillator implantation candidates. Currently, the main criterion for implantation is a low Left Ventricular Ejection Fraction (LVEF) whose specificity…
Many types of ventricular and atrial cardiac arrhythmias have been discovered in clinical practice in the past 100 years, and these arrhythmias are a major contributor to sudden cardiac death. Ventricular tachycardia, ventricular…
We developed a novel patient-specific computational model for the numerical simulation of ventricular electromechanics in patients with ischemic cardiomyopathy (ICM). This model reproduces the activity both in sinus rhythm (SR) and in…
Left ventricular assist devices (LVADs) can provide mechanical support for a failing heart as bridge to transplant and destination therapy. Physiological control systems for LVADs should be designed to respond to changes in hemodynamic…
Embedded systems are everywhere, from home appliances to critical systems such as medical devices. They usually have associated timing constraints that need to be verified for the implementation. Here, we use an untimed bounded model…
BACKGROUND. The clinical effectiveness of primary prevention implantable cardioverter defibrillator (ICD) therapy is under debate. It is urgently needed to better identify patients who benefit from prophylactic ICD therapy. The EUropean…
Myocardial infarction (MI), commonly known as a heart attack, is a critical health condition caused by restricted blood flow to the heart. Early-stage detection through continuous ECG monitoring is essential to minimize irreversible damage.…
To prevent sudden cardiac death, predicting where in the cardiac system an order-disorder phase transition into ventricular fibrillation begins is as important as when it begins. We present a computationally efficient, information-theoretic…