We report on a measurement of the absorption length of scintillation light in liquid argon due to dissolved nitrogen at the part-per-million (ppm) level. We inject controlled quantities of nitrogen into a high purity volume of liquid argon…

Instrumentation and Detectors · Physics 2015-06-16 B. J. P. Jones , C. S. Chiu , J. M. Conrad , C. M. Ignarra , T. Katori , M. Toups

The ionization signals in the liquid argon of the ATLAS electromagnetic calorimeter are studied in detail using cosmic muons. In particular, the drift time of the ionization electrons is measured and used to assess the intrinsic uniformity…

Instrumentation and Detectors · Physics 2015-05-18 The ATLAS Collaboration

An analytical model has been developed to map out the low-pressure (left-hand) branch of the Paschen curve at very high voltage when electrons are in the runaway regime and charge exchange/ionization avalanche by ions and fast neutral atoms…

Plasma Physics · Physics 2018-04-11 Liang Xu , Alexander V. Khrabrov , Igor D. Kaganovich , Timothy J. Sommerer

In this paper we describe the design, construction, and operation of a first large area double-phase liquid argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). The detector has a maximum drift length of 60 cm and the…

A model is described, in which electrical breakdown in high-voltage systems is caused by stochastic fluctuations of the mobile dislocation population in the cathode. In this model, the mobile dislocation density normally fluctuates, with a…

Accelerator Physics · Physics 2019-09-05 Eliyahu Zvi Engelberg , Ayelet Badichi Yashar , Yinon Ashkenazy , Michael Assaf , Inna Popov

Using a relaxation oscillator circuit, breakdown ($V_{\mathrm{BD}}$) and quench ($V_{\mathrm{Q}}$) voltages of a DC discharge microplasma between two needle probes are measured. High resolution modified Paschen curves are obtained for argon…

Plasma Physics · Physics 2015-02-12 Ebrahim Forati , Shiva Piltan , Dan Sievenpiper

Measurement of a non-zero electric dipole moment (EDM) of the electron within a few orders of magnitude of the current best limit of |d_e| < 1.05 e -27 e cm would be an indication of physics beyond the Standard Model. The ACME Collaboration…

High-harmonic spectroscopy (HHS) is a nonlinear all-optical technique with inherent attosecond temporal resolution, which has been applied successfully to a broad variety of systems in the gas phase and solid state. Here, we extend HHS to…

The kinetic performance of graphite particles is difficult to deconvolute from half-cell experiments, where the influences of the working electrode porosity and the counter electrode contribute nonlinearly to the electrochemical re-sponse.…

Materials Science · Physics 2015-03-13 Michael Heß , Petr Novák

The spectral and temporal light emission properties of liquid argon have been studied in the context of its use in large liquid rare-gas detectors for detecting Dark Matter particles in astronomy. A table-top setup has been developed.…

Instrumentation and Detectors · Physics 2015-11-25 T. Heindl , T. Dandl , A. Fedenev , M. Hofmann , R. Krücken , L. Oberauer , W. Potzel , J. Wieser , A. Ulrich

High quality electron beams, with high spatial and tempo- ral resolution, have an important use in electron diffraction experiments to probe and study the constituents of matter. A cold electron source is being developed based on elec- tron…

Accelerator Physics · Physics 2015-05-12 R Appleby , W. Bertsche , M. Harvey , M. Jones , B. Kyle , O. Mete , A. Murray , G. Xia

Conditioning of a metal structure in a high-voltage system is the progressive development of resistance to vacuum arcing over the operational life of the system. This is, for instance, seen during the initial operation of radio frequency…

In this paper we analyze the problem of glow discharge in low pressure plasma in industrial plant, for chambers of different shapes and various working parameters, like pressure and electric potential. The model described is based upon a…

The axial light distributions in parallel-plate dc microdischarges in argon show similar behavior to large scale discharges. Between the low-current Townsend mode and the high current glow mode exists a large region of currents where…

Plasma Physics · Physics 2015-05-28 T. Kuschel , N. Škoro , D. Marić , I. Stefanović , G. Malović , J. Winter , Z. Lj. Petrović

Formation mechanisms of striations along the discharge channel of a single-filament dielectric barrier discharge (DBD) in argon at atmospheric pressure are investigated by means of a time-dependent, spatially two-dimensional fluid-Poisson…

Liquid argon detectors are ubiquitous in particle, astroparticle, and applied physics. They reached an unprecedented level of maturity thanks to more than 20 years of R&D and the operation of large-scale facilities at CERN, Fermilab, and…

Instrumentation and Detectors · Physics 2024-10-30 W. M. Bonivento , F. Terranova

Understanding the underlying factors responsible for higher-than-anticipated local field enhancements that trigger vacuum breakdown on pristine metal surfaces is crucial for the development of devices capable of withstanding intense…

Mesoscale and Nanoscale Physics · Physics 2024-03-19 Soumendu Bagchi , Evgenya Simakov , Danny Perez

We present a review of the current experimental and theoretical understanding of electron transport in noble liquids. Special attention is given to recent measurements that coincide with the development of time projection chambers (TPCs)…

Applied Physics · Physics 2025-04-24 G. J. Boyle , N. A. Garland , D. L. Muccignat , I. Simonović , D. Bošnjaković , S. Dujko , R. D. White

The low-noise operation of readout electronics in a liquid argon time projection chamber (LArTPC) is critical to properly extract the distribution of ionization charge deposited on the wire planes of the TPC, especially for the induction…

Instrumentation and Detectors · Physics 2023-02-17 MicroBooNE collaboration , R. Acciarri , C. Adams , R. An , J. Anthony , J. Asaadi , M. Auger , L. Bagby , S. Balasubramanian , B. Baller , C. Barnes , G. Barr , M. Bass , F. Bay , M. Bishai , A. Blake , T. Bolton , B. Bullard , L. Camilleri , D. Caratelli , B. Carls , R. Castillo Fernandez , F. Cavanna , H. Chen , E. Church , D. Cianci , E. Cohen , G. H. Collin , J. M. Conrad , M. Convery , J. I. Crespo-Anadon , G. De Geronimo , M. Del Tutto , D. Devitt , S. Dytman , B. Eberly , A. Ereditato , L. Escudero Sanchez , J. Esquivel , A. A. Fadeeva , B. T. Fleming , W. Foreman , A. P. Furmanski , D. Garcia-Gamez , G. T. Garvey , V. Genty , D. Goeldi , S. Gollapinni , N. Graf , E. Gramellini , H. Greenlee , R. Grosso , R. Guenette , A. Hackenburg , P. Hamilton , O. Hen , V Hewes , C. Hill , J. Ho , G. Horton-Smith , A. Hourlier , E. -C. Huang , C. James , J. Jan de Vries , C. -M. Jen , L. Jiang , R. A. Johnson , J. Joshi , H. Jostlein , D. Kaleko , G. Karagiorgi , W. Ketchum , B. Kirby , M. Kirby , T. Kobilarcik , I. Kreslo , A. Laube , S. Li , Y. Li , A. Lister , B. R. Littlejohn , S. Lockwitz , D. Lorca , W. C. Louis , M. Luethi , B. Lundberg , X. Luo , A. Marchionni , C. Mariani , J. Marshall , D. A. Martinez Caicedo , V. Meddage , T. Miceli , G. B. Mills , J. Moon , M. Mooney , C. D. Moore , J. Mousseau , R. Murrells , D. Naples , P. Nienaber , J. Nowak , O. Palamara , V. Paolone , V. Papavassiliou , S. F. Pate , Z. Pavlovic , E. Piasetzky , D. Porzio , G. Pulliam , X. Qian , J. L. Raaf , V. Radeka , A. Rafique , S. Rescia , L. Rochester , C. Rudolf von Rohr , B. Russell , D. W. Schmitz , A. Schukraft , W. Seligman , M. H. Shaevitz , J. Sinclair , A. Smith , E. L. Snider , M. Soderberg , S. Soldner-Rembold , S. R. Soleti , P. Spentzouris , J. Spitz , J. St. John , T. Strauss , A. M. Szelc , N. Tagg , K. Terao , M. Thomson , C. Thorn , M. Toups , Y. -T. Tsai , S. Tufanli , T. Usher , W. Van De Pontseele , R. G. Van de Water , B. Viren , M. Weber , D. A. Wickremasinghe , S. Wolbers , T. Wongjirad , K. Woodruff , T. Yang , L. Yates , B. Yu , G. P. Zeller , J. Zennamo , C. Zhang

In the near future there will be the request for very large liquid Xenon (LXe) detectors for Dark Matter (DM) searches in the 50-ton range. To avoid an impractically long, single drift space of a dual-phase detector, it seems beneficial to…

Instrumentation and Detectors · Physics 2021-09-01 P. Juyal , K. L. Giboni , X. Ji , J. Liu