Related papers: Optical Gravitational Wave Antenna with Increased …
We analyze the electromagnetic fields in a Pound-Drever-Hall locked, marginally unstable, Fabry-Perot cavity as a function of small changes in the cavity length during resonance. More specifically, we compare the results of a detailed…
In order to expand the astrophysical reach of gravitational wave detectors, several interferometer topologies have been proposed to evade the thermodynamic and quantum mechanical limits in future detectors. In this work, we make a…
LIGO, the Laser Interferometer Gravitational-wave Observatory, has been designed and constructed to measure gravitational wave strain via differential arm length. The LIGO 4-km Michelson arms with Fabry-Perot cavities have auxiliary length…
Michelson-type laser-interferometric gravitational-wave (GW) observatories employ very high light powers as well as transmissively- coupled Fabry-Perot arm resonators in order to realize high measurement sensitivities. Due to the absorption…
We propose two detuned Fabry-Perot cavities, each pumped through both the mirrors, positioned in line as a toy model of the gravitational-wave (GW) detector free from displacement noise of the test masses. It is demonstrated that the noise…
A universal amplification scheme of ultra-small phase based on weak measurements is given and a weak measurements amplification based laser interferometer gravitational-wave observatory (WMA-LIGO) is suggested. The WMA-LIGO has potential to…
Three-mode parametric instability is a threat to attaining design power levels in Advanced gravitational wave detectors. The first observation of three-mode parametric instability in a long optical cavity revealed that instabilities could…
We develop here algorithms which allow to find regimes of signal-recycled Fabry-Perot--Michelson interferometer (for example, Advanced LIGO), optimized concurrently for two (binary inspirals + bursts) and three (binary inspirals + bursts +…
The sensitivity of next-generation gravitational-wave detectors such as Advanced LIGO and LCGT should be limited mostly by quantum noise with an expected technical progress to reduce seismic noise and thermal noise. Those detectors will…
Optical rigidity in aLIGO gravitational-wave detector, operated on dark port regime, is unstable. We show that the same interferometer with excluded symmetric mechanical mode but with unbalanced arms allows to get stable optical spring for…
Long-storage-time Fabry-Perot cavities are a core component of many precision measurement experiments. Optical loss in such cavities is a critical parameter in determining their performance; however, it is very difficult to determine a…
We demonstrate micromechanical reflectors with a reflectivity as large as 99.4% and a mechanical quality factor Q as large as 7.8*10^5 for optomechanical applications. The reflectors are silicon nitride membranes patterned with…
The 2nd generation VLTI instrument GRAVITY is a two-field infrared interferometer operating in the K band between 1.97 and 2.43 $\mu$m with either the four 8 m or the four 1.8 m telescopes of the Very Large Telescope (VLT). Beams collected…
In the quest to develop viable designs for third-generation optical interferometric gravitational-wave detectors (e.g., LIGO-III and EURO), one strategy is to monitor the relative momentum or speed of the test-mass mirrors, rather than…
Large Fabry-Perot Interferometers are used in a variety of astronomical instrumentation, including spectro-polarimeters for 4-meter class solar telescopes. In this work we comprehensively characterize the cavity of a prototype 150 mm…
We analyze the interaction of plane '+'-polarized gravitational waves with a Fabry-Perot cavity in the local Lorentz frame of the cavity input mirror outside of the range of long-wave approximation with the force of radiation pressure taken…
We measure the motional fluctuations of a micromechanical mirror using a Michelson interferometer, and demonstrate its interferometric stability. The position stability of the micromirror is dominated by the thermal mechanical noise of the…
Recent researches show that the fluctuations of the dielectric mirrors coating thickness can introduce a substantial part of the future laser gravitational-wave antennae total noise budget. These fluctuations are especially large in the…
We present a fiber-diffraction interferometer using a coherent fiber optic taper for optical testing in an uncontrolled environment. We use a coherent fiber optic taper and a single-mode fiber having thermally-expanded core. Part of the…
Diffraction gratings have been proposed as core elements in future laser-interferometric gravitational-wave detectors. In this paper, we use a steady-state technique to derive coupling of lateral grating displacement to the output ports of…