Related papers: Energy calibration via correlation
The wavelength calibration of spectrographs is an essential but challenging task in many disciplines. Calibration is traditionally accomplished by imaging the spectrum of a light source containing features that are known to appear at…
The high frequency primary power standard is univocally realized by means of a coaxial microcalorimeter, at least up to 40 GHz. The coaxial microcalorimeter is a broadband measurement system adjusted for effec-tive efficiency measurement of…
The inductive charging of electric vehicles requires specific measurement and calibration systems. In fact, the measurement of power on board involves DC signals, which are superimposed to a significant AC ripple up to or over 150 kHz,…
A method for measurement of energy of high-energy particles by a thin calorimeter, is presented. The method is based on the correlation analysis of dependence of number of secondary particles, $N_e$, at observation level and the relation of…
Monoenergetic photons from a pulsed laser diode or LED are commonly used to calibrate the detector response of high-resolution calorimetric detectors. However, when the detector's resolution is larger than the energy of a single photon, a…
This paper presents a novel centralized, variational data assimilation approach for calibrating transient dynamic models in electrical power systems, focusing on load model parameters. With the increasing importance of inverter-based…
A parameter method is introduced in order to estimate the relationship among the various variables of a system in equilibrium, where the potential energy functions are incompletely known or the quantum mechanical calculations very…
The thermal sensitive electrical parameter (TSEP) method is crucial for enhancing the reliability of power devices through junction temperature monitoring. The TSEP method comprises three key processes: calibration, regression, and…
Verifying entanglement with experimental measurements requires that we take the limitations of experimental techniques into account, while still proving that the data obtained could not have been generated from a classical source. In the…
Semiconductor detectors made of CdTe crystal have high gamma-ray detection efficiency and are usable at room temperature. However, the energy resolution of CdTe detectors for MeV gamma-rays is rather poor because of the significant hole…
Transition edge sensor microcalorimeters can measure x-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future x-ray observatories, each…
CMS calorimeter energy calibration was done in the full CMS simulated geometry for the pseudorapidity region eta = 0. The samples of single pion events were generated with a set of incident energies from 10 GeV to 3 TeV. The analysis of the…
In the scaling development of quantum computers, the calibration process emerges as a critical challenge. Existing calibration methods, utilizing the same pulse waveform for two-qubit gates across the device, overlook hardware differences…
Pulsed UV lasers can provide useful "testbeams" for observatories that use optical detectors, especially fluorescence detectors, to measure high energy cosmic-rays. The light observed by the detector is proportional to the energy of the…
The complexity and accuracy of current and future precision cosmology observational campaigns has made it essential to develop an efficient technique for directly combining simulation and observational datasets to determine cosmological and…
Buildings rarely perform as designed/simulated and and there are numerous tangible benefits if this gap is reconciled. A new scientific yet pragmatic methodology - called Enhanced Parameter Estimation (EPE) - is proposed that allows…
A new method for calibrating the hadron response of a segmented calorimeter is developed and successfully applied to beam test data. It is based on a principal component analysis of energy deposits in the calorimeter layers, exploiting…
The correlated behavior of electrons determines the structure and optical properties of molecules, semiconductor and other systems. Valuable information on these correlations is provided by measuring the response to femtosecond laser…
This article presents a method that uses turn-by-turn beam position data and k-modulation data to measure the calibration factors of beam position monitors in high energy accelerators. In this method, new algorithms have been developed to…
This paper presents the electron and photon energy calibration obtained with the ATLAS detector using 140 fb$^{-1}$ of LHC proton-proton collision data recorded at $\sqrt{s}=13$ TeV between 2015 and 2018. Methods for the measurement of…