English
Related papers

Related papers: Attenuation of vacuum ultraviolet light in liquid …

200 papers

The attenuation of vacuum ultraviolet light in liquid argon in the context of its application in large liquid noble gas detectors has been studied. Compared to a previous publication several technical issues concerning transmission…

Instrumentation and Detectors · Physics 2015-11-25 A. Neumeier , T. Dandl , A. Himpsl , M. Hofmann , L. Oberauer , W. Potzel , S. Schönert , A. Ulrich

Results of transmission experiments of vacuum ultraviolet light through a 11.6 cm long cell filled with pure and xenon-doped liquid argon are described. Pure liquid argon shows no attenuation down to the experimental short-wavelength…

Instrumentation and Detectors · Physics 2015-11-25 A. Neumeier , T. Dandl , A. Himpsl , L. Oberauer , W. Potzel , S. Schönert , A. Ulrich

A spectroscopic study of liquid argon from the vacuum ultraviolet at 110 nm to 1000 nm is presented. Excitation was performed using continuous and pulsed 12 keV electron beams. The emission is dominated by the analogue of the so called 2nd…

Instrumentation and Detectors · Physics 2015-11-25 T. Heindl , T. Dandl , M. Hofmann , R. Krücken , L. Oberauer , W. Potzel , J. Wieser , A. Ulrich

We report on a measurement of the absorption length of scintillation light in liquid argon due to dissolved nitrogen at the part-per-million (ppm) level. We inject controlled quantities of nitrogen into a high purity volume of liquid argon…

Instrumentation and Detectors · Physics 2015-06-16 B. J. P. Jones , C. S. Chiu , J. M. Conrad , C. M. Ignarra , T. Katori , M. Toups

Vacuum ultraviolet light emission from xenon-doped liquid argon is described in the context of liquid noble gas particle detectors. Xenon concentrations in liquid argon from 0.1 ppm to 1000 ppm were studied. The energy transfer from the…

Instrumentation and Detectors · Physics 2015-11-25 A. Neumeier , T. Dandl , T. Heindl , A. Himpsl , L. Oberauer , W. Potzel , S. Roth , S. Schönert , J. Wieser , A. Ulrich

We report on a measurement of the attenuation length for the scintillation light in the tonne size liquid argon target of the ArDM dark matter experiment. The data was recorded in the first underground operation of the experiment in…

The propagation velocity of scintillation light in liquid argon $v_{g}$ at $\lambda \sim 128$~nm wavelength, has been measured for the first time in a dedicated experimental setup at CERN.\\ The obtained result $\frac{1}{v_{g}} = 7.46 \pm…

Instrumentation and Detectors · Physics 2021-07-30 M. Babicz , S. Bordoni , A. Fava , U. Kose , M. Nessi , F. Pietropaolo , G. L. Raselli , F. Resnati , M. Rossella , P. Sala , F. Stocker , A. Zani

The possibility of efficient collection and detection of vacuum ultraviolet light as emitted by argon, krypton, and xenon gas is studied. Absolute quantum efficiencies of large area avalanche photodiodes (LAAPDs) are derived at these…

Instrumentation and Detectors · Physics 2016-11-15 R. Chandrasekharan , A. Knecht , M. Messina , C. Regenfus , A. Rubbia

The scintillation light of liquid argon has been recorded wavelength and time resolved with very good statistics in a wavelength interval ranging from 118 nm through 970 nm. Three different ion beams, protons, sulfur ions and gold ions,…

Instrumentation and Detectors · Physics 2015-11-25 M. Hofmann , T. Dandl , T. Heindl , A. Neumeier , L. Oberauer , W. Potzel , S. Roth , S. Schönert , J. Wieser , A. Ulrich

We report the measurement of longitudinal electron diffusion coefficients in liquid argon for electric fields between 100 and 2000 V/cm with a gold photocathode as a bright electron source. The measurement principle, apparatus, and data…

The absorption length, $\lambda_{abs}$, of light with wavelengths between 0.95 and 1.30$~\mu$m in silicon irradiated with 24$~$GeV/c protons to 1$~$MeV neutron equivalent fluences between 0 and $8.6 \times 10^{15}~$cm$^{-2}$ has been…

Instrumentation and Detectors · Physics 2020-04-21 C. Scharf , F. Feindt , R. Klanner

Liquid argon is used as active medium in a variety of neutrino and Dark Matter experiments thanks to its excellent properties of charge yield and transport and as a scintillator. Liquid argon scintillation photons are emitted in a narrow…

Instrumentation and Detectors · Physics 2021-02-10 Ettore Segreto

The attenuation of the electron shower size beyond the shower maximum is studied with the KASCADE extensive air shower experiment in the primary energy range of about $10^{14}-10^{16}$ eV. Attenuation and absorption lengths are determined…

Astrophysics · Physics 2019-08-14 T. Antoni

Inert (noble gas) elements are extremely inactive to surrounding chemical environment and are frequently employed as protective gas in various semiconductor fabrication processes. In this work, we surprisingly discover that high doses of…

Materials Science · Physics 2024-06-11 Nian-Ke Chen , Yu-Chen Gao , Ji-Hong Zhao , Chun-Hao Li , Qi-Dai Chen , Hong-Bo Sun , Shengbai Zhang , Xian-Bin Li

We performed a time-resolved spectroscopic study of the VUV/UV argon scintillation as a function of pressure and electric field, by means of a wavelength sensitive detector operated with different radioactive sources. Our work conveys new…

In this paper we present results on measurements of the dielectric strength of liquid argon near its boiling point and cathode-anode distances in the range of 0.1 mm to 40 mm with spherical cathode and plane anode. We show that at such…

Instrumentation and Detectors · Physics 2014-11-18 A. Blatter , A. Ereditato , C. -C. Hsu , S. Janos , I. Kreslo , M. Luethi , C. Rudolf von Rohr , M. Schenk , T. Strauss , M. S. Weber , M. Zeller

Measuring the scintillation light in noble gases is an important detection technique in particle physics. Numerous rare event searches like neutrino beam experiments, neutrino-less double beta-decay, and dark matter searches use argon-based…

Instrumentation and Detectors · Physics 2022-07-20 D. E. Fields , and R. Gibbons M. Gold , N. McFadden , S. R. Elliott , R. Massarczyk

We obtained laboratory spectra of absorption by water vapor at the wavelengths 6500-10500 {\AA} with the multipass cell. The water vapor content along the line of view varied from 0.1 to 3.0 cm of precipitated water, the pressure from 0.1…

Instrumentation and Methods for Astrophysics · Physics 2010-10-26 G. A. Alekseeva , V. D. Galkin , I. B. Sal'nikov

We measure the liquid argon scintillation response to electronic recoils in the energy range of $2.82$ to $1274.6~{\rm keV}$ at null electric field. The single-phase detector with a large optical coverage used in this measurement yields…

Instrumentation and Detectors · Physics 2020-11-25 M. Kimura , K. Aoyama , M. Tanaka , K. Yorita
‹ Prev 1 2 3 10 Next ›