Related papers: Testing Hadronic Interaction Models using a Highly…
The FoCal is a high-granularity forward calorimeter to be installed as an ALICE upgrade subsystem during the LHC Long Shutdown 3 and take data during the LHC Run 4. The FoCal detector, covering a pseudorapidity interval of $3.2 < \eta <…
A Forward Calorimeter (FoCal) has been proposed as part of the ALICE upgrades for data taking from 2029 onwards. The FoCal will feature a sampling electromagnetic calorimeter segmented into 110 towers supplemented by a hadron calorimeter.…
The forward calorimeter (FoCal) of ALICE, planned to be operational for LHC Run 4, will cover the pseudorapidity range 3.4 $ \leq \eta \leq $ 5.8 allowing to probe the unexplored region of Bjorken-x down to $10^{-6}$. The hadronic section…
The high granularity of the CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) provides the capability to reveal the track segments present in hadronic showers. These segments are then used as a tool to probe the behaviour of the active…
Electron-positron ($e^+e^-$) collisions provide a clean environment for precision tests of Quantum Chromodynamics (QCD) due to the absence of hadronic initial-state effects. We present a novel analysis of archived ALEPH data from the Large…
Under the influence of standardly used description of Coulomb-hadronic interference proposed by West and Yennie the protons have been interpreted as transparent objects; elastic events have been interpreted as more central than inelastic…
The studies presented in this paper provide a first experimental test of the Particle Flow Algorithm (PFA) concept using data recorded in high granularity calorimeters. Pairs of overlaid pion showers from CALICE 2007 test beam data are…
Hadronic resonances $\mathrm{K}^{*}(892)^{0}$, $\phi$(1020) and $\Sigma(1385)^{\pm}$ have been measured by the ALICE experiment in pp collisions at $\sqrt{s}=7$ TeV and in Pb-Pb collisions at $\sqrt{s_{_\mathrm{NN}}}=2.76$ TeV. Transverse…
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a…
This paper presents the design and optimization of a LYSO crystal electromagnetic calorimeter (ECAL) for the DarkSHINE experiment, which aims to search for dark photons as potential mediators of dark forces. The ECAL design was evaluated…
Precision physics at future colliders requires highly granular calorimeters to support the Particle Flow Approach for event reconstruction. This article presents a review of about 10 - 15 years of R\&D, mainly conducted within the CALICE…
The ALICE detector at the LHC (A Large Ion Collider Experiment) will carry out comprehensive measurements of high energy nucleus-nucleus collisions, in order to study QCD matter under extreme conditions and the phase transtion between…
The operation and performance of the Compact Muon Solenoid (CMS) electromagnetic calorimeter (ECAL) are presented, based on data collected in pp collisions at $\sqrt{s}$ = 13 TeV at the CERN LHC, in the years from 2015 to 2018 (LHC Run 2),…
Calorimeters for particle physics experiments with integration time of a few ns will substantially improve the capability of the experiment to resolve event pileup and to reject backgrounds. In this paper the time development of hadronic…
We report on several versions of the calibration and monitoring system dedicated to scintillator tile calorimeters built within the CALICE collaboration and intended for future linear collider experiments. Whereas the first, a 1 m3 analogue…
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the…
The Forward Calorimeter (FoCal) is a new sub-detector in ALICE to be installed during the LHC Long Shutdown 3 for LHC Run 4. It consists of a highly-granular Si+W electromagnetic calorimeter combined with a conventional metal-scintillator…
We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super…
The production of direct photons, not coming from hadron decays, at large transverse momentum pT > 2 GeV/c in proton-proton collisions at the LHC, is an interesting process to test the predictions of perturbative Quantum Chromodynamics at…
As a future Higgs or Z factory, construction of the circular electron positron collider(CEPC) has been proposed to precisely measure Higgs bosons. A particle flow-oriented electromagnetic calorimeter (ECAL) and a hadronic calorimeter…