Related papers: 100ps time resolution with thin silicon pixel dete…
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of…
The discovery potential for charged Higgs bosons has been studied including background simulations for sqrts = 500 GeV and a luminosity of 10 fb-1 depending on the hadronic calorimeter resolution of a LC500 detector. The hadronic decay…
We give a short compendium of the main ongoing detectors and concepts capable of performing accurate sub-100 ps timing at high particle fluxes and on large areas, through technologies based on gaseous media. We briefly discuss the…
We present an innovative charge detector with high resolution and wide dynamic range designed to fulfill the requirements of a monitoring system for a high energy ion beam. The detector prototype, constructed using Si photodiodes and a…
In the context of the CERN EP R&D on monolithic sensors and the ALICE ITS3 upgrade, the Tower Partners Semiconductor Co (TPSCo) 65 nm process has been qualified for use in high energy physics, and adopted for the ALICE ITS3 upgrade. An…
A muon tracking system consisting of four 9cm x 10cm sized bulk Micromegas detectors with 128um amplification-gap and two 10cm x 10cm triple GEM detectors is foreseen for high-precision tracking of 140GeV muons at the H8 beamline at CERN…
When testing and calibrating particle detectors in a test beam, accurate tracking information independent of the detector being tested is extremely useful during the offline analysis of the data. A general-purpose Silicon Beam Tracker (SBT)…
Silicon carbide detectors exhibit good detection performance and are being considered for detection applications. However, the presence of surface electrode of detector limits the application of low-penetration particle detectors,…
We describe a superconducting transition edge sensor based on a nanoscale niobium detector element. This device is predicted to be capable of energy-resolved near-IR single-photon detection with a GHz count rate. The increased speed and…
The Compact Muon Solenoid (CMS) detector at the CERN Large Hadron Collider (LHC) is undergoing an extensive Phase II upgrade program to prepare for the challenging conditions of the High-Luminosity LHC (HL-LHC). A new timing layer is…
Single-photon detection with high efficiency, high timing resolution, low dark counts and high photon detection-rates is crucial for a wide range of optical measurements. Although efficient detectors have been reported before, combining all…
A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E$\times$B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in…
The high energy physics community has recently identified an $e^+e^-$ Higgs factory as one of the next-generation collider experiments, following the completion of the High Luminosity LHC program at CERN.The moderate radiation levels…
The quadrant silicon detector, a kind of passivated implanted planar silicon detector with quadrant structure on the junction side, gained its wide application in charged particle detection. In this paper, the manufacturing procedure,…
The TT-PET collaboration is developing an MRI-compatible small animal PET scanner in which the sensitive element is a monolithic silicon pixel ASIC targeting 30 ps RMS time resolution. The photon-detection technique is based on a stack of…
A novel graphene-optimized silicon carbide PIN detector was fabricated. Its electrical properties, charge collection performance and signal rise time were evaluated under non-irradiated conditions and under X-ray irradiation with an energy…
The silicon pixel detector (SPD) of the ALICE experiment in preparation at the Large Hadron Collider (LHC) at CERN is designed to provide the precise vertex reconstruction needed for measuring heavy flavor production in heavy ion collisions…
We report on the characterization of four Teledyne Imaging Systems HAWAII Hybrid Si CMOS detectors designed for X-ray detection. Three H1RG detectors were studied along with a specially configured H2RG. Read noise measurements were…
The planned HL-LHC (High Luminosity LHC) in 2025 is being designed to maximise the physics potential through a sizable increase in the luminosity up to 6*10^34 cm^-2 s^-1. A consequence of this increased luminosity is the expected radiation…
DEPFET pixel detectors are unique devices in terms of energy and spatial resolution because very low noise (ENC = 2.2e at room temperature) operation can be obtained by implementing the amplifying transistor in the pixel cell itself. Full…