English
Related papers

Related papers: Fermilab Muon Campus g-2 Cryogenic Distribution Re…

200 papers

An interlock system has been designed for the Fermilab Cryo-module Test Stand (CMTS), a test bed for the cryomodules to be used in the upcoming Linac Coherent Light Source 2 (LCLS-II) project at SLAC. The interlock system features 8…

Accelerator Physics · Physics 2017-05-02 T. Petersen , J. S. Diamond , D. McDowell , D. Nicklaus , P. S. Prieto , A. Semenov

The Muon g-2 experiment E989 at Fermilab measures the anomalous magnetic moment of the muon $a_\mu$ with improved precision compared to the Brookhaven (E821) experiments. The Brookhaven results are in tension with the Standard Model by more…

High Energy Physics - Experiment · Physics 2022-02-24 Alexander Tewsley-Booth

The current $\sim3.5\sigma$ discrepancy between the experimental measurement and theoretical prediction of the muon magnetic anomaly, $a_{\mu}$, stands as a potential indication of the existence of new physics. The Muon $g-2$ experiment at…

High Energy Physics - Experiment · Physics 2019-07-24 Alexander Keshavarzi

The Proton Improvement Plan II (PIPII) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beams for neutrino production. The Linac requires cooling at 80 K, 5 K, and 2 K temperatures, which will…

Accelerator Physics · Physics 2022-06-23 Ashish Kumar Shukla , Andrew Dalesandro , Ram Dhuley , William Soyars

A new experimental area designed to develop, test and verify muon ionization cooling apparatus using the 400-MeV Fermilab Linac proton beam has been fully installed and is presently being commissioned. Initially, this area was used for…

The Muon-to-Electron (Mu2e) experiment at Fermilab, will seek the evidence of direct muon to electron conversion at the sensitivity level where it cannot be explained by the Standard Model. An 8-GeV 25-kW proton beam will be directed onto a…

Accelerator Physics · Physics 2012-02-20 V. S. Pronskikh , V. V. Kashikhin , N. V. Mokhov

The Full Flow Purifier for Fermilab's Muon Campus uses a charcoal bed surrounded by a liquid nitrogen jacket to purify up to 240 g/s of helium gas. Fabrication by Ability Engineering Technology Inc. has been completed and the purifier…

Accelerator Physics · Physics 2025-09-23 J. Subedi , T. Tope , B. Hansen , M. White , J. Tillman , V. Patel , W. Cyko , J. Dong

This paper describes the cryogenic system for the Cryomodule Test Stand (CMTS) at the new Cryomodule Test Facility (CMTF) located at Fermilab. CMTS is designed for production testing of the 1.3 GHz and 3.9 GHz cryomodules to be used in the…

Accelerator Physics · Physics 2017-12-05 Michael White , Benjamin Hansen , Arkadiy Klebaner

In order to develop an RF cavity that is applicable for a muon beam cooling channel, a new facility, called Mucool Test Area (MTA) has been built at Fermilab. MTA is a unique facility whose purpose is to test RF cavities in various…

Accelerator Physics · Physics 2019-08-15 Katsuya Yonehara

A new measurement of the anomalous magnetic moment of the muon, $a_{\mu} \equiv (g-2)/2$, will be performed at the Fermi National Accelerator Laboratory with data taking beginning in 2017. The most recent measurement, performed at…

High Energy Physics - Experiment · Physics 2016-11-16 W. Gohn

The E989 Muon $g-2$ experiment at Fermilab aims to measure the anomalous magnetic moment, $a^{}_\mu$, of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession…

Instrumentation and Detectors · Physics 2021-02-11 S. Corrodi , P. De Lurgio , D. Flay , J. Grange , R. Hong , D. Kawall , M. Oberling , S. Ramachandran , P. Winter

The need for larger mK cooling platforms is being driven by the desire to host ever growing numbers of cryogenic qubits in quantum computing platforms. As part of the Superconducting Quantum Materials and Systems Center at Fermilab funded…

Instrumentation and Detectors · Physics 2022-07-13 Matthew Hollister , Ram Dhuley , Grzegorz Tatkowski

The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the…

Instrumentation and Detectors · Physics 2018-05-15 J. Grange , V. Guarino , P. Winter , K. Wood , H. Zhao , R. M. Carey , D. Gastler , E. Hazen , N. Kinnaird , J. P. Miller , J. Mott , B. L. Roberts , J. Benante , J. Crnkovic , W. M. Morse , H. Sayed , V. Tishchenko , V. P. Druzhinin , B. I. Khazin , I. A. Koop , I. Logashenko , Y. M. Shatunov , E. Solodov , M. Korostelev , D. Newton , A. Wolski , A. Chapelain , R. Bjorkquist , N. Eggert , A. Frankenthal , L. Gibbons , S. Kim , A. Mikhailichenko , Y. Orlov , D. Rubin , D. Sweigart , D. Allspach , G. Annala , E. Barzi , K. Bourland , G. Brown , B. C. K. Casey , S. Chappa , M. E. Convery , B. Drendel , H. Friedsam , T. Gadfort , K. Hardin , S. Hawke , S. Hayes , W. Jaskierny , C. Johnstone , J. Johnstone , V. Kashikhin , C. Kendziora , B. Kiburg , A. Klebaner , I. Kourbanis , J. Kyle , N. Larson , A. Leveling , A. L. Lyon , D. Markley , D. McArthur , K. W. Merritt , N. Mokhov , J. P. Morgan , H. Nguyen , J-F. Ostiguy , A. Para , C. C. Polly M. Popovic , E. Ramberg , M. Rominsky , D. Schoo , R. Schultz , D. Still , A. K. Soha , S. Strigonov , G. Tassotto , D. Turrioni , E. Villegas , E. Voirin , G. Velev , L. Welty-Rieger , D. Wolff , C. Worel , J-Y. Wu , R. Zifko , K. Jungmann , C. J. G. Onderwater , P. T. Debevec , S. Ganguly , M. Kasten , S. Leo , K. Pitts , C. Schlesier , M. Gaisser , S. Haciomeroglu , Y-I. Kim , S. Lee , M-J Lee , Y. K. Semertzidis , K. Giovanetti , V. A. Baranov , V. N. Duginov , N. V. Khomutov , V. A. Krylov , N. A. Kuchinskiy , V. P. Volnykh , C. Crawford , R. Fatemi , W. P. Gohn , T. P. Gorringe , W. Korsch , B. Plaster , A. Anastasi , D. Babusci , S. Dabagov , C. Ferrari , A. Fioretti , C. Gabbanini , D. Hampai , A. Palladino , G. Venanzoni , T. Bowcock , J. Carroll , B. King , S. Maxfield , K. McCormick , J. Price , D. Sim , A. Smith , T. Teubner , W. Turner , M. Whitley , M. Wormald , R. Chislett , S. Kilani , M. Lancaster , E. Motuk , T. Stuttard , M. Warren , D. Flay , D. Kawall , Z. Meadows , T. Chupp , R. Raymond , A. Tewlsey-Booth , M. J. Syphers , D. Tarazona , S. Catalonotti , R. Di Stefano , M. Iacovacci , S. Mastroianni , S. Chattopadhyay , M. Eads , M. Fortner , D. Hedin , N. Pohlman , A. de Gouvea , H. Schellman , L. Welty-Rieger , F. Azfar , S. Henry , G. D. Alkhazov , V. L. Golovtsov , P. V. Neustroev , L. N. Uvarov , A. A. Vasilyev , A. A. Vorobyov , M. B. Zhalov , L. Cerrito , F. Gray , G. Di Sciascio , D. Moricciani , C. Fu , X. Ji , L. Li , H. Yang , D. Stöckinger , G. Cantatore , D. Cauz , M. Karuza , G. Pauletta , L. Santi , S. Baeßler , M. Bychkov , E. Frlez , D. Pocanic , L. P. Alonzi , M. Fertl , A. Fienberg , N. Froemming , A. Garcia , D. W. Hertzog J. Kaspar , P. Kammel , R. Osofsky , M. Smith , E. Swanson , T. van Wechel , K. Lynch

The Proton Improvement Plan-II (PIP-II) is a major upgrade to the Fermilab accelerator complex, featuring a new 800-MeV Superconducting Radio-Frequency (SRF) linear accelerator (Linac) powering the accelerator complex to provide the world's…

Accelerator Physics · Physics 2023-08-23 A Martinez , J Creus Prats , W Soyars , R Dhuley , B Hansen , Y Jia , A Chakravarty , M Goyal , T Banaszkiewicz , P Duda , M Stanclik

Precision measurements of fundamental quantities have played a key role in pointing the way forward in developing our understanding of the universe. Though the enormously successful Standard Model (SM) describes the breadth of both…

High Energy Physics - Experiment · Physics 2019-08-14 J. Grange

Low-energy medium-luminosity Muon Collider (MC) is being studied as a possible Higgs Factory (HF). Electrons from muon decays will deposit more than 300 kW in superconducting magnets of the HF collider ring. This imposes significant…

Accelerator Physics · Physics 2018-11-14 N. V. Mokhov , V. V. Kashikhin , S. I. Striganov , I. S. Tropin , A. V. Zlobin

Ionizing radiation has emerged as a potential limiting factor for superconducting quantum processors, inducing quasiparticle bursts and correlated errors that challenge fault-tolerant operation. Atmospheric muons are particularly…

Superconducting circuits are a strong contender for realizing quantum computing systems, and are also successfully used to study quantum optics and hybrid quantum systems. However, their cryogenic operation temperatures and the current lack…

I report on the progress of two new muon anomalous magnetic moment experiments, which are in advanced design and construction phases. The goal of Fermilab E989 is to reduce the experimental uncertainty of $a_\mu$ from Brookhaven E821 by a…

High Energy Physics - Experiment · Physics 2016-06-22 David W. Hertzog

CERN is now setting up String 2, a full-size prototype of a regular cell of the LHC arc. It is composed of two quadrupole, six dipole magnets, and a separate cryogenic distribution line (QRL) for the supply and recovery of the cryogen. An…

Instrumentation and Detectors · Physics 2007-05-23 A. Suraci , T. Bager , Ch. Balle , E. Blanco , J. Casas , P. Gomes , S. Pelletier , L. Serio , N. Vauthier