English
Related papers

Related papers: Hyperspectral optical diffraction tomography

200 papers

Simultaneous imaging of fluorescence-labeled and label-free phase objects in the same sample provides distinct and complementary information. Most multimodal fluorescence-phase imaging operates in transmission mode, capturing fluorescence…

Optics · Physics 2024-08-20 Renzhi He , Yucheng Li , Junjie Chen , Yi Xue

We present a tomographic imaging technique, termed Deep Prior Diffraction Tomography (DP-DT), to reconstruct the 3D refractive index (RI) of thick biological samples at high resolution from a sequence of low-resolution images collected…

Image and Video Processing · Electrical Eng. & Systems 2021-11-18 Kevin C. Zhou , Roarke Horstmeyer

Hyperspectral microscopy is an imaging technique that provides spectroscopic information with high spatial resolution. When applied in the relevant wavelength region, such as in the infrared (IR), it can reveal a rich spectral fingerprint…

Optical diffraction tomography (ODT) is a three-dimensional (3D) quantitative phase imaging technique, which enables the reconstruction of the 3D refractive index (RI) distribution of a transparent sample. Due to its fast, non-invasive, and…

Optics · Physics 2018-11-14 Chansuk Park , Seungwoo Shin , Yongkeun Park

Optical diffraction tomography (ODT) enables non-invasive information-rich 3D refractive index (RI) reconstruction of unimpaired transparent biological and technical samples, crucial in biomedical research, optical metrology, materials…

In this paper we present a method to robustly evaluate the quantitative accuracy of various tomographic phase microscopy (TPM) methods with a multiple scattering 3D-printed microphantom with known geometry and refractive index distribution.…

White light spectral interferometry is applied to measure the refractive index in absorbing liquids in the spectral range from 400 to 1000 nm. We analyze the influence of absorption on the visibility of interferometric fringes and,…

This article presents a method to perform diffraction tomography in a standard microscope that includes an LED array for illumination. After acquiring a sequence of intensity-only images of a thick sample, a ptychography-based…

Optics · Physics 2015-10-30 Roarke Horstmeyer , Changhuei Yang

We developed a microscopy technique that can measure the local refractive index without sampling the optical phase delay of the electromagnetic radiation. To do this, we designed and experimentally demonstrated a setup with two co-localized…

Optics · Physics 2019-03-27 Antonio Fiore , Carlo Bevilacqua , Giuliano Scarcelli

It is shown that reflective laser refractometery at Brewster angle can be usefull for precision measurements of refractive indexes (RI) in the transparency band of various films of nanoscale thickness. The RI measurements of nanoscale…

Optics · Physics 2015-04-17 E. A. Tikhonov , A. K. Lyamets , Yu. V. Malyukin

Quantitative phase imaging (QPI) is a label-free technique that provides optical path length information for transparent specimens, finding utility in biology, materials science, and engineering. Here, we present quantitative phase imaging…

The refractive index of novel organosilica (nano/micro)material is determined using two methods. The first method is based on analysis of optical extinction efficiency of organosilica beads versus wavelength, which is obtained by a standard…

Methods of three-dimensional deconvolution (3DD) or volumetric deconvolution of optical complex-valued wavefronts diffracted by 3D samples with the 3D point spread function are presented. Particularly, the quantitative correctness of the…

Optics · Physics 2022-01-11 Tatiana Latychevskaia

The non-interference three-dimensional refractive index(RI) tomography has attracted extensive attention in the life science field for its simple system implementation and robust imaging performance. However, the complexity inherent in the…

Optics · Physics 2023-06-13 Delong Yang , Shaohui Zhang , Yao Hu , Qun Hao

Optical diffraction tomography (ODT) produces three dimensional distribution of refractive index (RI) by measuring scattering fields at various angles. Although the distribution of RI index is highly informative, due to the missing cone…

Image and Video Processing · Electrical Eng. & Systems 2021-07-20 Hyungjin Chung , Jaeyoung Huh , Geon Kim , Yong Keun Park , Jong Chul Ye

Optical diffraction tomography (ODT) is a tomographic technique that can be used to measure the three-dimensional (3D) refractive index distribution within living cells without the requirement of any marker. In principle, ODT can be…

Quantitative Methods · Quantitative Biology 2018-01-03 Paul Müller , Mirjam Schürmann , Chii J. Chan , Jochen Guck

Holographic Tomography (HT) or Optical Diffraction Tomography (ODT) provides slice-by-slice information about the refractive index (RI) of three-dimensional (3D) samples and is emerging as an important label-free imaging modality for Life…

Image and Video Processing · Electrical Eng. & Systems 2025-04-22 N Goyal , K Khare

Coherent X-ray diffraction microscopy is a method of imaging non-periodic isolated objects at resolutions only limited, in principle, by the largest scattering angles recorded. We demonstrate X-ray diffraction imaging with high resolution…

Conventional three-dimensional (3D) imaging methods require multiple measurements of the sample in different orientation or scanning. When the sample is probed with coherent waves, a single two-dimensional (2D) intensity measurement is…

Image and Video Processing · Electrical Eng. & Systems 2022-01-25 Tatiana Latychevskaia

Optical frequency combs have revolutionised time and frequency metrology [1, 2]. The advent of microresonator-based frequency combs ('microcombs' [3-5]) is set to lead to the miniaturisation of devices that are ideally suited to a wide…