English
Related papers

Related papers: Radiation Hard & High Light Yield Scintillator Sea…

200 papers

Modern high-energy physics experiments are in ever increasing need for radiation hard scintillators and detectors. In this regard, we have studied various radiation-hard scintillating materials such as Polyethylene Naphthalate (PEN),…

Instrumentation and Detectors · Physics 2016-11-17 Emrah Tiras , James Wetzel , Burak Bilki , David Winn , Yasar Onel

Radiation damage in the plastic scintillator and/or readout WLS fibers in the HE endcap calorimeter 1.4<y<4 in the CMS experiment at LHC and SLHC will require remediation after 2018. We describe one alternative using the existing brass…

Instrumentation and Detectors · Physics 2013-08-28 Burak Bilki , Yasar Onel , David R. Winn , Taylan Yetkin

Analysis of the CMS data and the simulation prediction based on these results indicate that the performance of the current scintillators in the CMS Hadron Endcap Calorimeter (HE) tiles will degrade dramatically in the High Luminosity LHC…

Instrumentation and Detectors · Physics 2013-08-30 Yasar Onel , David Winn

A study has been performed to understand the effects of radiation damage on various plastic scintillator tiles considered for a possible upgrade of the hadron calorimeter of the CMS detector. Measurements were made with unirradiated tiles…

Instrumentation and Detectors · Physics 2024-09-30 The CMS HCAL Collaboration

An irradiation campaign was conducted to provide guidance in the selection of materials and components for the radiation hardening of LED lights for use in CERN accelerator tunnels. This work describes the effects of gamma-rays on…

Accelerator Physics · Physics 2020-10-14 Alessandro Floriduz , James D. Devine

Measurements are presented of the reduction of signal output due to radiation damage for plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in…

Instrumentation and Detectors · Physics 2020-06-15 CMS Collaboration

There are presented the results of radiation hardness study of calorimeter active elements. One element is based on organic scintillator with wave length shifting fiber light collection. The other one is an element based on a Thick Gas…

Instrumentation and Detectors · Physics 2011-08-29 Victor Kryshkin , Victor Skvortsov

In Particle and Nuclear Physics research and related applications, organic scintillators provide a cost-effective technology for the detection of ionising radiation. The next generation of experiments in this field is driving fundamental…

Instrumentation and Detectors · Physics 2024-07-31 P. Conde Muíño , J. A. Covas , A. Gomes , L. Gurriana , R. Machado , T. Martins , P. Mendes , R. Pedro , B. Pereira , A. J. Pontes , H. Wilkens

The CMS hadron Calorimeter is made of alternating layers of scintillating tiles and metals, such as brass or iron. The original photo detectors were hybrid units with a single accelerating gap called Hybrid Photo Diodes (HPD). Scintillating…

Instrumentation and Detectors · Physics 2018-06-27 R A Shukla , V G Achanta , P D Barbaro , S R Dugad , A Heering , S K Gupta , I Mirza , S S Prabhu , P Rumerio

We have developed particle detectors based on fused silica (quartz) Cherenkov radiators read out with micro-channel plate photomultipliers (MCP-PMTs) or silicon photomultipliers (SiPMs) for high precision timing (Sigma(t) about 10-15 ps).…

Instrumentation and Detectors · Physics 2015-06-05 M. G. Albrow , Heejong Kim , S. Los , E. Ramberg , A. Ronzhin , V. Samoylenko , H. Wenzel , A. Zatserklyaniy

The High Luminosity Large Hadron Collider (HL-LHC) at CERN is expected to collide protons at a center-of-mass energy of 14 TeV and to reach the unprecedented peak instantaneous luminosity of $7.5 \times 10^{34} \text{cm}^{-2} \text{s}^{-1}$…

Instrumentation and Detectors · Physics 2023-01-26 Sascha Liechti

During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb$^{-1}$. The expected experimental conditions in that period in terms of background rates,…

Instrumentation and Detectors · Physics 2022-01-19 A. Samalan , M. Tytgat , G. A. Alves , F. Marujo , F. Torres Da Silva De Araujo , E. M. DaCosta , D. De Jesus Damiao , H. Nogima , A. Santoro , S. Fonseca De Souza , A. Aleksandrov , R. Hadjiiska , P. Iaydjiev , M. Rodozov , M. Shopova , G. Soultanov , M. Bonchev , A. Dimitrov , L. Litov , B. Pavlov , P. Petkov , A. Petrov , S. J. Qian , C. Bernal , A. Cabrera , J. Fraga , A. Sarkar , S. Elsayed , Y. Assran , M. El Sawy , M. A. Mahmoud , Y. Mohammed , C. Combaret , M. Gouzevitch , G. Grenier , I. Laktineh , L. Mirabito , K. Shchablo , I. Bagaturia , D. Lomidze , I. Lomidze , V. Bhatnagar , R. Gupta , P. Kumari , J. Singh , V. Amoozegar , B. Boghrati , M. Ebraimi , R. Ghasemi , M. Mohammadi Najafabadi , E. Zareian , M. Abbrescia , R. Aly , W. Elmetenawee , N. DeFilippis , A. Gelmi , G. Iaselli , S. Leszki , F. Loddo , I. Margjeka , G. Pugliese , D. Ramos , M. Caponero , L. Benussi , S. Bianco , S. Colafranceschi , A. Russo , L. Passamonti , D. Piccolo , D. Pierluigi , G. Saviano , S. Buontempo , A. Di Crescenzo , F. Fienga , G. DeLellis , L. Lista , S. Meola , P. Paolucci , A. Braghieri , P. Salvini , P. Montagna , C. Riccardi , P. Vitulo , B. Francois , T. J. Kim , J. Park , S. Y. Choi , B. Hong , K. S. Lee , J. Goh , H. Lee , J. Eysermans , C. Uribe Estrada , I. Pedraza , H. Castilla-Valdez , A. Sanchez-Hernandez , C. A. Mondragon Herrera , D. A. Perez Navarro , G. A. AyalaSanchez , S. Carrillo , E. Vazquez , N. Zaganidis , A. Radi , A. Ahmad , I. Asghar , H. Hoorani , S. Muhammad , M. A. Shah , B. Mandelli , R. Guida , I. Crotty

Pixel detectors are used in the innermost part of the multi purpose experiments at LHC and are therefore exposed to the highest fluences of ionising radiation, which in this part of the detectors consists mainly of charged pions. The…

Instrumentation and Detectors · Physics 2010-11-30 T. Rohe , A. Bean , W. Erdmann , H. -C. Kaestli , S. Khalatyan , B. Meier , V. Radicci , J. Sibille

This article presents the timing performance of materials with fast light emission, tested as Minimum Ionizing Particle detectors using 150 GeV hadron beams in Monte Carlo simulations and at the CERN SPS North Area. Pixels of cross-section…

The Caltech HEP Crystal Lab has been actively investigating novel inorganic scintillators along the following three directions. Fast and radiation hard inorganic scintillators to face the challenge of severe radiation environment expected…

Instrumentation and Detectors · Physics 2024-08-21 Liyuan Zhang , Ren-Yuan Zhu

Lead halide perovskite nanocrystals (LHP-NCs) embedded in a plastic matrix are highly promising for a variety of photonic technologies and are quickly gaining attention as ultrafast, radiation-resistant nanoscintillators for radiation…

In the High Luminosity Large Hadron Collider (HL-LHC) program, during the next years, the instantaneous luminosity will increase up to 5 $\times$ 10$^{34}$ cm$^{-2}$ s$^{-1}$ which means a factor five higher than the nominal LHC. In that…

Instrumentation and Detectors · Physics 2021-11-30 R. Aly

The anticipated performance of calorimeter crystals in the environment expected after the planned High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) at CERN has to be well understood, before informed decisions can be made on the…

Instrumentation and Detectors · Physics 2015-06-04 G. Dissertori , D. Luckey , F. Nessi-Tedaldi , F. Pauss , R. Wallny , R. Spikings , R. Van der Lelij , G. Arnau Izquierdo

The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of the radiation background measurements performed with the 2011…

Instrumentation and Detectors · Physics 2019-08-13 Silvia Costantini
‹ Prev 1 2 3 10 Next ›