Related papers: Compact Low-Voltage, High-Power, Multi-beam Klystr…
A 52MHz Radio Frequency Quadrupole (RFQ) linear accelerator (linac) is designed to serve as an initial structure for the SSC-linac system (injector into Separated Sector Cyclotron). The designed injection and output energy are 3.5 keV/u and…
The positron source is an essential component of the International Linear Collider (ILC) and is an area that poses some design challenges. One consideration is the material for the target, where the 1014 positrons per second for the ILC are…
Thick, fully depleted p-channel charge-coupled devices (CCDs) have been developed at the Lawrence Berkeley National Laboratory (LBNL). These CCDs have several advantages over conventional thin, n-channel CCDs, including enhanced quantum…
This paper presents the experimental results of $17~MeV$ proton irradiation on a $60~GHz$ low power, half-duplex transceiver (TRX) chip implemented in $65~nm$ CMOS technology. It supports short range point-to-point data rate up to $6~Gbps$…
The proposed cyclotron gas-stopping scheme for the efficient thermalization of intense rare isotope beams is examined. Simulations expand on previous studies and expose many complications of such an apparatus arising from physical effects…
Three prototype 6-cell superconducting cavities for acceleration in the velocity range of 0.40 to 0.53 times the speed of light have been fabricated. The quality factor (Q) of the first prototype cavity was above 1E10 for accelerating…
KEK-ATF is studying low emittance, multi-bunch electron beam for the future linear collider. The energy instability of the 1.5 GeV linac has been a problem making the beam injection to the damping ring unstable. Because the unstable beam…
We report on the optical commissioning of the high power laser beam circulator (LBC) for the high brightness Compton {\gamma}-ray source Extreme Light Infrastructure for Nuclear Physics. Tests aiming at demonstrating the optical…
The high energy beam transport (HEBT) line for the ISAC radioactive beam facility at TRIUMF requires an 11.8 MHz buncher. The main requirements of the buncher are to operate in cw mode with a velocity acceptance of 2.2% and an effective…
This paper describes the experience with the calibration, reconstruction and evaluation of the timing capabilities of the CMS HGCAL prototype in the beam tests in 2018. The calibration procedure includes multiple steps and corrections…
A new ion source will be prepared for the CYCLONE30 commercial cyclotron with a much advanced performance compared with the previous one. The newly designed ion source has a very large transparency without deteriorating the beam optics,…
The PLS-II has a 100 MeV pre-injector for the 3 GeV Linac. A thermionic gun produces electron charge of 200 pC with a bunch duration of 500 ps by a 250 ps triggering pulser. At the pre-injector, one of the most important beam parameters to…
First beam commissioning of SuperKEKB (Phase-1), which is an asymmetry double ring collider of 7-GeV electron and 4-GeV positron beams, which had started from February, has been successfully accomplished at the end of June 2016, and the…
The MTA beam line has been specifically designed to facilitate measurements of the Fermilab Linac beam emittance and properties utilizing a long, 10m, element-free straight. Linac beam is extracted downstream of the 400-MeV electrostatic…
A possible solution to realize a conventional positron source driven by a several-GeV electron beam for the International Linear Collider is proposed. A 300 Hz electron linac is employed to create positrons with stretching pulse length in…
The project of a10MeV PET cyclotron accelerator for medical diagnosis and treatment was started at Amirkabir University of Technology in 2012. The low-level RF system of cyclotron accelerator is designed to stabilize acceleration voltage…
The technological prototype of the CALICE highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) was tested in a beam at DESY in 2017. The setup comprised seven layers of silicon sensors. Each layer comprised four sensors,…
Multiple Electrostatic Quadrupole Array Linear Accelerators (MEQALACs) provide an opportunity to realize compact radio-frequency (RF) accelerator structures that can deliver very high beam currents. MEQALACs have been previously realized…
A concept for a two-stage injection-locked CW magnetron intended to drive Superconducting Cavities (SC) for intensity-frontier accelerators has been proposed. The concept considers two magnetrons in which the output power differs by 15-20…
A prototype for a sampling calorimeter made out of cerium fluoride crystals interleaved with tungsten plates, and read out by wavelength-shifting fibres, has been exposed to beams of electrons with energies between 20 and 150 GeV, produced…