Related papers: Clock and inter-combination line frequency separat…
We have carried absolute frequency measurements of the $(6s^{2})\,^{1}S_{0}$ $-$ $(6s6p)\,^{3}P_{1}$ transition in $^{171}$Yb (the intercombination line), where the spin-1/2 isotope yields two hyperfine lines. The measurements rely on…
We report the direct excitation of the highly forbidden (6s^2) 1S0 - (6s6p) 3P0 optical transition in two odd isotopes of ytterbium. As the excitation laser frequency is scanned, absorption is detected by monitoring the depletion from an…
We have measured the frequency of the $6s^2S_{1/2} - 5d^2D_{3/2}$ electric-quadrupole transition of $^{171}$Yb$^+$ with a relative uncertainty of $1\times 10^{-14}$, $\nu_{Yb}$ = 688 358 979 309 312 Hz $\pm$ 6 Hz. A femtosecond frequency…
We report on the observation of the $4f^{14}6s^{2}~^1S_0- 4f^{13}5d6s^{2}(J=2)$ transition at 431 nm in $^{171}$Yb by depleting atoms in a magneto-optical trap formed by the $6s^{2}~^1S_0-6s6p~^3P_1$ intercombination transition. The…
We describe experiments with an optical frequency standard based on a laser cooled $^{171}$Yb$^+$ ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the $^2S_{1/2}(F=0)$ ground state to the $^2D_{3/2}(F=2)$…
We measured the absolute frequency of the $^1S_0$ - $^3P_0$ transition of $^{171}$Yb atoms confined in a one-dimensional optical lattice relative to the SI second. The determined frequency was 518 295 836 590 863.38(57) Hz. The uncertainty…
The frequency ratio of the 1S0(F=1/2)-3P0(F=1/2) clock transition in 171Yb and the 1S0(F=9/2)-3P0(F=9/2) clock transition in 87Sr is measured by an optical-optical direct frequency link between two optical lattice clocks. We determined the…
We determine the frequency of the Yb I $^1S_0 - ^1P_1$ transition at 399 nm using an optical frequency comb. Although this transition was measured previously using an optical transfer cavity [D. Das et al., Phys. Rev. A 72, 032506 (2005)],…
We report an observation of the weak $6^{1}$S$_{0}$-$6^3$P$_0$ transition in $^{171,173}$Yb as an important step to establish Yb as a primary candidate for future optical frequency standards, and to open up a new approach for qubits using…
We report the first experimental determination of the hyperfine quenching rate of the $6s^2\ ^1\!S_0\ (F=1/2) - 6s6p\ ^3\!P_0\ (F=1/2)$ transition in $^{171}$Yb with nuclear spin $I=1/2$. This rate determines the natural linewidth and the…
Singly-ionized ytterbium, with ultra-narrow optical clock transitions at 467 nm and 436 nm, is a convenient system for the realization of optical atomic clocks and tests of present-day variation of fundamental constants. We present the…
The highly forbidden $^2$S$_{1/2} \rightarrow ^2$F$_{7/2}$ electric octupole transition in $^{171}$Yb$^+$ is a potential candidate for a redefinition of the SI second. We present a measurement of the absolute frequency of this optical…
We used Precise Point Positioning, a well-established GPS carrier-phase frequency transfer method to perform a direct remote comparison of two optical frequency standards based on single laser-cooled $^{171}$Yb$^+$ ions operated at NPL, UK…
We present measurements of the hyperfine splitting in the Yb-173 $6s6p~^1P_1^{\rm o} (F^{\prime}=3/2,7/2)$ states that disagree significantly with those measured previously by Das and Natarajan [Phys. Rev. A 76, 062505 (2007)]. We point out…
We report improved absolute frequency measurement of the $^{1}$S$_{0}-^{3}$P$_{0}$ transition of $^{171}$Yb at National Metrology Institute of Japan (NMIJ) by comparing the $^{171}$Yb optical lattice clock NMIJ-Yb1 with 13 Cs primary…
We present the new absolute frequency measurement of ytterbium (171Yb) obtained at INRiM with the optical lattice clock IT-Yb1 against the cryogenic caesium (133Cs) fountain IT-CsF2, evaluated through a measurement campaign that lasted 14…
We report an uncertainty evaluation of an optical lattice clock based on the $^1S_0\leftrightarrow^3P_0$ transition in the bosonic isotope $^{174}$Yb by use of magnetically induced spectroscopy. The absolute frequency of the…
A full evaluation of the uncertainty budget for the ytterbium ion optical clock at the National Physical Laboratory (NPL) was performed on the electric octupole (E3) $^2\mathrm{S}_{1/2}\,\rightarrow\, ^2\mathrm{F}_{7/2}$ transition. The…
We report on a frequency measurement of the $(3s^2)^1S_0\to(3s3p)^3P_1$ clock transition of $^{24}$Mg on a thermal atomic beam. The intercombination transition has been referenced to a portable primary Cs frequency standard with the help of…
Recently, p-wave cold collisions were shown to dominate the density-dependent shift of the clock transition frequency in a 171Yb optical lattice clock. Here we demonstrate that by operating such a system at the proper excitation fraction,…