Related papers: Generic guide concepts for the European Spallation…
The Scanning electron microscope (SEM) and Electron-Dispersive Spectroscope (EDS) are two highly effective instruments in the field of nanoscience and nanotechnology. The quality of these instruments is determined by various factors, with…
The SPIDER experiment, part of the Neutral Beam Test Facility (NBTF) at Consorzio RFX (Padua, Italy), is the prototype of the negative ion source for the ITER neutral beam injectors; the source is coupled to a 100 kV three-grid acceleration…
We present a new experimental method for measuring the process of Coherent Elastic Neutrino Nucleus Scattering (CENNS). This method uses a detector situated transverse to a high energy neutrino beam production target. This detector would be…
The physics basis for an electron-beam based Compton scattering (ECOS) x-ray source is investigated for single-shot experiments at major high energy density facilities such as the Omega Laser Facility, National Ignition Facility, and Z…
The development of the flat moderator concept at ESS recently opened up the possibility that a single flat moderator above the target could serve all the scattering instruments, that rely on high brightness. This would allow for the…
A beam-energy-spread monitor is under development in order to control and stabilize the energy spread of high-current single-bunch electron beams for producing a sufficient number of positrons. The author has proposed a new monitor using…
The neutron time-of-flight (n_TOF) facility at the European Laboratory for Particle Physics (CERN) is a pulsed white-spectrum neutron spallation source producing neutrons for two experimental areas: the Experimental Area 1 (EAR1), located…
Back-streaming neutrons from the spallation target of the China Spallation Neutron Source (CSNS) that emit through the incoming proton channel were exploited to build a white neutron beam facility (the so-called Back-n white neutron…
Exceptional points (EPs) have been suggested for ultra-sensitive sensing because the eigenfrequency splitting grows as the nth-root of a perturbation, suggesting divergent responsivity. In ideal linear devices, however, this responsivity…
The GanESS experiment will exploit the high-pressure noble gas time projection chamber technology to detect coherent elastic neutrino-nucleus scattering (CE$\nu$NS) at the European Spallation Source (ESS). The detector, able to operate at…
METIS, the Mid-infrared ELT Imager and Spectrograph (formerly called MIDIR), is a proposed instrument for the European Extremely Large Telescope (E-ELT), currently undergoing a phase-A study. The study is carried out within the framework of…
Electron-positron pairs, produced in intense laser-solid interactions, are diagnosed using magnetic spectrometers with image plates, such as the National Ignition Facility (NIF) Electron Positron Proton Spectrometers (EPPS). Although…
A portable monoenergetic 24 keV neutron source based on the $^{124}$Sb-$^9$Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction…
Specifications of the European XFEL cover a range of wavelengths down to 0.1 nm. The baseline design of the European XFEL assumes standard (SASE) FEL mode for production of radiation i.e. only one photon beam at one fixed wavelength from…
Nearly-sterile neutrinos with masses in the MeV range and below would be produced in the beam of the Short-Baseline Neutrino (SBN) program at Fermilab. In this article, we study the potential for SBN to discover these particles through…
The design of a primary electron beam facility at CERN is described. The study has been carried out within the framework of the wider Physics Beyond Colliders study. It re-enables the Super Proton Synchrotron (SPS) as an electron…
The uncertainty in the initial neutrino flux is the main limitation for a precise determination of the absolute neutrino cross section. The ERC funded ENUBET project (2016-2021) is studying a facility based on a narrow band beam to produce…
Text-to-3D generation often suffers from the Janus problem, where objects look correct from the front but collapse into duplicated or distorted geometry from other angles. We attribute this failure to viewpoint bias in 2D diffusion priors,…
Scanning Electron Microscopy (SEM) is indispensable in modern materials science, enabling high-resolution imaging across a wide range of structural, chemical, and functional investigations. However, SEM imaging remains constrained by…
The measurement of the electron energy distribution (EED) of electrons escaping axially from a minimum-B electron cyclotron resonance ion source (ECRIS) is reported. The experimental data were recorded with a room-temperature 14 GHz ECRIS…