English
Related papers

Related papers: Using pulse shape analysis to improve the position…

200 papers

A two-dimensional position-sensitive microchannel plate detector, with a {\O}100 mm sensitive area and equipped with four integrated amplifiers, is realized with a new anode scheme. The anode is constructed by two independent…

Instrumentation and Detectors · Physics 2018-08-01 Yuezhao Zhang , Deyang Yu , Junliang Liu , Liping Yang , Wei Wang , Xiaoxiao Li , Xiaona Zhu , Xiaoxun Song , Xinfei Hui , Wei Xi , Xin Li , Huiping Liu , Xiaohong Cai

We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an {\em in situ} calibration mask, an accuracy of 8~$\mu$m and a resolution of…

A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E$\times$B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in…

Instrumentation and Detectors · Physics 2017-09-20 B. B. Wiggins , Varinderjit Singh , J. Vadas , J. Huston , T. K. Steinbach , S. Hudan , R. T. deSouza

Micro-channel-plate-based photo-detectors are unique in being capable of covering areas of many square-meters while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, time…

Instrumentation and Detectors · Physics 2020-10-28 Jinseo Park , Fangjian Wu , Evan Angelico , Henry J. Frisch , Eric Spieglan

Micro-pattern gas detectors, such as the Gas Electron Multiplier (GEM) and the Micromegas need narrow high density anode readout elements to achieve good spatial resolution. A high-density anode readout would require an unmanageable number…

Instrumentation and Detectors · Physics 2011-07-19 M. S. Dixit , J. Dubeau , J. -P. Martin , K. Sachs

This paper presents a first study of the performance of a novel 2D position-sensitive microstrip detector, where the resistive charge division method was implemented by replacing the metallic electrodes with resistive electrodes made of…

Instrumentation and Detectors · Physics 2015-05-28 D. Bassignana , M. Fernandez , R. Jaramillo , M. Lozano , F. J. Munoz , G. Pellegrini , D. Quirion , I. Vila

With their fast response time and a spatial resolution in the range of a few microns, microchannel plates (MCPs) are a prominent choice for the development of detectors with highest resolution standards. Amorphous silicon-based microchannel…

Instrumentation and Detectors · Physics 2019-02-28 Janina Löffler , Christophe Ballif , Nicolas Wyrsch

Performance of a simple method of particle identification via pulse rise time discrimination is demonstrated for slow pulses from charge-sensitive preamplifiers with rise times ranging from 10 ns to 500 ns. The method is based on a…

Nuclear Experiment · Physics 2008-11-26 Jan Tõke , Michael J. Quinlan , Wojtek Gawlikowicz , W. Udo Schröder

The concept and subsequent experimental verification of the proportionality between pulse amplitude and detector transit time for microchannel plate detectors is presented. This discovery has led to considerable improvement in the overall…

Quantum Physics · Physics 2009-11-13 Victor D. Irby

Resistive Plate Chamber (RPC) is a gaseous detector, known for its good spatial resolution and excellent time resolution. Due to its fast response and excellent time resolution, it is used for both triggering and timing purpose. But the…

Instrumentation and Detectors · Physics 2022-10-26 Jaydeep Datta , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar

Nowadays, commonly used Resistive Plate Chambers (RPCs) have counting rate capabilities of ~10E4Hz/cm2 and position resolutions of ~1cm. We have developed small prototypes of RPCs (5x5 and 10x10cm2) having rate capabilities of up to…

Instrumentation and Detectors · Physics 2015-06-26 C. Iacobaeus , P. Fonte , T. Francke , J. Ostling , V. Peskov , J. Rantanen , I. Rodionov

We present a concept to improve the spatial resolution of silicon pixel-detectors via the implementation of a sub-pixel cross-coupling, which introduces directional charge sharing between pixels. The charge-collection electrode is segmented…

Instrumentation and Detectors · Physics 2020-07-24 Sinuo Zhang , David-Leon Pohl , Tomasz Hemperek , Jochen Dingfelder

We report on a recently developed novel type of large area (62 mm x 62 mm) position sensitive silicon detector with four-corner readout. It consists of a square-shaped ion-implanted resistive anode framed by additional low-resistivity…

Nuclear Experiment · Physics 2008-11-26 A. Banu , Y. Li , M. McCleskey , M. Bullough , S. Walsh , C. A. Gagliardi , L. Trache , R. E. Tribble , C. Wilburn

A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival times of ions at the reaction target. The current…

A new particle detector with sub-nanosecond time resolution capable of working in high-rate environment (rate capability of the order of $MHz/ cm^2$) is under developmnet. Semiconductive electrodes with resistivity $\rho$ up to $10^8…

Instrumentation and Detectors · Physics 2020-01-29 A. Rocchi , R. Cardarelli , G. Aielli , E. Alunno Camelia , S. Bruno , A. Caltabiano , P. Camarri , A. Di Ciaccio , B. Liberti , L. Massa , L. Pizzimento

We present a microchannel plate (MCP) detector for compact time-of-flight mass spectrometers (TOF-MS) that jointly optimizes the anode geometry and high-voltage AC-decoupling network for electrically floating operation. Undershoot-driven…

Instrumentation and Detectors · Physics 2026-05-29 Robin F. Bonny , Lorenzo Obersnel , Martin Rubin , André Galli , Peter Wurz , Rico G. Fausch

A prototype of Multi-strip Multi-gap Resistive Plate chamber (MMRPC) with active area 40 cm $\times$ 20 cm has been developed at SINP, Kolkata. Detailed response of the developed detector was studied with the pulsed electron beam from ELBE…

The conventional readout method of the RPC detector uses two sets of orthogonal readout strips placed at the both sides of the gas gap to collect signals of opposite polarities to obtain space points. A new readout method utilizing the…

Instrumentation and Detectors · Physics 2022-11-22 Y. X. Ding , X. Y. Xie , J. X. Li , K. L. Han , Y. J. Sun

A study of the localization properties of a single-element Resistive Plate WELL (RPWELL) detector is presented. The detector comprises of a single-sided THick Gaseous Electron Multiplier (THGEM) coupled to a segmented readout anode through…

Instrumentation and Detectors · Physics 2017-11-22 Luca Moleri , Purba Bhattacharya , Artur E. C. Coimbra , Amos Breskin , Shikma Bressler

The M\"ONCH hybrid pixel detector, with a 25 \textmu m pixel pitch and fast charge-integrating readout, has demonstrated subpixel resolution capabilities for X-ray imaging and deep learning-based electron localization in electron…

‹ Prev 1 2 3 10 Next ›