Related papers: A classical postselected weak amplification scheme…
Nearly thirty years ago the possibility of anomalous weak amplfication (AWA) was revealed by Aharonov, Albert and Vaidman [1]. Recently two papers presents two AWA schemes which are beyond the traditional proposal given by them [14, 15]. At…
Most studies for postselected weak measurement focus on using pure Gaussian state as a pointer, which can only give an amplification limit reaching the level of the ground state fluctuation. When the pointer is initialised in a thermal…
We revisit the scheme of single-photon weak-coupling optomechanics using post-selection, proposed by Pepper, Ghobadi, Jeffrey, Simon and Bouwmeester [Phys. Rev. Lett. 109, 023601 (2012)], by analyzing the exact solution of the dynamical…
We consider the use of cyclic weak measurements to improve the sensitivity of weak-value amplification precision measurement schemes. Previous weak-value experiments have used only a small fraction of events, while discarding the rest…
We show that weak measurement can be used to "amplify" optical nonlinearities at the single- photon level, such that the effect of one properly post-selected photon on a classical beam may be as large as that of many un-post-selected…
Weak-value-amplification permits small effects to be measured as observable changes at the sacrifice of power due to post-selection. The power recycling scheme has been proven to eliminate this inefficiency of the rare post-selection, thus…
Due to the reduced probability of successful post-selection, the weak-value amplification seems to be unavailable for the parameter-estimation. Here, we show theoretically that, some effects due to the weak interactions present only in the…
Weak measurement [1,19] combined with quantum delayed-choice experiment that use quantum beam splitter instead of the beam splitter give rise to a surprising amplification effect, i.e., counterintuitive negative amplification effect. We…
To describe the pre- and post-selected quantum ensembles, a complex quantity called the weak value of an operator is used. The weak value is highly controversial due to the fact that it is not bounded by the possible eigenvalues of the…
We use weakly nonlinear geometric optics to study a model for the DC Kerr effect (the Kerr electro-optic effect), in which a light beam propagating through a material with strong nonlinear optical properties can have its polarization…
An interferometric arrangement is proposed in which the technique of weak value amplification is implemented in order to enlarge the effect of a single photon on the quadratures of a movable mirror of an optical cavity. The photon interacts…
The meaning and its possible applications of post-selected weak amplification in optomechanical system is concisely reviewed.
Weak measurement with a coherent state pointer and in combination with an orthogonal postselection can lead to a surprising amplification effect, and we give a fire-new physical mechanism about the weak measurement in order to understand…
We measure a transverse momentum kick in a Sagnac interferometer using weak-value amplification with two postselections. The first postselection is controlled by a polarization dependent phase mismatch between both paths of a Sagnac…
Weak amplification is a signal enhancement technique which is used to measure tiny changes that otherwise cannot be determined because of technical limitations. It is based on the existence of a special type of interaction which couples a…
The application of postselection to a weak quantum measurement leads to the phenomenon of weak values. Expressed in units of the measurement strength, the displacement of a quantum coherent measuring device is ordinarily bounded by the…
Weak measurements in combination with post-selection can give rise to a striking amplification effect (related to a large "weak value"). We show that this effect can be understood by viewing the initial state of the pointer as the ground…
Most studies for postselected weak measurement in optomechanical system focus on using a single photon as a measured system. However, we find that using weak coherent light instead of a single photon can also amplify the mirror's position…
An experimental proposal is presented in which dark port post-selection together with weak measurements are used to enlarge the radiation pressure effect of a single photon on a mechanical oscillator placed in the middle of a Fabry-Perot…
We improve the precision of the interferometric weak-value-based beam deflection measurement by introducing a power recycling mirror, creating a resonant cavity. This results in \emph{all} the light exiting to the detector with a large…