Related papers: A Novel Method of Encoded Multiplexing Readout for…
Current radiation portal monitors at sea ports and international borders that employ standard radiation detection techniques are not very sensitive to nuclear contraband that is well shielded to absorb emanating radiation. Muon Tomography…
We introduce a frequency-multiplexed readout scheme for superconducting phase qubits. Using a quantum circuit with four phase qubits, we couple each qubit to a separate lumped-element superconducting readout resonator, with the readout…
A sealed high gas pressure detector working in pure argon is assembled. It consists of a 5 cm $\times$ 5 cm PCB THGEM (THick Gaseous Electron Multipliers). The detector structure and experimental setup are described. The performances under…
This paper presents Bit-Interleaved Coded Modulation metrics for joint estimation detection using training or reference signal transmission strategies for short to long block length channels. We show that it is possible to enhance the…
Semi monolithic detector designs with a series of stacked thin monolithic scintillator plates and side readout are an attractive approach for potentially achieving very high performance in a positron emission tomography (PET) scanner. In…
Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future…
Micro-pattern gaseous detectors (MPGDs) are a class of technologies that enable the full three-dimensional spatial reconstruction of ionisation tracks from nuclear and electron recoils in gas. Anticipating near-future 30 m$^3$-scale time…
Thick GEM-like (THGEM) gaseous electron multipliers are made of standard printed-circuit board perforated with sub-millimeter diameter holes, etched at their rims. Effective gas multiplication factors of 100000 and 10000000 and fast pulses…
The fast timing MPGD is a micro-pattern gaseous detector conceived for achieving sub-nanosecond time resolution while maintaining the ability to instrument large areas in high-rate environments; applications of such technology are…
We present a highly frequency multiplexed readout for large-format superconducting detector arrays intended for use in the next generation of balloon-borne and space-based sub-millimeter and far-infrared missions. We will demonstrate this…
We report on the manufacture of a first batch of approximately 2,000 Gas Electron Multipliers (GEMs) using 3M's fully automated roll to roll flexible circuit production line. This process allows low-cost, reproducible fabrication of a high…
We study the potential of the MCP-PMT read-out to detect single photo-electron using transmission lines. Such a solution limits the number of read-out channels, has a uniform time resolution across the PMT surface and provides…
Micro-TPC, a time projection chamber(TPC) with micro pixel chamber($\mu$-PIC) readout was developed for the detection of the three-dimensional fine(sub-m illimeter) tracks of charged particles. We developed a two-dimensional position…
Beam studies of thin single- and double-stage THGEM-based detectors are presented. Several 10 x 10 cm^2 configurations with a total thickness of 5-6 mm (excluding readout electronics), with 1 x 1 cm^2 pads inductively coupled through a…
Recording experiments and decoding algorithms are presented for evaluating the bit-error-rate of state-of-the-art magnetic bitpatterned media. The recording experiments are performed with a static tester and conventional hard-disk-drive…
A novel gaseous two-dimensional imaging detector "Micro Pixel Chamber (micro-PIC)" has been developed. This detector is based on double sided printed circuit board (PCB). We have developed large area (10cm x 10cm) micro-PICs with 65536…
The time resolution of a double-stage Thick-GEM (THGEM) detector was measured with UV-photons and relativistic electrons. The photon detector, with semitransparent- or reflective-photocathode yielded time resolution of about 8-10ns RMS for…
THGEMs (THick Gas Electron Multiplier) of varying thickness, hole diameter and hole pitch have been studied. For a thinner-THGEM of thickness 0.2 mm, with hole diameter 0.2 mm, pitch 0.2 mm and narrow (5-10 {\mu}m) rim, the performance of…
The gas gain and energy resolution of single and double THGEM detectors (5{\times}5cm2 effective area) with mini-rims (rim is less than 10{\mu}m) were studied. The maximum gain can reach 5{\times}103 and 2{\times}105 for single and double…
A simple X-ray imaging system using off-the-shelf electronics and simple reconstruction algorithms aiming a spatial resolution of 1.7 mm ($\sim 3\,\%$ of the detector length) is described in this work. For this, two 100 cm$^2$ Gas Electron…