Related papers: Fused Analytical and Iterative Reconstruction (AIR…
Filtered back projection (FBP) is the most widely used method for image reconstruction in X-ray computed tomography (CT) scanners. The presence of hyper-dense materials in a scene, such as metals, can strongly attenuate X-rays, producing…
Purpose: To introduce a novel deep learning based approach for fast and high-quality dynamic multi-coil MR reconstruction by learning a complementary time-frequency domain network that exploits spatio-temporal correlations simultaneously…
Metal artifact reduction (MAR) is a challenging problem in computed tomography (CT) imaging. A popular class of MAR methods replace sinogram measurements that are corrupted by metal with artificial data. While these ``projection…
Model-Based Iterative Reconstruction (MBIR) is important because direct methods, such as Filtered Back-Projection (FBP) can introduce significant noise and artifacts in sparse-angle tomography, especially for time-evolving samples. Although…
Tri-Structural Isotropic (TRISO) fuel particles are a key component of next generation nuclear fuels. Using X-ray computed tomography (CT) to characterize TRISO particles is challenging because of the strong attenuation of the X-ray beam by…
Image restoration aims to recover high quality images from inputs degraded by various factors, such as adverse weather, blur, or low light. While recent studies have shown remarkable progress across individual or unified restoration tasks,…
X-ray tomography is a reliable tool for determining the inner structure of 3D object with penetrating X-rays. However, traditional reconstruction methods such as FDK require dense angular sampling in the data acquisition phase leading to…
Computed Tomography (CT) is pivotal in industrial quality control and medical diagnostics. Sparse-view CT, offering reduced ionizing radiation, faces challenges due to its under-sampled nature, leading to ill-posed reconstruction problems.…
Statistical image reconstruction (SIR) methods are studied extensively for X-ray computed tomography (CT) due to the potential of acquiring CT scans with reduced X-ray dose while maintaining image quality. However, the longer reconstruction…
Image reconstruction-based anomaly detection models are widely explored in industrial visual inspection. However, existing models usually suffer from the trade-off between normal reconstruction fidelity and abnormal reconstruction…
Iterative image reconstruction (IIR) algorithms in Computed Tomography (CT) are based on algorithms for solving a particular optimization problem. Design of the IIR algorithm, therefore, is aided by knowledge of the solution to the…
Dual-energy computed tomography (DECT) has shown great potential and promising applications in advanced imaging fields for its capabilities of material decomposition. However, image reconstructions and decompositions under sparse views…
X-ray imaging dose from serial cone-beam CT (CBCT) scans raises a clinical concern in most image guided radiation therapy procedures. It is the goal of this paper to develop a fast GPU-based algorithm to reconstruct high quality CBCT images…
In this paper, we systematically evaluate the performance of adaptive adjustment of the relaxation parameters of various iterative algorithms for X-ray CT reconstruction relying on sparsity priors. Sparsity prior has been found to be an…
In functional MRI (fMRI), faster acquisition via undersampling of data can improve the spatial-temporal resolution trade-off and increase statistical robustness through increased degrees-of-freedom. High quality reconstruction of fMRI data…
Real-world images often suffer from spatially diverse degradations such as haze, rain, snow, and low-light, significantly impacting visual quality and downstream vision tasks. Existing all-in-one restoration (AIR) approaches either depend…
Computed tomography (CT) reconstructs volumetric images using X-ray projection data acquired from multiple angles around an object. For low-dose or sparse-view CT scans, the classic image reconstruction algorithms often produce severe noise…
Respiratory motion can cause strong blurring artifacts in the reconstructed image during MR acquisition. These artifacts become more prominent when use in the presence of undersampled data. Recently, compressed sensing (CS) is developed as…
Low Dose Computed Tomography suffers from a high amount of noise and/or undersampling artefacts in the reconstructed image. In the current article, a Deep Learning technique is exploited as a regularization term for the iterative…
Industrial X-ray cone-beam CT (XCT) scanners are widely used for scientific imaging and non-destructive characterization. Industrial CBCT scanners use large detectors containing millions of pixels and the subsequent 3D reconstructions can…