English
Related papers

Related papers: Developing Microwave Photonic Temperature Sensors

200 papers

Optical whispering-gallery microresonators are useful tools in microphotonics, and nonlinear optics at very low threshold powers. Here, we present details about the fabrication of ultra-high-Q whispering-gallery-mode resonators made by…

Optics · Physics 2015-06-16 Pascal Del'Haye , Scott A. Diddams , Scott B. Papp

We present results from cryogenic tests of a Volume-Phase Holographic (VPH) grating at 200 K measured at near-infrared wavelengths. The aims of these tests were to see whether the diffraction efficiency and angular dispersion of a VPH…

We demonstrate the cooling of a microwave mode at 2872 MHz through its interaction with optically spin-polarized NV$^-$ centers in diamond at zero applied magnetic field, removing thermal photons from the mode. By photo-exciting (pumping) a…

Quantum Physics · Physics 2022-03-08 Wern Ng , Hao Wu , Mark Oxborrow

We encapsulated a high-quality (Q) factor optical whispering gallery mode (WGM) microtoroid resonator together with its side coupled fiber taper inside a low refractive index polymer, achieving a final Q higher than 10^7. Packaging provides…

Optics · Physics 2013-07-25 Faraz Monifi , Sahin Kaya Ozdemir , Jacob Friedlein , Lan Yang

In this paper, we report on a multicore fiber-based (MCF) temperature sensor that operates in a wide thermal range and that is robustly packaged to withstand harsh environments. To develop the sensor, the fundamentals concerning the effect…

Whispering gallery mode (WGM) microtoroid resonators are one of the most sensitive biochemical sensors in existence, capable of detecting single molecules. The main barrier for translating these devices out of the laboratory is that light…

Optics · Physics 2024-03-18 Sartanee Suebka , Euan McLeod , Judith Su

Accurate and precise measurements of spectroradiometric temperature are crucial for many high pressure experiments that use diamond anvil cells or shock waves. In experiments with sub-millisecond timescales, specialized detectors such as…

Instrumentation and Detectors · Physics 2023-10-26 Zachary M. Geballe , Francesca Miozzi , Chris F. Anto , Javier Rojas , Jing Yang , Michael J. Walter

We have characterized two state-of-the-art solid-state photomultipliers, one by SensL, the other by Hamamatsu, coupled to scintillators by Saint-Gobain Crystals in the -25 to 50 degrees C temperature range. At room temperature, the energy…

Instrumentation and Detectors · Physics 2011-03-28 Clarisse Tur , Vladimir Solovyev , Jeremy Flamanc

We have achieved low threshold lasing of self-assembled InAs/GaAs quantum dots coupled to the evanescent wave of the high-$Q$ whispering gallery modes of a silica microsphere. In spite of high temperature and $Q$-spoiling of whispering…

Quantum Physics · Physics 2009-11-06 Sébastien Steiner , Jean Hare , Valérie Lefèvre-Seguin , Jean-Michel Gérard

We present an experimental setup and methodology designed to facilitate high-precision thermal measurements required for infrared medical tomography. The approach which is best suited for the study of specialized hardware phantoms comprises…

Medical Physics · Physics 2026-04-08 Anna Frixou , Efstathios Stiliaris , Costas N. Papanicolas

We consider mid-infrared (5 to 25 micrometers), optically cooled detectors based on a microcantilever sensor of the radiation pressure. A significant enhancement of sensitivity is achieved due the combination of low effective temperature…

Mesoscale and Nanoscale Physics · Physics 2009-12-22 Gennady P. Berman , Boris M. Chernobrod , Alan R. Bishop , Umar Mohideen

There is a growing demand for experiments on calorimetric and thermal transport measurements at ultra-low temperatures below 1 mK and high magnetic fields up to 16 T. Particularly, milligram-sized solid samples are of great interest. We…

Instrumentation and Detectors · Physics 2022-10-17 Andrew J. Woods , Alexander. M. Donald , Rasul Gazizulin , Eddy Collin , Lucia Steinke

Thermoreflectance methods by picosecond pulse heating and by nanosecond pulse heating have been developed under the same geometrical configuration as the laser flash method by the National Metrology Institute of JAPAN, AIST. Using these…

Materials Science · Physics 2007-09-13 T. Baba , K. Ishikawa , T. Yagi , N. Taketoshi

Progress in the emerging field of engineered quantum systems requires the development of devices that can act as quantum memories. The realisation of such devices by doping solid state cavities with paramagnetic ions imposes a trade-off…

Materials Science · Physics 2013-11-06 Warrick G. Farr , Daniel L. Creedon , Maxim Goryachev , Karim Benmassai , Michael E. Tobar

Two nominally identical ultra-stable cryogenic microwave oscillators are compared. Each incorporates a dielectric-sapphire resonator cooled to near 6 K in an ultra-low vibration cryostat using a low-vibration pulse-tube cryocooler. The…

Instrumentation and Detectors · Physics 2012-05-15 John G. Hartnett , Nitin R. Nand , Chuan Lu

Laser cooling of mechanical degrees of freedom is one of the most significant achievements in the field of opto-mechanics. Here, we report, for the first time to the best of our knowledge, efficient passive optomechanical cooling of the…

We utilize a high quality calcium fluoride whispering-gallery-mode resonator to stabilize a simple erbium doped fiber ring laser with an emission frequency of 196 THz (wavelenght 1530 nm) to a linewidth below 650 Hz. This corresponds to a…

A removable holder carrying a set of miniature temperature sensors inside our Rayleigh-B\'enard convection cylindrical cell has been developed. The sensors should not disturb the temperature and velocity fields of the buoyancy-driven…

Fluid Dynamics · Physics 2022-04-04 Pavel Hanzelka , Ivan Vlcek , Pavel Urban

Self-heating in surrounding gate transistors can degrade its on-current performance and reduce lifetime. If a transistor heats/cools with time-constants less than the inverse of the operating frequency, a predictable, frequency-independent…

Instrumentation and Detectors · Physics 2016-09-02 SangHoon Shin , Muhammad Masuduzzaman , Muhammad Ashraful Alam

The realization and characterization of a high quality factor resonator composed of two hollow-dielectric cylinders with its pseudo-TM$_{030}$ mode resonating at 10.9 GHz frequency is discussed. The quality factor was measured at the…