English
Related papers

Related papers: High-Rate Capable Floating Strip Micromegas

200 papers

The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of…

Instrumentation and Detectors · Physics 2012-08-27 CMS Collaboration

The present work involves the comparison of various bulk Micromegas detectors having different design parameters. Six detectors with amplification gaps of $64,~128,~192,~220 ~\mu\mathrm{m}$ and mesh hole pitch of $63,~78 ~\mu\mathrm{m}$…

Instrumentation and Detectors · Physics 2016-05-12 Purba Bhattacharya , Sudeb Bhattacharya , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar , Paul Colas , David Attie

The precise reconstruction of Compton-scatter events is paramount for an imaging medium-energy gamma-ray telescope. The proposed AMEGO-X is enabled by a silicon tracker utilizing AstroPix chips - a pixelated silicon HVCMOS sensor novel for…

In this study we report the results of a systematic study of the gain, rate and the position resolution limits of various micropattern gaseous detectors. It was found that at low rates (<1 Hz/mm^2) each detector has it own gain limit, which…

Instrumentation and Detectors · Physics 2007-05-23 V. Peskov , P. Fonte

The bulk Micromegas detector is considered to be a promising candidate for building TPCs for several future experiments including the projected linear collider. The standard bulk with a spacing of 128 micron has already established itself…

Instrumentation and Detectors · Physics 2016-05-11 Purba Bhattacharya , Sudeb Bhattacharya , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar , Paul Colas , David Attie

Muon-Induced X-ray Emission (MIXE) is a non-destructive analytical technique that leverages negative muons to probe elemental and isotopic compositions by detecting characteristic muonic X-rays emitted during atomic cascades and gamma rays…

We describe a high resolution imaging detector based on a single 80 mm micro-channel-plate (MCP) and a phosphor screen mounted on a UHV flange of only 100 mm inner diameter. It relies on standard components and we describe its performance…

Instrumentation and Detectors · Physics 2018-05-30 Sylvain Lupone , Pierre Soulisse , Philippe Roncin

We developed a 2-mm-thick CdTe double-sided strip detector (CdTe-DSD) with a 250 um strip pitch, which has high spatial resolution with a uniform large imaging area of 10 cm$^2$ and high energy resolution with high detection efficiency in…

Instrumentation and Methods for Astrophysics · Physics 2023-12-19 Takahiro Minami , Miho Katsuragawa , Shunsaku Nagasawa , Shin'ichiro Takeda , Shin Watanabe , Yutaka Tsuzuki , Tadayuki Takahashi

Large-size hybrid and pixelized GEM-Micromegas gaseous detectors (40x40 cm$^2$ active area) were developed and installed in 2014 and 2015 for the COMPASS2 physics program which started at the same time. That program involved in particular…

The results of a beam test performed at the KEK PS in June 2005 are presented. Drift properties of an argon-isobutane mixture have been accurately measured and compared with predictions at magnetic fields between 0 and 1 Tesla. The r.m.s.…

Instrumentation and Detectors · Physics 2009-04-17 D. C. Arogancia

The unique electrical and material properties of 4H-silicon-carbide (4H-SiC) make it a promising candidate material for high rate particle detectors. In contrast to the ubiquitously used silicon (Si), 4H-SiC offers a higher carrier…

The performance of pressurized drift-tube detectors at very high background rates has been studied at the Gamma Irradiation Facility (GIF) at CERN and in an intense 20 MeV proton beam at the Munich Van-der-Graaf tandem accelerator for…

This article documents the performance of the ATLAS muon identification and reconstruction using the first LHC dataset recorded at $\sqrt{s}$ = 13 TeV in 2015. Using a large sample of $J/\psi\to\mu\mu$ and $Z\to\mu\mu$ decays from 3.2…

High Energy Physics - Experiment · Physics 2016-05-31 ATLAS Collaboration

We present the performance of Multi-gap timing RPCs under irradiation by fully stripped relativistic ions (gamma*beta=2.7, Z=1-6). A time resolution of 80 ps at high efficiency has been obtained by just using standard `off the shelf' 4-gap…

The demand for a large number of readout channels has been a limiting factor for the application of Micro-pattern Gaseous Detectors (MPGDs) in achieving higher spatial resolution and larger detection areas. This challenge is further…

Instrumentation and Detectors · Physics 2025-05-22 Yu Wang , Shubin Liu , Hao Zhuang , Zhengwu Ding , Zhihang Yao , Changqing Feng , Zhiyong Zhang

For the HERA upgrade, the ZEUS experiment has designed and installed a high precision Micro Vertex Detector (MVD) using single sided micro-strip sensors with capacitive charge division. The sensors have a readout pitch of 120 microns, with…

We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an {\em in situ} calibration mask, an accuracy of 8~$\mu$m and a resolution of…

We present the development and characterization of a compact low-energy ion beam diagnostic for the WISArD (Weak Interaction Studies with $\mathrm{^{32}Ar}$ Decay) experiment at ISOLDE/CERN. The microchannel plate (MCP) detector, which is…

Strip detectors are populating outer trackers of high-energy particle experiments. They are convenient for covering large areas of sensitive material since they use less power and have fewer readout channels compared to pixels sensors.…