Related papers: First polarised light with the NIKA camera
Context. Millimetre-wave astronomy is an important tool for both general astrophysics studies and cosmology. A large number of unidentified sources are being detected by the large field-of-view continuum instruments operating on large…
To obtain full Stokes spectra in multi-wavelength windows simultaneously, we developed a new spectro-polarimeter on the Domeless Solar Telescope at Hida Observatory. The new polarimeter consists of a 60 cm aperture vacuum telescope on an…
We present measurements and simulations of the polarization purity of leaky lens-antenna coupled microwave Kinetic Inductance Detectors (KIDs) at 1.5 THz. We find the integrated cross-polarization level to be at -21.5 dB for 1 f\#$\lambda$…
Generation of particular polarization states of light, encoding information in polarization degree of freedom, and efficient measurement of unknown polarization are the key tasks in optical metrology, optical communications,…
The ability of NICMOS to perform high accuracy polarimetry is currently hampered by an uncalibrated residual instrumental polarization at a level of 1.2-1.5%. To better quantify and characterize this residual we obtained observations of…
The Lightweight Asymmetry and Magnetism Probe (LAMP) is a micro-satellite mission concept dedicated for astronomical X-ray polarimetry and is currently under early phase study. It consists of segmented paraboloidal multilayer mirrors with a…
The B-Machine Telescope is the culmination of several years of development, construction, characterization and observation. The telescope is a departure from standard polarization chopping of correlation receivers to a half wave plate…
We utilize the localization analysis method to precisely determine the light beam positions with the spatial separation beyond the optical diffraction limit. By such a direct spatial measurement, the associated optical setup is built to…
The findings of a nine orbit calibration plan carried out during HST Cycle 15, to fully determine the NICMOS camera 2 (2.0 micron) polarization calibration to high accuracy, are reported. Recently Ueta et al. and Batcheldor et al. have…
Several on-going and future experiments use a Stokes polarimeter (i.e. a rotating wave plate followed by a steady polarizer and by an unpolarized detector) to measure the small polarized component of the Cosmic Microwave Background. The…
We report on the status of an ongoing effort to develop arrays of horn-coupled, polarization-sensitive microwave kinetic inductance detectors (MKIDs) that are each sensitive to two spectral bands between 125 and 280 GHz. These multi-chroic…
We show that it is possible to measure polarization with a polarimeter that gets rid of the seeing while still measuring at a frequency well below that of the seeing. We study a standard polarimeter made of two retarders and a beamsplitter.…
The development of multi-layer optics which allow to focus photons up to 100 keV and more promises an enormous jump in sensitivity in the hard X-ray energy band. This technology is already planned to be exploited by future missions…
In the Square Kilometre Array (SKA) telescope [1], [2], the noise temperature of the first LNA must be reduced in order to reduce the necessary active area and the total system costs. Cooling the LNA locally would significantly decrease the…
Polarized neutrons are a powerful probe to investigate magnetism in condensed matter on length scales from single atomic distances to micrometers. With the ongoing advancement of neutron optics, that allow to transport beams with increased…
An approach for measuring linear X-ray polarization over a broad-band using conventional spectroscopic optics is described. A set of multilayer-coated flats reflect the dispersed X-rays to the instrument detectors. The intensity variation…
This study aims to characterise the polarized foreground emission in the ELAIS-N1 field and to address its possible implications for the extraction of the cosmological 21-cm signal from the Low-Frequency Array - Epoch of Reionization…
XPOL, the first correlation polarimeter at a large millimeter telescope, uses a flexible digital correlator to measure all four Stokes parameters simultaneously, i.e. the total power I, the linear polarization components Q and U, and the…
We present a simple method for controlling the polarisation state of light at the waist of a single-mode optical nanofibre. The method consists of complete polarisation compensation based on imaging scattered light from inherent…
We experimentally observe the dipole scattering of a nanoparticle using a high numerical aperture (NA) imaging system. The optically levitated nanoparticle provides an environment free of particle-substrate interaction. We illuminate the…