Related papers: Beam size and position measurement based on logari…
The new beam position monitor (BPM) system of the injector at the upgrade project of Hefei Light Source (HLS II) has 19 stripline beam position monitors. Most consist of four orthogonal symmetric stripline electrodes. The differences in…
The 4 electrode signals of the beam position detector(BPM) of the STORAGE ring of HEFEI Light Source are directly connected to the domestic oscilloscope with 12bit resolution, 10Gsps sampling rate and 2GHz bandwidth. The acquisition program…
An interferometer system and an imaging system using visible synchrotron radiation (SR) have been installed in HLS II storage ring. Simulations of these two systems are given using Synchrotron Radiation Workshop(SRW) code. With these two…
Transverse 2D phase space distribution of a 2.1 MeV, 5 mA H$^-$ beam is measured at the PIPIT test accelerator at Fermilab with an Allison scanner. The paper describes the design, calibration, and performance of the scanner as well as the…
This contribution presents a novel bunch current measurement system based on an ultra-fast photodetector and a high-speed digitizer at Hefei Light Source II (HLS II). In order to achieve bunch-by-bunch resolution, the sampling rate of the…
As the brightness of synchrotron radiation (SR) light sources improves, the operation stability of light sources is weakened. To explore various beam instability related issues in light sources, one transverse beam diagnostics system for…
This paper evaluates the performance of algorithms suitable to process the measurements from two laser beam metrology systems, in particular with reference to the Gaia Basic Angle Monitoring device. The system and signal characteristics are…
We develop a novel technique to measure small angular and lateral displacements of structured light beams. The technique relies on using high-order Hermite-Gaussian (HG) and Laguerre-Gaussian (LG) modes, which have well-defined symmetry…
The upgrade project of Hefei Light Source storage ring is under way. In this paper, the broadband impedances of resistive wall and coated ceramic vacuum chamber were calculated using the analytic formula, the wake fields and impedances of…
The upgrade project of Hefei Light Source storage ring is under way. In this paper, the wake fields of new designed vacuum chambers have been simulated by CST code, and then broadband impedances were obtained by FFT. Together with resistive…
Hefei Light Source (HLS) is being upgraded to HLS II. Its emittance will be much lower than before, therefore the Touschek scattering will increase significantly and become the dominant factor of beam loss. So it is necessary to build a new…
2D and 4D transverse phase-space of a low-energy ion-beam is measured with two of the most common emittance scanners. The article covers the description of the installation, the setup, the settings, the experiment and the benchmark of the…
Accurate and fast beam-alignment is essential to cope with the fast-varying environment in millimeter-wave communications. A data-driven approach is a promising solution to reduce the training overhead by leveraging side information and…
A simple, analytically correct algorithm is developed for calculating pencil beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The…
The fields produced by a long beam with a given transverse charge distribution in a homogeneous vacuum chamber are studied. Signals induced by a displaced finite-size beam on electrodes of a beam position monitor (BPM) are calculated and…
Particle size measurement based on digital holography with conventional algorithms are usually time-consuming and susceptible to noises associated with hologram quality and particle complexity, limiting its usage in a broad range of…
Beam-line equipment was upgraded for experiment E08-027 (g2p) in Hall A at Jefferson Lab. Two beam position monitors (BPMs) were necessary to measure the beam position and angle at the target. A new BPM receiver was designed and built to…
We present a theoretical analysis of the measuring algorithm we use when applying the Diffracto-Astrometry technique to Hubble Space Telescope Wide Field Planetary Camera 2 (WFPC2) saturated stellar images. Theoretical Point Spread…
Pixelated silicon detectors are state-of-the-art technology to achieve precise tracking and vertexing at collider experiments, designed to accurately measure the hit position of incoming particles in high rate and radiation environments.…
The development of a multiple-channel lock-in optical spectrometer (LIOS) is presented, which enables parallel phase-sensitive detection at the output of an optical spectrometer. The light intensity from a spectrally broad source is…