Related papers: High-Voltage Terminal Test of Test Stand for 1-MV …
A superconducting RF accelerator test facility is being constructed at Fermilab. The existing New Muon Lab (NML) building is being converted for this facility. The accelerator will consist of an electron gun, injector, beam acceleration…
For the CLIC two-beam scheme, a high-current, long-pulse drive beam is required for RF power generation. Taking advantage of the 3 GHz klystrons available at the LEP injector once LEP stops, a 180 MeV electron accelerator is being…
A method of electronic conductivity measurement is presented. It combines two well known methods of electrochemistry: cyclic voltammetry and chronoamperometry. This DC technique uses the Hebb/Wagner approach to block ionic conduction when…
We have recently demonstrated static trapping of ammonia isotopologues in a decelerator that consists of a series of ring-shaped electrodes to which oscillating high voltages are applied [Quintero-P\'{e}rez et al., Phys. Rev. Lett. 110,…
Multiple Electrostatic Quadrupole Array Linear Accelerators (MEQALACs) provide an opportunity to realize compact radio-frequency (RF) accelerator structures that can deliver very high beam currents. MEQALACs have been previously realized…
The bulk irradiation of materials with 10-30 MeV protons promises to advance the study of radiation damage for fission and fusion power plants. Intermediate energy proton beams can now be dedicated to materials irradiation within…
Currently there is a Proposed FNAL 750keV Injector Upgrade for the replacement of the 40 year old Fermi National Laboratory (FNAL) Cockcroft-Walton accelerators with a new ion source and 200MHz Radio Frequency Quadruple (RFQ). The slit type…
The beam-ion interaction is a potential limitation of beam performance in electron accelerators, especially where the beam emittance is of a great concern in future ultra-low emittance light source. "Conventionally", the beam instability…
In accelerators, ion beams are often accelerated using electrostatic accelerating tubes. This paper reports on a method to improve the beam transport efficiency without adding new components to the beam transport system. High beam currents…
A fast-reading current integrator is developed for high time-resolution and low-noise ion beam diagnostics under both continuous-wave and pulsed operating conditions. The system combines a low-leakage transimpedance front-end with a hybrid…
Accelerating structures operating in Ka-Band are foreseen to achieve gradients around 150 MV/m. Among possible applications of a Ka-Band accelerating structure we refer to the beam phase-space manipulation for the Compact Light XLS project…
A new design for heavy-ion beam driven isentropic compression experiments is suggested and analysed. The proposed setup utilises long stopping ranges and the variable focal spot geometry of the high-energy uranium beams delivered at the GSI…
Achieving the highest possible mass resolving power in a multi-reflection time-of-flight mass spectrometer requires very high-stability power supplies. To this end, we have developed a programmable high-voltage power supply that can achieve…
High gradient accelerator injectors have been widely studied throughout the world-leading accelerator facilities. The demand for high frequency cavities have led the Detector, Accelerator and instrumentation laboratory (KAHVELab) in…
We report on the performance of a monitoring system for a prototype calorimeter for the BTeV experiment that uses Lead Tungstate crystals coupled with photomultiplier tubes. The tests were carried out at the 70 GeV accelerator complex at…
Radiation-hard ionization chambers were tested using an intense electron beam from the accelerator test facility (ATF) at the Brookhaven National Laboratory (BNL). The detectors were designed to be used as the basic element for monitoring…
The Electron String type of Ion Sources (ESIS) was developed, constructed and tested first in the Joint Institute for Nuclear Research. These ion sources can be the appropriate sources for production of pulsed C4+ and C6+ ion beams which…
The Acceleration Grid Power Supply of the MITICA test facility in Padova (Italy) is currently under commissioning. The power conversion system, the DC generator, and the High Voltage equipment have been individually commissioned, whereas…
A beam line for electrons with energies in the range of 1 to 45 GeV, low contamination of hadrons and muons and high intensity up to 10^6 per accelerator spill at 27 GeV was setup at U70 accelerator in Protvino, Russia. A beam tagging…
Electron Ion Collider (EIC) is a particle accelerator facility planned for construction at Brookhaven National Laboratory on Long Island, New York by the United States Department of Energy. EIC will provide capabilities of colliding beams…