Related papers: A Batteryless Sensor ASIC for Implantable Bio-impe…
Recent advances in intelligent sensors, microelectronics and integrated circuit, system-on-chip design and low power wireless communication introduced the development of miniaturised and autonomous sensor nodes. These tiny sensor nodes can…
In this paper, a non-invasive inductive link model for an Implantable Biomedical Microsystems (IBMs) such as, a pacemaker to monitor Arrhythmic Patients (APs) in Body Area Networks (BANs) is proposed. The model acts as a driving source to…
Pain is a complex and pervasive condition that affects a significant portion of the population. Accurate and consistent assessment is essential for individuals suffering from pain, as well as for developing effective management strategies…
Photoacoustic imaging has emerged as a powerful, non-invasive modality for various biomedical applications. Conventional photoacoustic systems require contact-based ultrasound detection and expensive and bulky high-power lasers for the…
We present our latest ASIC, which is used for the readout of Cadmium Telluride double-sided strip detectors (CdTe DSDs) and high spectroscopic imaging. It is implemented in a 0.35 um CMOS technology (X-Fab XH035), consists of 64 readout…
This manuscript presented brain-computer interface (STM32 and ADS1299) with the embedded board with sensors to monitor the subject's state and environment. To reduce power consumption and device size, we used sensors made in…
Dermal interstitial fluid (ISF) is a rich source of biomarkers (e.g., glucose) that can be used for continuous health monitoring with wearable sensors. Hollow microneedle devices are a promising solution to extract ISF on demand by…
A research of inductive conductometric cell is presented. An equivalent circuit and a mathematical model of inductive cell are given in the article. The model takes into account sample-coil capacity (i.e. capacity formed by the coil and the…
A liquid isooctane (C$_{8}$H$_{18}$) filled ionization linear array for radiotherapy quality assurance has been designed, built and tested. The detector consists of 128 pixels, each of them with an area of 1.7 mm $\times$ 1.7 mm and a gap…
The magnetic-field behaviour of the off-diagonal impedance in Co-based amorphous wires is investigated under the condition of sinusoidal (50 MHz) and pulsed (5 ns rising time) current excitations. For comparison, the field characteristics…
In ion cancer therapy, high-intensity ion beams are used to treat tumors by taking advantage of the Bragg-Peak. Typical ion therapy centers use particle rates up to $10^{10}$ ions/second for treatment. On the other hand, such intensities…
Biological tissue integrity is actively maintained by cells. It is essential to comprehend how cells accomplish this in order to stage tissue diseases. However, addressing the complexity of a cell's system of interrelated mechanisms poses a…
A 64-channel mixed-mode ASIC, suitable for particle detectors of large dynamic range and high capacitance up to hundreds of pF, is presented here. Each channel features an analogue front-end for signal amplification and filtering, and a…
Stress is a complex issue with wide-ranging physical and psychological impacts on human daily performance. Specifically, acute stress detection is becoming a valuable application in contextual human understanding. Two common approaches to…
Label-free biosensors, including conventional quartz-crystal-microbalance (QCM) biosensor, are seriously affected by nonspecific adsorption of contaminants involved in analyte solution, and it is exceptionally difficult to extract the…
We characterize a new x-ray Mixed-Mode Pixel Array Detector (MM-PAD-2.1) Application Specific Integrated Circuit (ASIC). Using an integrating pixel front-end with dynamic charge removal architecture, the MM-PAD-2.1 ASIC extends the maximum…
We present a compact, noise-resilient reconstructive spectrometer-on-a-chip that achieves high-resolution hyperspectral imaging across an extended near-infrared (NIR) range up to 1100nm. The device integrates monolithically fabricated…
The design of devices based on acoustic or optical fields requires the fabrication of cavities and structures capable of efficiently trapping these waves. A special type of cavity can be designed to support resonances with a theoretically…
We numerically design a hybrid plasmonic dielectric refractive index biosensor comprising ametal insulator metal (MIM) bus waveguide evanescently coupled to a silicon core resonator. The geometry is optimized with a genetic algorithm (GA)…
Magnetoimpedance, MI, change due to surface modification of the sensitive element caused by biofluids was studied with the aim of creating a robust sensor capable of separating the chemical surface modification from the sensing process. A…