English
Related papers

Related papers: Phase Analysis for Frequency Standards in the Micr…

200 papers

We describe a measurement of the frequency of the 2S1/2(F = 0) - 2D3/2(F' = 2) transition of 171Yb+ at the wavelength 436 nm (frequency 688 THz), using a single Yb+ ion confined in a Paul trap and two caesium fountains as references. In one…

Atomic Physics · Physics 2014-02-21 Chr. Tamm , N. Huntemann , B. Lipphardt , V. Gerginov , N. Nemitz , M. Kazda , S. Weyers , E. Peik

We evaluate the frequency error from distributed cavity phase in the caesium fountain clock PTB-CSF2 at the Physikalisch-Technische Bundesanstalt with a combination of frequency measurements and ab initio calculations. The associated…

Atomic Physics · Physics 2018-10-22 S. Weyers , V. Gerginov , N. Nemitz , R. Li , K. Gibble

We describe an optical frequency stabilization scheme of a microwave oscillator that is used for the interrogation of primary caesium fountain clocks. Because of its superior phase noise properties, this scheme, which is based on an…

Atomic Physics · Physics 2018-10-22 Burghard Lipphardt , Vladislav Gerginov , Stefan Weyers

Improvements of the systematic uncertainty, frequency instability, and long-term reliability of the two caesium fountain primary frequency standards CSF1 and CSF2 at PTB (Physikalisch-Technische Bundesanstalt) are described. We have further…

Atomic Physics · Physics 2018-10-22 S. Weyers , V. Gerginov , M. Kazda , J. Rahm , B. Lipphardt , G. Dobrev , K. Gibble

The short-term stability of passive atomic frequency standards, especially in pulsed operation, is often limited by local oscillator noise via intermodulation effects. We present an experimental demonstration of the intermodulation effect…

Atomic Physics · Physics 2007-07-25 Jocelyne Guéna , Gregor Dudle , Pierre Thomann

We report on a theoretical analysis of the phase-shift in compact atomic clocks working either with cold or thermal atoms. It is well known that in a microwave cavity with electromagnetic losses, a traveling wave adds to the standing wave…

Atomic Physics · Physics 2017-05-04 Aldo Godone , Salvatore Micalizio

We use an atomic fountain clock to measure quantum scattering phase shifts precisely through a series of narrow, low-field Feshbach resonances at average collision energies below $1\,\mu$K. Our low spread in collision energy yields phase…

Atomic Physics · Physics 2017-09-19 Aaron Bennett , Kurt Gibble , Servaas Kokkelmans , Jeremy M. Hutson

A caesium fountain clock is operated utilizing a microwave oscillator that derives its frequency stability from a stable laser by means of a fiber-laser femtosecond frequency comb. This oscillator is based on the technology developed for…

Atomic Physics · Physics 2018-10-22 S. Weyers , B. Lipphardt , H. Schnatz

This paper describes advances in microwave frequency standards using laser-cooled atoms at BNM-SYRTE. First, recent improvements of the $^{133}$Cs and $^{87}$Rb atomic fountains are described. Thanks to the routine use of a cryogenic…

Timescale comparison between optical atomic clocks over ground-to-space and terrestrial free-space laser links will have enormous benefits for fundamental and applied science, from measurements of fundamental constants and searches for dark…

We report the realisation and preliminary study of a frequency standard using a fountain of laser cooled caesium atoms. Our apparatus uses a magneto-optical trap as a source of cold atoms and optical pumping to prepare the atoms in the…

Quantum Physics · Physics 2007-05-23 A. Michaud , M. Chowdhury , K. P. Zetie , C. J. Cooper , G. Hillenbrand , V. Lorent , A. Steane , C. J. Foot

We evaluate the distributed cavity phase and microwave lensing frequency shifts, which were the two largest sources of uncertainty for the NPL-CsF2 cesium fountain clock. We report measurements that confirm a detailed theoretical model of…

Quantum Physics · Physics 2011-08-30 Ruoxin Li , Kurt Gibble , Krzysztof Szymaniec

Precision comparisons of different atomic frequency standards over a period of a few years can be used for a sensitive search for temporal variations of fundamental constants. We present recent frequency measurements of the 688 THz…

Atomic Physics · Physics 2008-11-25 E. Peik , B. Lipphardt , H. Schnatz , Chr. Tamm , S. Weyers , R. Wynands

In this paper we report the evaluation of an optical lattice clock based on neutral mercury down to a relative uncertainty of $1.7\times 10^{-16}$. Comparing this characterized frequency standard to a Cs atomic fountain we determine the…

The comparison of different atomic transition frequencies over time can be used to determine the present value of the temporal derivative of the fine structure constant alpha in a model-independent way without assumptions on constancy or…

Atomic Physics · Physics 2009-11-10 E. Peik , B. Lipphardt , H. Schnatz , T. Schneider , Chr. Tamm , S. G. Karshenboim

The frequency comb created by a femtosecond mode-locked laser and a microstructured fiber is used to phase coherently measure the frequencies of both the Hg^+ and Ca optical standards with respect to the SI second as realized at NIST. We…

Optical atomic clocks are poised to redefine the SI second, thanks to stability and accuracy more than one hundred times better than the current microwave atomic clock standard. However, the best optical clocks have not seen their…

Measurements of the birefringence of a single atom strongly coupled to a high-finesse optical resonator are reported, with nonlinear phase shifts observed for intracavity photon number much less than one. A proposal to utilize the measured…

Quantum Physics · Physics 2009-10-28 Q. A. Turchette , C. J. Hood , W. Lange , H. Mabuchi , H. J. Kimble

We investigate the magnetic-field-induced frequency shift (MFS) of the clock "0-0" transition in the microwave quantum frequency standard (atomic clock) based on coherent population trapping (CPT) in $^{87}$Rb vapor. To scan the CPT…

Atomic Physics · Physics 2025-04-28 V. I. Vishnyakov , D. V. Brazhnikov , M. N. Skvortsov

We propose the mechanism of active Faraday optical clock, and experimentally demonstrate active Faraday optical frequency standards based on 852 nm narrow bandwidth Faraday atomic filter by the method of velocity-selective optical pumping…

Atomic Physics · Physics 2014-11-03 Wei Zhuang , Jingbiao Chen
‹ Prev 1 2 3 10 Next ›