English
Related papers

Related papers: Level-1 pixel based tracking trigger algorithm for…

200 papers

The tracking system of the CMS experiment, currently under construction at the Large Hadron Collider (LHC) at CERN (Geneva, Switzerland), will include a silicon pixel detector providing three spacial measurements in its final configuration…

During the High Luminosity phase of LHC, up to 200 proton-proton collisions per bunch crossing will bring severe challenges for event reconstruction. To mitigate pileup effects, an extended upgrade program of the CMS experiment is expected.…

High Energy Physics - Experiment · Physics 2026-03-23 Simona Palluotto

The hit combinatorial problem is a main challenge for track reconstruction and triggering at high rate experiments. At hadron colliders the dominant fraction of hits is due to low momentum tracks for which multiple scattering (MS) effects…

Instrumentation and Detectors · Physics 2015-06-22 Andre Schöning

Significant new challenges are continuously confronting the High Energy Physics (HEP) experiments, in particular the two detectors at the Large Hadron Collider (LHC) at CERN, where nominal conditions deliver proton-proton collisions to the…

Instrumentation and Detectors · Physics 2013-10-24 V. Halyo , A. Hunt , P. Jindal , P. LeGresley , P. Lujan

CMOS pixel sensors (CPS) represent a novel technological approach to building charged particle detectors. CMOS processes allow to integrate a sensing volume and readout electronics in a single silicon die allowing to build sensors with a…

The Muon Spectrometer (MS) of the ALICE experiment at LHC is equipped with a HLT (High Level Trigger), whose aim is to improve the accuracy of the trigger cuts delivered at the L0 stage. A computational challenge of real-time event…

Instrumentation and Detectors · Physics 2015-03-19 Indranil Das

The Data Quality Monitoring (DQM) of the Compact Muon Solenoid (CMS) silicon tracking detectors (Tracker) at the Large Hadron Collider (LHC) at CERN is a software based system designed to monitor the detector and reconstruction performance,…

Instrumentation and Detectors · Physics 2019-08-13 V. Adler

In the first LHC running period the CMS-pixel detector had to face various operational challenges and had to adapt to the rapidly changing beam conditions. In order to maximize the physics potential and the quality of the data, online and…

Instrumentation and Detectors · Physics 2015-06-11 János Karancsi

The pixel detector is the innermost tracking device of the CMS experiment at the LHC. It is built from two independent sub devices, the pixel barrel and the end disks. The barrel consists of three concentric layers around the beam pipe with…

Instrumentation and Detectors · Physics 2008-11-26 H. Chr. Kästli , W. Bertl , W. Erdmann , K. Gabathuler , Ch. Hörmann , R. Horisberger , S. König , D. Kotlinski , B. Meier , P. Robmann , T. Rohe , S. Streuli

After 2001 the upgraded ep collider HERA will provide an about five times higher luminosity for the two experiments H1 and ZEUS. In order to cope with the expected higher event rates the H1 collaboration is building a track based trigger…

High Energy Physics - Experiment · Physics 2014-11-17 A. Baird , E. Elsen , Y. H. Fleming , M. Kolander , S. Kolya , D. Meer , D. Mercer , J. Naumann , P. R. Newman , D. Sankey , A. Schoening , H. -C. Schultz-Coulon , Ch. Wissing

The CMS muon system operates gas-based detectors. Upgrades of the detectors and trigger components are needed to cope with increasingly challenging conditions of the HL-LHC. New irradiation tests are performed to ensure that the muon…

Instrumentation and Detectors · Physics 2018-09-07 Jian Wang

Significant progress has been made to develop silicon pixel technologies for use in the vertex and tracker regions of the proposed Compact Linear Collider (CLIC) detector design. The electron-positron collisions generated by this linear…

Instrumentation and Detectors · Physics 2020-04-22 Morag Williams

The Pixel Luminosity Telescope is a silicon pixel detector dedicated to luminosity measurement at the CMS experiment at the LHC. It is located approximately 1.75 m from the interaction point and arranged into 16 "telescopes", with eight…

Instrumentation and Detectors · Physics 2023-08-02 Paul Lujan

As part of the Phase II upgrade program, the Compact Muon Solenoid (CMS) detector will incorporate a new timing layer designed to measure minimum ionizing particles (MIPs) with a time resolution of $\sim$30 ps. Precision timing will…

Instrumentation and Detectors · Physics 2018-11-27 Olmo Cerri

We investigate the physics case for a dedicated trigger on a low mass, hadronic displaced vertex at the high luminosity LHC, relying on the CMS phase II track trigger. We estimate the trigger efficiency with a simplified simulation of the…

High Energy Physics - Phenomenology · Physics 2021-11-03 Yuri Gershtein , Simon Knapen , Diego Redigolo

In order to fully exploit the physics potential of the future high energy e+e- linear collider, a Vertex Tracker able to provide particle track extrapolation with very high resolution is needed. Hybrid Si pixel sensors are an attractive…

High Energy Physics - Experiment · Physics 2010-01-26 M. Battaglia , S. Borghi , R. Campagnolo , M. Caccia , W. Kucewicz , P. Jalocha , J. Palka , A. Zalewska

The physics aims at the proposed future CLIC high-energy linear $e^+ e^-$ collider pose challenging demands on the performance of the detector system. In particular the vertex and tracking detectors have to combine precision measurements…

Instrumentation and Detectors · Physics 2019-09-04 Mathieu Benoit

The determination of charged particle trajectories (tracking) in collisions at the CERN Large Hadron Collider (LHC) is one of the most important aspects for event reconstruction at hadron colliders. This is especially true in the high…

Instrumentation and Detectors · Physics 2022-12-06 H. Abidi , A. Boveia , V. Cavaliere , D. Furletov , A. Gekow , C. W. Kalderon , S. Yoo

The CMS muon system at the LHC is built of different detector technologies. The measurement of the background hit rates in the different muon detectors during the LHC Run-2 is of prime importance for an assessment of the longevity of the…

Instrumentation and Detectors · Physics 2020-04-22 Silvia Costantini

To extend the physics reach of the LHC, accelerator upgrades are planned which will increase the integrated luminosity to beyond 3000 fb^-1 and the pile-up per bunch-crossing by a factor 5 to 10. To cope with the increased occupancy and…

Instrumentation and Detectors · Physics 2015-06-17 G. Calderini
‹ Prev 1 4 5 6 7 8 10 Next ›