Related papers: RF front-end design and simulation for Sub-picosec…
With electron beam durations down to femtoseconds and sub-femtoseconds achievable in current state-of-the-art accelerators, longitudinal bunch length diagnostics with resolution at the attosecond level are required. In this paper, we…
The Fermilab Linac delivers 400MeV, 25mA H$^-$; beam. The longitudinal bunch parameters are reconstructed using a Bunch Shape Monitor (BSM) installed in the middle of the Linac. For that, the bunch length is measured as a function of the…
The CMS Beam Conditions and Radiation Monitoring System, BRM, will support beam tuning, protect the CMS detector from adverse beam conditions, and measure the accumulated dose close to or inside all sub-detectors. It is composed of…
The early stages of most particle accelerator chains produce sub-ns bunches with velocities in the range of 1 to 20% of the speed of light. Fast Faraday Cups (FFC) are designed to measure the longitudinal charge distribution of these short…
The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring…
Longitudinal bunch profile monitoring is a crucial diagnostic requirement in most accelerator facilities. This is particularly true in modern free-electron lasers and novel acceleration schemes, where bunch lengths are often <100 fs and…
In a typical multi-standard military communication receiver, fast and reliable spectrum sensing unit is required to extract the information of multiple channels (frequency bands) present in a wideband input signal. In this paper, an energy…
We measure the fluorescence spectrum of broadband emitters in an open optical microcavity with radius of curvature R = 17.7(3) um and finesse F ~= 1000. This geometry enables a combined measurement of emission spectra versus cavity length,…
Modern accelerator front ends almost exclusively include radio-frequency quadrupoles for initial capture and focusing of the low-energy beam. Dynamics in the RFQ define the longitudinal bunch parameters. Simulation of the SNS RFQ with…
A conceptual design work and a basic experimental study of a new beam profile monitor have been performed. The monitor will be used to measure emittance of an electron beam in the ATF damping ring at KEK, in which the transverse beam size…
The extremely low dark current of silicon carbide (SiC) detectors, even after high-fluence irradiation, was utilized to develop a beam monitoring system for a wide range of particle rates, i.e., from the kHz to the GHz regime. The system is…
We consider a scheme to generate sub-picosecond electron bunch in the photocathode rf gun by improving the acceleration gradient in the gun, suitably tuning the bunch charge, the laser spot size and the acceleration phase, and reducing the…
The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end…
Ultralow emittance ($\leq20$ nm, normalized) electron beams with $10^5$ electrons per bunch are obtained by tightly focusing an ultrafast ($\sim$ 100 fs) laser pulse on the cathode of a 1.6 cell radiofrequency photoinjector. Taking…
A new bunch length measurement method based on high order mode cavity was proposed. Operating the harmonic cavity at mode TM0n0 so that its radius could be chosen, in order to break the limitation of beam pipe radius. A two-cavity bunch…
Cavity-based quantum node is a competitive platform for distributed quantum networks. Here, we characterize a high-finesse Fabry-Perot optical resonator for coupling single or few atomic quantum registers. Our cavity consists of two mirrors…
In this paper, we present the design and preliminary performance evaluation of a new heavy-ion detector for direct measurements of heavy {\Lambda} hypernuclei lifetime. The detector employs the previously developed 10 picosecond resolution…
Spectrum sensing is a fundamental component of cognitive radio. How to promptly sense the presence of primary users is a key issue to a cognitive radio network. The time requirement is critical in that violating it will cause harmful…
We present a high efficiency source of picosecond pulses derived from a dual cavity optical frequency comb generator. This approach overcomes the limitations of single cavity comb generators that are restricted to efficiencies of a few…
Real-time, bunch-by-bunch monitoring of transverse position, longitudinal phase, and bunch length is crucial for beam control in diffraction-limited storage rings, where complex collective dynamics pose unprecedented diagnostic challenges.…