Related papers: Quantitative Analysis and Efficiency Study of PSD …
The response of a scintillation detector with a cylindrical 1.5-inch LaBr3:Ce crystal to incident neutrons has been measured in the energy range En = 2-12 MeV. Neutrons were produced by proton irradiation of a Li target at Ep = 5-14.6 MeV…
Solid-state scintillators are widely used in particle and applied physics due to their versatility and resistance to diverse environments and operating conditions. This broad range of applications calls for thorough characterization of…
We constructed a neutron calibration facility based on a 300-mCi Am-Be source in conjunction with a search for weakly interacting massive particle candidates for dark matter. The facility is used to study the response of CsI(Tl) crystals to…
Using highly monochromatic synchrotron X-rays in the energy range from 10.5 keV to 100 keV the temperature dependence of nonproportionality and energy resolution of LaBr3 scintillators doped with 5% Ce3+ were studied at 80K, 295K, and 450K.…
The Cs$_2$LiYCl$_6$:Ce (CLYC) elpasolite scintillator is known for its response to fast and thermal neutrons along with good $\gamma$-ray energy resolution. While the $^{35}$Cl($n,p$) reaction has been identified as a potential means for…
High-purity germanium detectors are widely used in rare-event searches due to their excellent energy resolution and extremely high intrinsic (radio)purity. In experiments searching for neutrinoless double beta decay in $^{76}$Ge such as…
Plastic scintillators detectors (PSDs) have been studied as dosimeters, since they provide a cost-effective alternative to conventional ionization chambers. Measurement and analysis of energy dependency were performed on a Siemens Mammomat…
Particle identification using the energy loss in silicon detectors is a powerful technique for probing the Standard Model (SM) as well as searching for new particles beyond the SM. Traditionally, such techniques use the truncated mean of…
We report on a highly selective experimental setup for particle-$\gamma$ coincidence experiments at the Super-Enge Split-Pole Spectrograph (SE-SPS) of the John D. Fox Superconducting Linear Accelerator Laboratory at Florida State University…
Raman spectroscopy can be used to identify molecules such as DNA by the characteristic scattering of light from a laser. It is sensitive at very low concentrations and can accurately quantify the amount of a given molecule in a sample. The…
This paper describes the implementation and performance of CsI(Tl) pulse shape discrimination for the Belle II electromagnetic calorimeter, representing the first application of CsI(Tl) pulse shape discrimination for particle identification…
Plastic scintillation detectors represent an efficient, cost-effective, customizable solution for assessment of gamma radiation fields in the context of nuclear security, environmental radiation survey, radiological and nuclear incidents…
In this paper, we explore the optimization of metal recycling with a focus on real-time differentiation between alloys of copper and aluminium. Spectral data, obtained through Prompt Gamma Neutron Activation Analysis (PGNAA), is utilized…
The ALICE collaboration is proposing a completely new detector, ALICE 3, for operation during the LHC Runs 5 and 6. One of the ALICE~3 subsystems is the Muon IDentifier detector (MID), which has to be optimised to be efficient for the…
The scintillation mechanism in NaI:Tl crystals produces different pulse shapes that are dependent on the incoming particle type. The time distribution of scintillation light from nuclear recoil events decays faster than for electron recoil…
A new Digital Pulse Processing (DPP) system, based on domino ring sampler version 4 (DRS4), with good time resolution for the LaBr3 detectors has been developed and different digital timing analysis methods for processing the detector raw…
The summation amplitude of coincident pulses (SACP) method which is optimal solution to reduce compton scatter phenomenon and pairs phenomenon in the gamma spectra of nuclei decay gamma cascades was used. In the 1982, in comparision with…
Low noise CCDs fully-depleted up to 675 micrometers have been identified as a unique tool for Dark Matter searches and low energy neutrino physics. The charge collection efficiency (CCE) for these detectors is a critical parameter for the…
Performance of a simple method of particle identification via pulse rise time discrimination is demonstrated for slow pulses from charge-sensitive preamplifiers with rise times ranging from 10 ns to 500 ns. The method is based on a…
GAGG(Ce) is a novel scintillator with a fast response and high light output without a hygroscopic nature. It is expected to be a useful detector for charged particles at high-counting rates. However, the response of the GAGG(Ce)…