Related papers: Aging effect in the BESIII drift chamber
Accurate tracking of the internal electrochemical states of lithium-ion battery during cycling enables advanced battery management systems to operate the battery safely and maintain high performance while minimizing battery degradation. To…
With the constant increase of accelerator luminosity, the rate requirements of the MRPC detectors become important. In the same time, aging problem of the detector has to be studied meticulously. An online aging test system is set up in our…
The Muon Detector of the HERA-B experiment at DESY is a gaseous detector that provides muon identification in a high-rate hadronic environment. We present our studies on the properties of several fast gases, Ar/CF4/CH4 (74:20:6), Ar/CF4/CH4…
The performance of a novel tracking detector developed for the focal plane of the NSCL/FRIB S800 magnetic spectrometer is presented. The detector comprises a large-area drift chamber equipped with a hybrid Micro-Pattern Gaseous Detector…
Preliminary test results on microscope investigation and BESIII-type RPC aging performance have revealed interesting aging phenomena that had not been seen before in Linseed oil coated Italian-type RPC. We report here on the aging…
We discuss the long term behaviour of trap models on the integers with asymptotically vanishing drift, providing scaling limit theorems and ageing results. Depending on the tail behaviour of the traps and the strength of the drift, we…
Beam Drift Chamber (BDC) is designed to reconstruct the trajectories of incident rare isotope beams provided by RAON (Rare isotope Accelerator complex for ON-line experiments) into the experimental target of LAMPS (Large Acceptance…
We present recent results of an extensive aging test, performed at the CERN Gamma Irradiation Facility on two single--gap RPC prototypes, developed for the LHCb Muon System. With a method based on a model describing the behaviour of an RPC…
We first introduce the design parameters of the Beijing Electron-Positron Collider II (BEPCII) and the simulation study of beam-beam effects during the design process of the machine. The main advances since 2007 are briefly introduced and…
The HERA-B Outer Tracker is a large system of planar drift chambers with about 113000 read-out channels. Its inner part has been designed to be exposed to a particle flux of up to 2.10^5 cm^-2 s^-1, thus coping with conditions similar to…
We demonstrate that elastic scattering between dark matter (DM) and baryons can affect the thermal evolution of the intergalactic medium at early epochs and discuss the observational consequences. We show that, due to the interaction…
This thesis reports the various phases of the life cycle of a cylindrical GEM detector, developed within the context of the CGEM-IT project. This represents the Italian proposal for the upgrade of the BESIII inner tracker, which has been…
For the muon spectrometer of the ATLAS detector at the large hadron collider (LHC), large drift chambers consisting of 6 to 8 layers of pressurized drift tubes are used for precision tracking covering an active area of 5000 m2 in the…
The integrated luminosities of the data samples collected in the BESIII experiment in 2016--2017 at center-of-mass energies between 4.19 and 4.28 GeV are measured with a precision better than 1% by analyzing large-angle Bhabha scattering…
Bubble Chambers provided the dominant particle detection technology in accelerator experiments for several decades, eventually falling into disuse with the advent of other techniques. We report here on the first period of operation of an…
The role of counter-rotating oscillators in an ensemble of coexisting co- and counter-rotating oscillators is examined by increasing the proportion of the latter. The phenomenon of aging transition was identified at a critical value of the…
Using about $226\times 10^6$ $\jpsi$ events and $106\times 10^6$ $\psi^{\prime}$ events collected with the BESIII detector at the BEPCII $e^+e^-$ collider, the Dalitz plot of $\etap \to \eta \pi^+ \pi^-$ decay is studied, the direct…
The resolution and efficiency of a precision drift-tube chamber for the ATLAS muon spectrometer with final read-out electronics was tested at the Gamma Irradiation Facility at CERN in a 100 GeV muon beam and at photon irradiation rates of…
Using $(1310.6 \pm 7.0) \times 10^{6}~J/\psi$ events acquired with the BESIII detector at the BEPCII storage rings, the decay $\eta^\prime\rightarrow\pi^+\pi^-\mu^+\mu^-$ is observed for the first time with a significance of 8$\sigma$ via…
A detailed study of charge collection efficiency has been performed on the Silicon Drift Detectors (SDD) of the ALICE experiment. Three different methods to study the collected charge as a function of the drift time have been implemented.…