English
Related papers

Related papers: Study of a MA-loaded cavity for compact synchrotro…

200 papers

The cavity perturbation technique is an extremely powerful method for measuring the electrodynamic response of a material in the millimeter- and sub-millimeter spectral range (10 GHz to 1 THz), particularly in the case of…

Other Condensed Matter · Physics 2007-05-23 Susumu Takahashi , Stephen Hill

The DeeMe experiment to search for muon-to-electron conversions with a sensitivity 10--100 times better than those achieved by previous experiments is in preparation at the Japan Proton Accelerator Research Complex. The magnetic…

Instrumentation and Detectors · Physics 2021-02-01 N. Teshima , M. Aoki , Y. Higashino , H. Ikeuchi , K. Komukai , D. Nagao , Y. Nakatsugawa , H. Natori , Y. Seiya , N. M. Truong , K. Yamamoto

Magnetrons are widely used as high-performance microwave sources in microwave heating, microwave chemistry, and microwave power transmission due to their high efficiency, low cost, and compact size advantages. However, the output power of a…

Applied Physics · Physics 2025-12-09 Shaoyue Wang , Xu Zhu , Xiaojie Chen , Da He , Zhongqi He , Liping Yan , Changjun Liu

(abridged) We report on multi-wavelength measurements of Swift J1753.5-0127 in the hard state at L=2.7e36 erg/s (assuming d=3 kpc) in 2014. The radio emission is optically thick synchrotron, presumably from a compact jet. We take advantage…

We propose to use slow muons facilities combined with cyclotron radiation detection for precision test of the weak interaction in the muon decays. Slow positive muon bunches are first injected into a cylindrical superconducting vacuum…

Instrumentation and Detectors · Physics 2024-01-12 Xin Chen , Zhen Hu , Hui Li , Shaogang Peng , Yongcheng Wu

A low-cost and simple setup for measuring the high-frequency hysteresis loops of magnetic samples is described. An AMF in the range 6-100 kHz with amplitude up to 80 mT is produced by a Litz wire coil. The latter is air-cooled using a…

Materials Science · Physics 2015-06-22 V. Connord , B. Mehdaoui , R. P. Tan , J. Carrey , M. Respaud

The higher efficiency of superconducting radio-frequency (SRF) cavities compared to normal-conducting ones enables the development of high-energy continuous-wave linear accelerators (linacs). Recent progress in the development of…

Building a \BBz experiment with the ability to probe neutrino mass in the inverted hierarchy region requires the combination of a large detector mass sensitive to \BBz, on the order of 1-tonne, and unprecedented background levels, on the…

Nuclear Experiment · Physics 2019-08-13 S. R. Elliott

The realization of photonic microwave oscillators using optomechanical cavities has recently become a reality. By pumping the cavity with a blue-detuned laser, the so-called phonon lasing regime - in which a mechanical resonance is…

In frame of the development of a high resolution BPM system for the CLIC Main Linac we present the design of a cavity BPM prototype. It consists of a waveguide loaded dipole mode resonator and a monopole mode reference cavity, both…

Accelerator Physics · Physics 2012-07-20 N. Chritin , H. Schmickler , L. Soby , A. Lunin , N. Solyak , M. Wendt , V. Yakovlev

Cavity optomechanical magnetic field sensors, constructed by coupling a magnetostrictive material to a micro-toroidal optical cavity, act as ultra-sensitive room temperature magnetometers with tens of micrometre size and broad bandwidth,…

Applied Physics · Physics 2020-08-18 Yimin Yu , Stefan Forstner , Halina Rubinsztein-Dunlop , Warwick P. Bowen

In the context of axion search with haloscopes, tunable cavity resonators with high quality factor and high effective volume at frequencies above about 8 GHz are central for probing the axion-photon coupling with the required sensitivity to…

Instrumentation and Detectors · Physics 2024-10-11 R. Di Vora , A. Gardikiotis , C. Braggio , G. Carugno , A. Lombardi , A. Ortolan , G. Ruoso

Monolithic Active Pixel Sensors (MAPS) have been developed since the late 1990s based on silicon substrates with a thin epitaxial layer (thickness of 10-15 $\mu$m) in which charge is collected on an electrode, albeit by disordered and slow…

Magneto-optical traps on atom chips are usually restricted to small atomic samples due to a limited capture volume caused primarily by distorted field configurations. Here we present a magneto-optical trap with minimized distortions based…

A new experimental area designed to develop, test and verify muon ionization cooling apparatus using the 400-MeV Fermilab Linac proton beam has been fully installed and is presently being commissioned. Initially, this area was used for…

We generalize the momentum average (MA) approximation to study the properties of models with momentum-dependent electron-phonon coupling. As in the case of the application of the original MA to the Holstein model, the results are…

Strongly Correlated Electrons · Physics 2009-11-13 Glen L. Goodvin , Mona Berciu

To achieve the true diffraction-limited emittance of a storage ring light source, such as ~10 pm.rad for medium-energy electron beams, within a limited circumference, it is generally necessary to increase the number of bending magnets in a…

Accelerator Physics · Physics 2023-08-22 Zhiliang Ren , Zhenghe Bai , Penghui Yang , Lin Wang , Hongliang Xu

The NO{\nu}A Experiment will construct a detector optimized for electron neutrino detection in the existing Neutrino at Main Injector (NuMI) beamline. This beamline is capable of operating at 400 kW of primary beam power and the upgrade…

Accelerator Physics · Physics 2012-07-18 C. Ader , D. W. Wildman

We propose to model the uppermost inner core as an aggregate of randomly oriented anisotropic ``patches''. A patch is defined as an assemblage of a possibly large number of crystals with identically oriented crystallographic axes. This…

Geophysics · Physics 2008-12-18 Marie Calvet , Ludovic Margerin

The 10 MeV accelerator-driven subcritical system (ADS) Injector-I test stand at Institute of High Energy Physics (IHEP) is a testing facility dedicated to demonstrate one of the two injector design schemes [Injector Scheme-I, which works at…