The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well…
We report on progress in the development of the LSTFE2 prototype front-end ASIC geared towards the readout of silicon microstrip sensors in a Linear Collider detector. We also discuss progress in the design of the back-end digital…
This paper presents the design, implementation, and performance evaluation of LUCAS, a low-power, ultra-low jitter ASIC optimized for SiPM readout in Time-of-Flight Computed Tomography (ToF-CT) applications. Leveraging a novel preamplifier…
We develop the vertex detector for the international linear collider (ILC) using the FPCCD (Fine Pixel CCD), whose pixel size is 5 x 5 um2. Together with the FPCCD sensor, a prototype of the readout ASIC was developed in 2008. The readout…
High-speed imaging of cells in flow is essential for probing cellular heterogeneity in large populations. Existing imaging approaches based on single-pixel detection and spatio-temporal encoding provide exceptional speed, but typically rely…
Recent years have shown an increased use of silicon photo-multipliers (SiPM) in experiments as they are of reasonable cost, have relatively low power consumption and are easily available in a variety of form factors allowing for a large…
First of its kind, the barrel section of the MIP Timing Detector is a large area timing detector based on LYSO:Ce crystals and SiPMs which are required to operate in an unprecedentedly harsh radiation environment (up to an integrated…
A large area Resistive Plate Chamber (RPC) with a total active surface of 160x10 cm2 was built and tested. The surface was segmented in two 5 cm wide strips readout on both ends with custom, very high frequency, front end electronics. A…
The DESY II Test Beam Facility is a key infrastructure for modern high energy physics detector development, providing particles with a small momentum spread in a range from 1 to 6 GeV to user groups e.g. from the LHC experiments and Belle…
In 2019, the LHCb experiment at CERN will undergo a major upgrade where its detector electronics and the entire readout system will be replaced. The goal is to read-out all events at the full LHC frequency of 40 MHz, reaching a total data…
The Analog Pipeline Chip (APC) is a low noise, low power readout chip for silicon micro strip detectors with 128 channels containing an analog pipeline of 32 buffers depth. The chip has been designed for operation at HERA with a power…
Development of the Silicon photomultiplier Elementary Cell Add-on camera (SiECA) has provided extensive information regarding the use of SiPMs for future cosmic ray detection systems. We present the technical aspects of sensor readout…
This paper describes a new method for optical readout of Time Projection Chambers (TPCs), based on the Linearly Graded Silicon Photomultiplier (LG-SiPM). This is a single photon-sensitive detector with excellent timing and 2D position…
Large area LaBr3:Ce detectors with a SiPM array readout have been developed for the FAMU experiment at RAL. The aim was to have a good energy resolution for low energy X-rays detection (around 100 keV) and good timing properties of the…
The broad energy response, low electronic read noise, and good energy resolution have made X-ray Charge-Coupled Devices (CCDs) an obvious choice for developing soft X-ray astronomical instruments over the last half century. They also come…
CEPC (Circular Electron and Positron Collider) is a large experiment facility proposed by Chinese particle physics community. One of its running option is being the Higgs factory. Calorimeter is the main part of this experiment to measure…
Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…
Compact X-rays detectors made of 1/2" or 1" :LaBr3:Ce crystals of cubic shape with SiPM array readout have been developed for the FAMU experiment at RIKEN-RAL. The aim is a precise measurement of the proton Zemach radius with incoming…
This paper presents a novel pixel chip readout scheme: the Region-of-Interest Readout Circuit (ROIRC), which is designed for large area, large array pixel chips and Gas Pixel Detector (GPD). This design employs a sentinel pixel detection…
We first briefly describe the history and motivation behind Cherenkov and scintillation light detection. We then discuss the instrumentation needed to detect these photons as it applies to both photodetectors and readout electronics. One of…