English
Related papers

Related papers: Index of refraction, Rayleigh scattering length, a…

200 papers

As liquid xenon TPCs increase in target mass while pursuing the direct detection of WIMP dark matter, the technical challenges arising due to their size call for new solutions and open the discussion on alternative detector concepts.…

Instrumentation and Detectors · Physics 2022-04-14 Fabian Kuger , Julia Dierle , Horst Fischer , Marc Schumann , Francesco Toschi

Liquid xenon offers several features, which make it suitable for applications in nuclear medicine, such as high scintillation yield and fast scintillation decay time. Moreover, being a continuous medium with a uniform response, liquid xenon…

Instrumentation and Detectors · Physics 2021-03-02 Carmen Romo-Luque

Liquid argon is used as a target material in several current and planned experiments related to dark matter direct searching and neutrino detection. SiPM is becoming the standard for scintillator detectors because of its advantages over…

Instrumentation and Detectors · Physics 2023-01-03 L. Wang , Y. Lei , T. A. Wang , C. Guo , K. K. Zhao , X. H. Liang , S. B. Wang , Y. D. Chen

Discrimination between electron and nuclear recoil events in a liquid argon scintillation detector has been demonstrated with simulations by using the differences in the scintillation photon time distribution between these classes of…

Astrophysics · Physics 2007-05-23 M. G. Boulay , A. Hime

Bi-directional reflection spectroscopy based on multiple scattering of particulate surfaces is employed in identifying the optical properties of titanium-iron oxide mineral from laboratory reflection measurements.However, the approach…

Optics · Physics 2024-11-28 Jingjing Chen , Xiaobo Yin

We performed a time-resolved spectroscopic study of the VUV/UV argon scintillation as a function of pressure and electric field, by means of a wavelength sensitive detector operated with different radioactive sources. Our work conveys new…

To separate scintillation and Cherenkov lights in water-based liquid scintillator detectors is a desired feature for future neutrino and proton decay researches. Linear alkyl benzene (LAB) is one important ingredient of a water-based liquid…

Instrumentation and Detectors · Physics 2016-06-14 Mohan Li , Ziyi Guo , Minfang Yeh , Zhe Wang , Shaomin Chen

We provide a new way of constraining the relative scintillation efficiency L_eff for liquid xenon. Using a simple estimate for the electronic and nuclear stopping powers together with an analysis of recombination processes we predict both…

Instrumentation and Methods for Astrophysics · Physics 2011-08-23 Fedor Bezrukov , Felix Kahlhoefer , Manfred Lindner

Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter and are expected to produce nuclear recoil (NR) events within liquid xenon time-projection chambers. We present a measurement of the scintillation timing…

A large number of particle detectors employ liquid argon as their target material owing to its high scintillation yield and its ability to drift ionization charge over large distances. Scintillation light from argon is peaked at 128 nm and…

The midsize single-phase liquid argon prototype detector, operating at the surface laboratory, is designed to measure scintillation light emitted by the liquid argon (LAr). The detector employs 42 8-inch photomultiplier tubes (PMT) to…

Instrumentation and Detectors · Physics 2023-08-22 K. K. Zhao , M. Y. Guan , J. C. Liu , C. G. Yang , S. T. Lin

We report the scintillation spectra of Ar-CF$_4$ mixtures in the range 210-800~nm, obtained under X-ray irradiation for various pressures (1-5~bar) and concentrations (0-100%). Special care was taken to eliminate effects related to space…

Instrumentation and Detectors · Physics 2023-09-06 P. Amedo , D. González-Díaz , F. M. Brunbauer , D. J. Fernández-Posada , E. Oliveri , L. Ropelewski

Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two…

Scintillation light generated as charged particles traverse large liquid argon detectors adds valuable information to studies of weakly-interacting particles. This paper uses both laboratory measurements and cosmic ray data from the Blanche…

Instrumentation and Detectors · Physics 2018-07-05 B. Howard , S. Mufson , D. Whittington , B. Adams , B. Baugh , J. R. Jordan , J. Karty , C. T. Macias , A. Pla-Dalmau

A strong anti-correlation between ionization and scintillation signals produced by MeV gamma-rays in liquid xenon has been measured and used to improve the energy resolution by combining the two signals. The improvement is explained by…

Astrophysics · Physics 2007-07-30 E. Aprile , K. L. Giboni , P. Majewski , K. Ni , M. Yamashita

Liquid xenon and liquid argon detectors are leading the direct dark matter search and are expected to be the candidate technology for the forthcoming generation of ultra-sensitive large-mass detectors. At present, the scintillation light…

High Energy Physics - Experiment · Physics 2022-09-20 Alessandro Razeto , Nicola Rossi

The fast scintillation decay time and the high scintillation yield of liquid xenon makes it an appropriate material for nuclear medicine. Moreover, being a continuous medium with a uniform response, liquid xenon allows one to avoid most of…

Particle detectors that use liquid xenon (LXe) as detection medium are among the leading technologies in the search for dark matter weakly interacting massive particles (WIMPs). A key enabling element has been the low-energy detection…

‹ Prev 1 3 4 5 6 7 10 Next ›