English
Related papers

Related papers: Stability of a trapped atom clock on a chip

200 papers

In trapped-atom clocks, the primary source of decoherence is often the phase noise of the oscillator. For this case, we derive theoretical performance gains by combining several atomic ensembles. For example, M ensembles of N atoms can be…

Quantum Physics · Physics 2013-11-15 T. Rosenband , D. R. Leibrandt

We experimentally investigate an optical clock based on $^{171}$Yb ($I=1/2$) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a…

Improvements in atom-light coherence are foundational to progress in quantum information science, quantum optics, and precision metrology. Optical atomic clocks require local oscillators with exceptional optical coherence due to the…

We consider optimization of a rubidium atom clock that uses magnetically trapped Bose condensed atoms in a highly elongated trap, and determine the optimal conditions for minimum Allan variance of the clock using microwave Ramsey fringe…

Atomic Physics · Physics 2009-09-29 D. Kadio , Y. B. Band

The exquisite control exhibited over quantum states of individual particles has revolutionized the field of precision measurement, as exemplified by the most accurate atomic clock realized in single trapped ions. Whereas many-atom lattice…

We report the coherent manipulation of internal states of neutral atoms in a magnetic microchip trap. Coherence lifetimes exceeding 1 s are observed with atoms at distances of $5-130 \mu$m from the microchip surface. The coherence lifetime…

Quantum Physics · Physics 2009-11-10 Philipp Treutlein , Peter Hommelhoff , Tilo Steinmetz , Theodor W. Hänsch , Jakob Reichel

This paper describes advances in microwave frequency standards using laser-cooled atoms at BNM-SYRTE. First, recent improvements of the $^{133}$Cs and $^{87}$Rb atomic fountains are described. Thanks to the routine use of a cryogenic…

Time and frequency are the most accurately measurable quantities, providing foundations for science and modern technologies. The accuracy relies on the SI (Syst\'eme International) second that refers to Cs microwave clocks with fractional…

Atomic Physics · Physics 2014-05-19 Ichiro Ushijima , Masao Takamoto , Manoj Das , Takuya Ohkubo , Hidetoshi Katori

Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been…

The stability of an optical atomic clock is a critical figure of merit for almost all clock applications. To this end, much optical atomic clock research has focused on reducing clock instability by increasing the atom number, lengthening…

Atomic Physics · Physics 2023-12-21 Xin Zheng , Jonathan Dolde , Shimon Kolkowitz

The mid-term fractional frequency stability of miniaturized atomic clocks can be limited by light-shift effects. In this Letter, we demonstrate the implementation of a symmetric Auto-Balanced Ramsey (SABR) interrogation sequence in a…

Atomic Physics · Physics 2022-02-23 M. Abdel Hafiz , C. Carlé , N. Passilly , J. M. Danet , C. E. Calosso , R. Boudot

We perform Ramsey spectroscopy on the ground state of ultra-cold 87Rb atoms magnetically trapped on a chip in the Knudsen regime. Field inhomogeneities over the sample should limit the 1/e contrast decay time to about 3 s, while decay times…

In the last ten years extraordinary results in time and frequency metrology have been demonstrated. Frequency-stabilization techniques for continuous-wave lasers and femto-second optical frequency combs have enabled a rapid development of…

Atomic Physics · Physics 2014-01-14 N. Poli , C. W. Oates , P. Gill , G. M. Tino

Transition frequencies of atoms and ions are among the most accurately accessible quantities in nature, playing important roles in pushing the frontiers of science by testing fundamental laws of physics, in addition to a wide range of…

The absolute frequency of the 1S0-3P0 clock transition of 87Sr has been measured to be 429 228 004 229 873.65 (37) Hz using lattice-confined atoms, where the fractional uncertainty of 8.6x10-16 represents one of the most accurate…

We report on the performance of the first table-top prototype atomic clock based on coherent population trapping (CPT) resonances with parallel linearly polarized optical fields (lin||lin configuration). Our apparatus uses a vertical cavity…

Atomic Physics · Physics 2010-09-29 Eugeniy E. Mikhailov , Travis Horrom , Nathan Belcher , Irina Novikova

Microelectromechanical (MEMS) resonators are widely used in timekeeping applications, and recent advances in fabrication, materials, and encapsulation technology have advanced their potential as high stability frequency references. However,…

Aided by ultra-high resolution spectroscopy, the overall systematic uncertainty of the $^{1}S_{0}$-$^{3}P_{0}$ clock resonance for lattice-confined $^{87}$Sr has been characterized to $9\times10^{-16}$. This uncertainty is at a level…

We experimentally investigate an optical frequency standard based on the $^2S_{1/2} (F=0)\to {}^2F_{7/2} (F=3)$ electric octupole (\textit{E}3) transition of a single trapped $^{171}$Yb$^+$ ion. For the spectroscopy of this strongly…

Atomic and Molecular Clusters · Physics 2016-02-15 N. Huntemann , C. Sanner , B. Lipphardt , Chr. Tamm , E. Peik

For the past 15 years, tremendous progress within the fields of laser stabilization, optical frequency combs and atom cooling and trapping have allowed the realization of optical atomic clocks with unrivaled performances. These instruments…

Atomic Physics · Physics 2018-04-09 Marion Delehaye , Clément Lacroûte