New generation Cadmium Telluride (CZT & CdTe) solid state detectors can provide high quantum efficiency with reasonably good energy resolution and can operate at near room temperature; an unique advantage for space experiments. We present…

Astrophysics · Physics 2009-11-13 J. S. Yadav , S. Savitri , J. P. Malkar

We developed CdTe double-sided strip detectors (DSDs or cross strip detectors) and evaluated their spectral and imaging performance for hard X-rays and gamma-rays. Though the double-sided strip configuration is suitable for imagers with a…

Extensive simulations of a portable radiation detecting system have been performed in order to explore important performance parameters. The instrument consists of a stack of ten detecting layers made of pixelated Cadmium Telluride (CdTe)…

Instrumentation and Detectors · Physics 2011-01-21 K. Karafasoulis , K. Zachariadou , S. Seferlis , I. Kaissas , C. Lambropoulos , D. Loukas , C. Poritiriadis

Polarimetry is an area of high energy astrophysics which is still relatively unexplored, even though it is recognized that this type of measurement could drastically increase our knowledge of the physics and geometry of high energy sources.…

The energy range above 60 keV is important for the study of many open problems in high energy astrophysics such as the role of Inverse Compton with respect to synchrotron or thermal processes in GRBs, non thermal mechanisms in SNR, the…

We are developing a Compton telescope based on high resolution Si and CdTe imaging devices in order to obtain a high sensitivity astrophysical observation in sub-MeV gamma-ray region. In this paper, recent results from the prototype Si/CdTe…

The CALICE collaboration conducts calorimeter R&D for highly granular calorimeters, mainly for their application in detectors for a future lepton collider at the TeV scale. The activities ranges from generic R&D with small devices up to…

Instrumentation and Detectors · Physics 2013-03-12 The CALICE Collaboration

IDeF-X HD is a 32-channel analog front-end with self-triggering capability optimized for the readout of 16 x 16 pixels CdTe or CdZnTe pixelated detectors to build low power micro gamma camera. IDeF-X HD has been designed in the standard AMS…

Instrumentation and Methods for Astrophysics · Physics 2021-02-04 Olivier Gevin , Francis Lugiez , Alicja Michalowska , Aline Meuris , Olivier Limousin , Eric Delagnes , Olivier Lemaire , Frédéric Pinsard

The Belle II experiment, operating at the asymmetric SuperKEKB $e^+e^-$ collider, is preparing an upgrade of its vertex detector to cope with an increased luminosity of $6 \times 10^{35}$ cm$^{-2}$s$^{-1}$. The upgraded vertex detector…

Instrumentation and Detectors · Physics 2026-05-14 Belle II VTX Collaboration

The Caltech HIgh-speed Multi-color camERA (CHIMERA) is a new instrument that has been developed for use at the prime focus of the Hale 200-inch telescope. Simultaneous optical imaging in two bands is enabled by a dichroic beam splitter…

Instrumentation and Methods for Astrophysics · Physics 2024-05-24 Leon K. Harding , Gregg Hallinan , Jennifer Milburn , Paul Gardner , Nick Konidaris , Navtej Singh , Michael Shao , Jagmit Sandhu , Gillian Kyne , Hilke E. Schlichting

Spectroscopic measurements are presented using the PID350 pixelated gamma radiation detectors. A high-speed data acquisition system has been developed in order to reduce the data loss during the data reading in case of a high flux of…

Instrumentation and Detectors · Physics 2010-11-16 K. Karafasoulis , K. Zachariadou , S. Seferlis , I. Papadakis , D. Loukas , C. Lambropoulos , C. Potiriadis

We have been developing a semiconductor Compton telescope to explore the universe in the energy band from several tens of keV to a few MeV. We use a Si strip and CdTe pixel detector for the Compton telescope to cover an energy range from 60…

We developed a 2-mm-thick CdTe double-sided strip detector (CdTe-DSD) with a 250 um strip pitch, which has high spatial resolution with a uniform large imaging area of 10 cm$^2$ and high energy resolution with high detection efficiency in…

Instrumentation and Methods for Astrophysics · Physics 2023-12-19 Takahiro Minami , Miho Katsuragawa , Shunsaku Nagasawa , Shin'ichiro Takeda , Shin Watanabe , Yutaka Tsuzuki , Tadayuki Takahashi

A simplified digital spectrometer for the study of $\gamma$-rays with energies up to $\sim100$ MeV is presented and tested. The spectrometer is only consisted of a fast digital oscilloscope and three scintillation detectors which can work…

Instrumentation and Detectors · Physics 2015-12-09 S. S. Markochev , N. V. Eremin

The gamma-ray energy range from a few hundred keV to a few hundred MeV has remained largely unexplored, mainly due to the challenging nature of the measurements, since the pi- oneering, but limited, observations by COMPTEL on the Compton…

We report on several versions of the calibration and monitoring system dedicated to scintillator tile calorimeters built within the CALICE collaboration and intended for future linear collider experiments. Whereas the first, a 1 m3 analogue…

Instrumentation and Detectors · Physics 2019-08-15 Jaroslav Zalesak

The SST-1M is a 4-m diameter mirror Davies-Cotton gamma-ray telescope. It has been designed to cover the energy range above 500 GeV and to be part of an array of telescopes separated by 150-200 m. Its innovative camera is featuring large…

We report spectral and imaging performance of a pixelated CdZnTe detector custom designed for the \emph{MeVCube} project: a small Compton telescope on a CubeSat platform. \emph{MeVCube} is expected to cover the energy range between…

Instrumentation and Methods for Astrophysics · Physics 2022-08-10 Giulio Lucchetta , Markus Ackermann , David Berge , Ingo Bloch , Rolf Bühler , Hermann Kolanoski , Wolfgang Lange , Francesco Zappon

The CALICE collaboration is developing an engineering prototype of an analog hadron calorimeter for a future linear collider detector. The prototype has to prove the feasibility of building a realistic detector with fully integrated…

Instrumentation and Detectors · Physics 2019-08-13 Oskar Hartbrich , Mark Terwort

CdTe is the most commercially successful thin-film photovoltaic technology to date. The recent development of Se-alloyed CdSe$_{x}$Te$_{1-x}$ layers in CdTe solar cells has led to higher device efficiencies, due to a lowered bandgap…

Materials Science · Physics 2023-10-11 Alan R Bowman , Jacob J Leaver , Kyle Frohna , Samuel D Stranks , Giulia Tagliabue , Jon D Major