Related papers: Single-pixel ghost microscopy based on compressed …
Schlieren deflectometry aims at characterizing the deflections undergone by refracted incident light rays at any surface point of a transparent object. For smooth surfaces, each surface location is actually associated with a sparse…
Imaging for an occluded object is usually a difficult problem, in this letter, we introduce an imaging scheme based on computational ghost imaging, which can obtain the image of a target object behind an obstacle. According to our…
In recent times, spatial light modulators have become a common tool in optics laboratories as well as industrial environment to shape the spatial structure of a beam. Although these devices are often easy to use, they usually come at a high…
The information lost in images of undersampled CCD cameras can be recovered with the technique of `dithering'. A number of subexposures is taken with sub-pixel shifts in order to record structures on scales smaller than a pixel. The…
Popular methods in compressed sensing (CS) are dependent on deep learning (DL), where large amounts of data are used to train non-linear reconstruction models. However, ensuring generalisability over and access to multiple datasets is…
We demonstrate a wavefront sensor based on the compressive sensing, single-pixel camera. Using a high-resolution spatial light modulator (SLM) as a variable waveplate, we weakly couple an optical field's transverse-position and polarization…
Demonstrating the utility of quantum algorithms is a long-standing challenge, where quantum machine learning becomes one of the most promising candidate that can be resorted to. In this study, we investigate a quantum neural compressive…
In this paper, we present a method for speckle pattern design using deep learning. The speckle patterns possess unique features after experiencing convolutions in Speckle-Net, our well-designed framework for speckle pattern generation. We…
Since the invention of digital cameras there has been a concerted drive towards detector arrays with higher spatial resolution. Microscanning is a technique that provides a final higher resolution image by combining multiple images of a…
We present a compressive sensing protocol that tracks a moving object by removing static components from a scene. The implementation is carried out on a ghost imaging scheme to minimize both the number of photons and the number of…
Computational ghost imaging (CGI) and single-pixel camera (SPC) are two types of single-pixel imaging and attracts increasing interest in recent years. The performance differences of CGI and SPC in difference light disturbance environment…
In absence of a lens to form an image, incoherent or partially coherent light scattering off an obstructive or reflective object forms a broad intensity distribution in the far field with only feeble spatial features. We show here that…
We demonstrate experimentally ghost optical coherence tomography using a broadband incoherent supercontinuum light source with shot-to-shot random spectral fluctuations. The technique is based on ghost imaging in the spectral domain where…
Ghost imaging is usually based on optoelectronic process and eletronic computing. We here propose a new ghost imaging scheme, which avoids any optoelectronic or electronic process. Instead, the proposed scheme exploits all-optical…
A new line of research uses compression methods to measure the similarity between signals. Two signals are considered similar if one can be compressed significantly when the information of the other is known. The existing compression-based…
Over the past decade, reflection matrix microscopy (RMM) and advanced image reconstruction algorithms have emerged to address the fundamental imaging depth limitations of optical microscopy in thick biological tissues and complex media. In…
Single-shot fluorescence imaging techniques have gained increasing interest in recent years due to their ability to rapidly capture complex biological data without the need for extensive scanning. In this letter, we introduce polarized…
The usually reported pixel resolution of single pixel imaging (SPI) varies between $32 \times 32$ and $256 \times 256$ pixels falling far below imaging standards with classical methods. Low resolution results from the trade-off between the…
Image simulation remains under-exploited for the most widely used biological phase microscopy methods, because of difficulties in simulating partially coherent illumination. We describe an open-source toolbox, microlith…
The image information acquisition ability of a conventional camera is usually much lower than the Shannon Limit since it does not make use of the correlation between pixels of image data. Applying a random phase modulator to code the…