English
Related papers

Related papers: A Global Analysis of Light and Charge Yields in Li…

200 papers

We have performed measurements of scintillation light in liquid neon, observing a signal yield in our detector as high as (3.5 $\pm$ 0.4) photoelectrons/keV. We measure pulse shape discrimination efficiency between electronic and nuclear…

Nuclear Experiment · Physics 2012-08-14 W. H. Lippincott , K. J. Coakley , D. Gastler , E. Kearns , D. N. McKinsey , J. A. Nikkel

We extend the study of the performance of a prototype two-phase liquid xenon WIMP dark matter detector to recoil energies below 20 keV. We demonstrate a new method for obtaining the best estimate of the energies of events using a calibrated…

Astrophysics · Physics 2008-11-26 T. Shutt , C. E. Dahl , J. Kwong , A. Bolozdynya , P. Brusov

The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid xenon was…

Instrumentation and Detectors · Physics 2016-10-27 LUX Collaboration , D. S. Akerib , S. Alsum , H. M. Araújo , X. Bai , A. J. Bailey , J. Balajthy , P. Beltrame , E. P. Bernard , A. Bernstein , T. P. Biesiadzinski , E. M. Boulton , A. Bradley , R. Bramante , P. Brás , D. Byram , S. B. Cahn , M. C. Carmona-Benitez , C. Chan , J. J. Chapman , A. A. Chiller , C. Chiller , A. Currie , J. E. Cutter , T. J. R. Davison , L. de Viveiros , A. Dobi , J. E. Y. Dobson , E. Druszkiewicz , B. N. Edwards , C. H. Faham , S. Fiorucci , R. J. Gaitskell , V. M. Gehman , C. Ghag , K. R. Gibson , M. G. D. Gilchriese , C. R. Hall , M. Hanhardt , S. J. Haselschwardt , S. A. Hertel , D. P. Hogan , M. Horn , D. Q. Huang , C. M. Ignarra , M. Ihm , R. G. Jacobsen , W. Ji , K. Kamdin , K. Kazkaz , D. Khaitan , R. Knoche , N. A. Larsen , C. Lee , B. G. Lenardo , K. T. Lesko , A. Lindote , M. I. Lopes , D. C. Malling , A. Manalaysay , R. L. Mannino , M. F. Marzioni , D. N. McKinsey , D. M. Mei , J. Mock , M. Moongweluwan , J. A. Morad , A. St. J. Murphy , C. Nehrkorn , H. N. Nelson , F. Neves , K. O'Sullivan , K. C. Oliver-Mallory , K. J. Palladino , M. Pangilinan , E. K. Pease , P. Phelps , L. Reichhart , C. A. Rhyne , S. Shaw , T. A. Shutt , C. Silva , M. Solmaz , V. N. Solovov , P. Sorensen , S. Stephenson , T. J. Sumner , M. Szydagis , D. J. Taylor , W. C. Taylor , B. P. Tennyson , P. A. Terman , D. R. Tiedt , W. H. To , M. Tripathi , L. Tvrznikova , S. Uvarov , J. R. Verbus , R. C. Webb , J. T. White , T. J. Whitis , M. S. Witherell , F. L. H. Wolfs , J. Xu , K. Yazdani , S. K. Young , C. Zhang

Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by $\gamma$ interactions from…

Knowledge of the ionization and scintillation responses of liquid xenon (LXe) to nuclear recoils is crucial for LXe-based dark matter experiments. Current calibrations carry large uncertainties in the low-energy region below $\sim3$…

Liquid xenon is an important detection medium in direct dark matter experiments, which search for low-energy nuclear recoils produced by the elastic scattering of WIMPs with quarks. The two existing measurements of the relative…

The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron…

Instrumentation and Detectors · Physics 2022-10-20 C. S. Amarasinghe , R. Coronel , D. Q. Huang , Y. Liu , M. Arthurs , S. Steinfeld , R. Gaitskell , W. Lorenzon

The response of liquid xenon to low-energy electronic recoils is relevant in the search for dark-matter candidates which interact predominantly with atomic electrons in the medium, such as axions or axion-like particles, as opposed to…

Instrumentation and Methods for Astrophysics · Physics 2013-06-21 Laura Baudis , Hrvoje Dujmovic , Christopher Geis , Andreas James , Alexander Kish , Aaron Manalaysay , Teresa Marrodan Undagoitia , Marc Schumann

The Migdal effect predicts that a nuclear recoil interaction can be accompanied by atomic ionization, allowing many dark matter direct detection experiments to gain sensitivity to sub-GeV masses. We report the first direct search for the…

Liquid xenon (LXe) particle detectors are a powerful technology in the field of dark matter direct detection, having shown impressive results in recent years and holding strong possibility for leading the field in sensitivity to galactic…

Instrumentation and Methods for Astrophysics · Physics 2010-07-23 A. Manalaysay

Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for…

Instrumentation and Detectors · Physics 2022-11-24 SuperCDMS Collaboration , M. F. Albakry , I. Alkhatib , D. W. P. Amaral , T. Aralis , T. Aramaki , I. J. Arnquist , I. Ataee Langroudy , E. Azadbakht , S. Banik , C. Bathurst , D. A. Bauer , L. V. S. Bezerra , R. Bhattacharyya , M. A. Bowles , P. L. Brink , R. Bunker , B. Cabrera , R. Calkins , R. A. Cameron , C. Cartaro , D. G. Cerdeño , Y. -Y. Chang , M. Chaudhuri , R. Chen , N. Chott , J. Cooley , H. Coombes , J. Corbett , P. Cushman , F. De Brienne , M. L. di Vacri , M. D. Diamond , E. Fascione , E. Figueroa-Feliciano , C. W. Fink , K. Fouts , M. Fritts , G. Gerbier , R. Germond , M. Ghaith , S. R. Golwala , J. Hall , B. A. Hines , M. I. Hollister , Z. Hong , E. W. Hoppe , L. Hsu , M. E. Huber , V. Iyer , A. Jastram , V. K. S. Kashyap , M. H. Kelsey , A. Kubik , N. A. Kurinsky , R. E. Lawrence , M. Lee , A. Li , J. Liu , Y. Liu , B. Loer , P. Lukens , D. MacDonell , D. B. MacFarlane , R. Mahapatra , V. Mandic , N. Mast , A. J. Mayer , H. Meyer zu Theenhausen , É. Michaud , E. Michielin , N. Mirabolfathi , B. Mohanty , J. D. Morales Mendoza , S. Nagorny , J. Nelson , H. Neog , V. Novati , J. L. Orrell , M. D. Osborne , S. M. Oser , W. A. Page , R. Partridge , D. S. Pedreros , R. Podviianiuk , F. Ponce , S. Poudel , A. Pradeep , M. Pyle , W. Rau , E. Reid , R. Ren , T. Reynolds , A. Roberts , A. E. Robinson , T. Saab , B. Sadoulet , I. Saikia , J. Sander , A. Sattari , A. Scarff , B. Schmidt , R. W. Schnee , S. Scorza , B. Serfass , D. J. Sincavage , C. Stanford , J. Street , F. K. Thasrawala , D. Toback , R. Underwood , S. Verma , A. N. Villano , B. von Krosigk , S. L. Watkins , O. Wen , Z. Williams , M. J. Wilson , J. Winchell , K. Wykoff , S. Yellin , B. A. Young , T. C. Yu , B. Zatschler , S. Zatschler , A. Zaytsev , E. Zhang , L. Zheng , S. Zuber

Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability to low-mass dark matter interactions, we investigated the…

Taking liquid xenon detectors as a case study, the importance of a robust recoil energy calibration as a prerequisite to a search for light-mass Weakly Interacting Massive Particles (WIMPs) is emphasized. Important shortfalls in the…

Instrumentation and Methods for Astrophysics · Physics 2010-10-27 J. I. Collar

We report here methods and techniques for creating and improving a model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time-projection chamber. Starting with the recent release of the…

We present a comprehensive analysis of electronic recoil vs. nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 2014-16 runs of the Large Underground Xenon (LUX) experiment.…

Liquid Xenon (LXe) is an excellent material for experiments designed to detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs). A low energy detection threshold is essential for a sensitive WIMP search. The…

Instrumentation and Detectors · Physics 2010-04-06 A. Manzur , A. Curioni , L. Kastens , D. N. McKinsey , K. Ni , T. Wongjirad

The energy calibration of nuclear recoil detectors is of primary importance to rare-event experiments such as those of direct dark matter search and coherent neutrino-nucleus scattering. In particular, such a calibration is performed by…

Instrumentation and Detectors · Physics 2014-10-06 A. Bondar , A. Buzulutskov , A. Dolgov , E. Grishnyaev , S. Polosatkin , L. Shekhtman , E. Shemyakina , A. Sokolov

We present the results of the first experimental study of ionization yield of electron recoils with energies below 100 keV produced in liquid xenon by the isotopes: 37Ar, 83mKr, 241Am, 129Xe, 131Xe. It is confirmed by a direct measurement…

Nuclear recoil ionization yield constitutes a critical uncertainty source in low-energy detection for dark matter (DM) and coherent elastic neutrino-nucleus scattering (CE$\nu$NS) experiments. We present a novel methodology employing…

Instrumentation and Detectors · Physics 2026-03-18 Chang-Hao Fang