Related papers: Dry dilution refrigerator with 4He-1K-loop
Here we report the performance of a small scale 4 K pulse tube cryocooler operating with a low input power reaching a minimum temperature of 2.2 K, as well as a cooling capacity of over 240 mW at 4.2 K. The compressor is air cooled and can…
With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems capable of operation at cryogenic temperatures in order to…
A robust cryogenic infrastructure in form of a wired, thermally optimized dilution refrigerator is essential for present and future solid-state based quantum processors. Here, we engineer an extensible cryogenic setup, which minimizes…
We have designed and built a scanning tunneling microscope (STM) setup for operation at millikelvin temperatures in ultra high vacuum. A compact cryostat with an integrated dilution refrigerator has been built, that allows measurements at a…
Refrigeration is an important enabler for quantum technology. The very low energy of the fundamental excitations typically utilized in quantum technology devices and systems requires temperature well below 1 K. Expensive cryostats are…
We present a parallel network of 16 demagnetization refrigerators mounted on a cryofree dilution refrigerator aimed to cool nanoelectronic devices to sub-millikelvin temperatures. To measure the refrigerator temperature, the thermal motion…
The external shell of the CUORE cryostat is a large cryogen-free system designed to host the dilution refrigerator and the bolometers of the CUORE experiment in a low radioactivity environment. The three vessels that form the outer shell…
A superconductor with a gap in the density of states or a quantum dot with discrete energy levels is a central building block in realizing an electronic on-chip cooler. They can work as energy filters, allowing only hot quasiparticles to…
We present the design and implementation of a mechanical low-pass filter vibration isolation used to reduce the vibrational noise in a cryogen-free dilution refrigerator operated at 10 mK, intended for scanning probe techniques. We discuss…
We describe a helium evaporation refrigerator used to cool dynamically polarized proton and deuteron targets for electron-scattering experiments using the CEBAF Large Acceptance Spectrometer CLAS12 at Jefferson Lab. The geometry of the…
One of the daunting challenges in modern low temperature scanning tunneling microscopy (STM) is the difficulty of combining atomic resolution with cryogen free cooling. Further functionality needs, such as ultra-high vacuum (UHV), high…
Advances in cryogenic electron microscopy have opened new avenues for probing quantum phenomena in correlated materials. This study reports the installation and performance of a new side-entry condenZero cryogenic cooling system for JEOL…
A Kelvinox 400 dilution refrigerator with the ability to load samples onto the mixing chamber from the bottom of the cryostat has been combined with an ultrahigh-vacuum (UHV) deposition chamber equipped with molecular beam sources. The…
A design and implementation of "in-cell" magnetic refrigeration to achieve sub-10 mK temperatures T in cryogen-free dilution refrigerators is presented. The ultra low temperatures below 5 mK are attained in finite magnetic fields B up to 1…
We present a study of phase separation from supersaturated 3He-4He liquid mixtures at low temperatures addressing both the degree of critical supersaturation Dx and the thermal-to-quantum crossover temperature T* for the nucleation process.…
A cryogen-free cryostat cooled by a closed cycle cryocooler is compact, can provide uninterrupted long-term operation (up to ten thousand hours) and is suited to temperatures from 3 K to 300 K. Its intrinsic temperature oscillation,…
Many laboratories routinely cool samples to 10 mK, but relatively few can cool condensed matter below 1 mK. Easy access to the microkelvin range would propel fields such as quantum sensors and quantum materials. Such temperatures are…
We developed a cryogenic system on a rotating table that achieves sub-Kelvin conditions. The cryogenic system consists of a helium sorption cooler and a pulse tube cooler in a cryostat mounted on a rotating table. Two rotary-joint…
We describe a device to conveniently measure the positions of the phase boundaries in a dilution refrigerator. We show how a simple modification of a standard capacitive level gauge (segmentation of one of the electrodes) permits a direct…
A cryogen-free cryostat cooled using a 4 K commercial GM or pulse tube cryocooler (PTC) displays temperature oscillations caused by the intrinsic working principle of the regenerative cryocooler. To dampen such oscillations usually requires…