Related papers: Orthogonal Matrix Retrieval in Cryo-Electron Micro…
Single-particle reconstruction in cryo-electron microscopy (cryo-EM) is an increasingly popular technique for determining the 3-D structure of a molecule from several noisy 2-D projections images taken at unknown viewing angles. Most…
Cryo-electron microscopy (cryo-EM) is a powerful imaging technique for reconstructing three-dimensional molecular structures from noisy tomographic projection images of randomly oriented particles. We introduce a new data fusion framework,…
Single-particle cryo-electron microscopy (cryo-EM) is an emerging imaging modality capable of visualizing proteins and macro-molecular complexes at near-atomic resolution. The low electron-doses used to prevent sample radiation damage,…
Phase retrieval refers to algorithmic methods for recovering a signal from its phaseless measurements. Local search algorithms that work directly on the non-convex formulation of the problem have been very popular recently. Due to the…
A common task in cryo-electron microscopy (cryo-EM) data processing is to compare three-dimensional density maps of macromolecules. In this paper, we propose an algorithm for aligning three-dimensional density maps that exploits common…
Due to the extremely low signal-to-noise ratio (SNR) and unknown poses (projection angles and image shifts) in cryo-electron microscopy (cryo-EM) experiments, reconstructing 3D volumes from 2D images is very challenging. In addition to…
Cryo-electron microscopy (cryo-EM) has emerged as a powerful technique for resolving the three-dimensional structures of macromolecules. A key challenge in cryo-EM is characterizing continuous heterogeneity, where molecules adopt a…
We presented a new 3D refinement method for Cryo-EM single particle analysis which can improve the resolution of final electron density map in this paper. We proposed to enforce both sparsity and smoothness to improve the regularity of…
Cryogenic electron microscopy (cryo-EM) has become an enabling technology in drug discovery and in understanding molecular bases of disease by producing near-atomic resolution (less than 0.4 nm) 3D reconstructions of biological…
Direct detector device (DDD) cameras have revolutionized single particle electron cryomicroscopy (cryo-EM). In addition to an improved camera detective quantum efficiency, acquisition of DDD movies allows for correction of movement of the…
Cryo-EM is a vital technique for determining 3D structure of biological molecules such as proteins and viruses. The cryo-EM reconstruction problem is challenging due to the high noise levels, the missing poses of particles, and the…
Motivated by a certain molecular reconstruction methodology in cryo-electron microscopy, we consider the problem of solving a linear system with two unknown orthogonal matrices, which is a generalization of the well-known orthogonal…
We show that de-focused single particle images recorded using a cryo-electron microscope (cryoEM) system may be processed like a Fresnel zone in-line hologram to obtain physically meaningful quantitative phase maps associated with…
Cryo-electron microscopy (cryo-EM) has recently become a premier method for obtaining high-resolution structures of biological macromolecules. However, it is limited to biomolecular samples with low conformational heterogeneity, where all…
Traditional sampling schemes often assume that the sampling locations are known. Motivated by the recent bioimaging technique known as cryogenic electron microscopy (cryoEM), we consider the problem of reconstructing an unknown 3D structure…
The central problem in cryo-electron microscopy (cryo-EM) is to recover the 3D structure from noisy 2D projection images which requires estimating the missing projection angles (poses). Recent methods attempted to solve the 3D…
Cryo-Electron Microscopy (cryo-EM) has become an extremely powerful method for resolving structural details of large biomolecular complexes. However, challenging problems in single-particle methods remain open because of (1) the low…
In this report we study the problem of determining three-dimensional orientations for noisy projections of randomly oriented identical particles. The problem is of central importance in the tomographic reconstruction of the density map of…
Single-particle cryo-EM has transformed structural biology but still faces challenges in resolving conformational heterogeneity at atomic resolution. Existing cryo-EM heterogeneity analysis methods either lack atomic details or tend to…
A practical method utilising three-dimensional image pattern matching is proposed which, in principle, is capable of unambiguous determination of the types and positions of atoms in small molecules from defocus series collected at only a…