The Speedster-EXD is a new 64x64 pixel, 40 $\mu$m pixel pitch, 100 $\mu$m depletion depth hybrid CMOS X-ray detector (HCD) with the capability of reading out only those pixels containing event charge, thus enabling fast effective frame…

Instrumentation and Methods for Astrophysics · Physics 2016-02-26 Christopher V. Griffith , Abraham D. Falcone , Zachary R. Prieskorn , David N. Burrows

Future x-ray observatories will require imaging detectors with fast readout speeds that simultaneously achieve or exceed the other high performance parameters of x-ray charge-coupled devices (CCDs) used in many missions over the past three…

The Penn State X-ray detector lab, in collaboration with Teledyne Imaging Sensors (TIS), have progressed their efforts to improve soft X-ray Hybrid CMOS detector (HCD) technology on multiple fronts. Having newly acquired a Teledyne…

Instrumentation and Methods for Astrophysics · Physics 2018-10-16 Samuel V. Hull , Abraham D. Falcone , David N. Burrows , Mitchell Wages , Tanmoy Chattopadhyay , Maria McQuaide , Evan Bray , Matthew Kern

X-ray Hybrid CMOS Detectors (HCDs) have advantages over X-ray CCDs due to their higher readout rate abilities, flexible readout, inherent radiation hardness, and low power, which make them more suitable for the next generation large area…

X-ray hybrid CMOS detectors (HCDs) are a promising candidate for future x-ray missions requiring high throughput and fine angular resolution along with large field-of-view, such as the high-definition x-ray imager (HDXI) instrument on the…

Instrumentation and Methods for Astrophysics · Physics 2019-06-24 Samuel V. Hull , Abraham D. Falcone , Evan Bray , Mitchell Wages , Maria McQuaide , David N. Burrows

The development of Hybrid CMOS Detectors (HCDs) for X-Ray telescope focal planes will place them in con- tention with CCDs on future satellite missions due to their faster frame rates, flexible readout scenarios, lower power consumption,…

Instrumentation and Methods for Astrophysics · Physics 2015-05-14 Stephen D. Bongiorno , Abe D. Falcone , David N. Burrows , Robert Cook , Yibin Bai , Mark Farris

Future space-based X-ray telescope missions are likely to have significantly increased demands on detector read out rates due to increased collection area, and there will be a desire to minimize radiation damage in the interests of…

Instrumentation and Methods for Astrophysics · Physics 2015-06-05 Abe D. Falcone , Zachary Prieskorn , Christopher Griffith , Stephen Bongiorno , David N. Burrows

Hybrid CMOS detectors (HCDs) have several excellent features as high-performance X-ray detectors, including rapid readout, deep-depletion silicon for high quantum efficiency, radiation hardness, and low power. Random telegraph noise (RTN)…

AXIS, a Probe mission concept now in a Phase A study, will provide transformative studies of high-energy astrophysical phenomena thanks to its high-resolution X-ray spectral imaging. These capabilities are enabled by improvements to the…

In recent years, the performance of Scientifc Complementary Metal Oxide Semiconductor (sCMOS) sensors has been improved signifcantly. Compared with CCD sensors, sCMOS sensors have various advantages, making them potentially better devices…

Instrumentation and Methods for Astrophysics · Physics 2022-10-05 Qinyu Wu , Zhenqing Jia , Wenxin Wang , Zhixing Ling , Chen Zhang , Shuangnan Zhang , Weimin Yuan

A hard x-ray, high-speed, high dynamic range scientific x-ray imager is described. The imager is based on the mixed-mode pixel array detector (MM-PAD) readout chip coupled to a 750 micron thick cadmium telluride (CdTe) sensor. The full…

Instrumentation and Detectors · Physics 2020-08-26 Hugh T. Philipp , Mark W. Tate , Katherine S. Shanks , Prafull Purohit , Sol M. Gruner

A hybrid pixel detector based on the concept of simultaneous charge integration and photon counting will be presented. The second generation of a counting and integrating X-ray prototype CMOS chip (CIX) has been operated with different…

Instrumentation and Detectors · Physics 2009-11-13 H. Krüger , J. Fink , E. Kraft , N. Wermes , P. Fischer , I. Peric , C. Herrmann , M. Overdick , W. Rütten

The broad energy response, low electronic read noise, and good energy resolution have made X-ray Charge-Coupled Devices (CCDs) an obvious choice for developing soft X-ray astronomical instruments over the last half century. They also come…

X-ray Charge Coupled Devices (CCDs) have been the workhorse for soft X-ray astronomical instruments for the past quarter century. They provide broad energy response, extremely low electronic read noise, and good energy resolution in soft…

AXIS is a Probe-class mission concept that will provide high-throughput, high-spatial-resolution X-ray spectral imaging, enabling transformative studies of high-energy astrophysical phenomena. To take advantage of the advanced optics and…

Current, state-of-the-art CCDs are close to being able to deliver all key performance figures for future strategic X-ray missions except for the required frame rates. Our Stanford group is seeking to close this technology gap through a…

Instrumentation and Methods for Astrophysics · Physics 2022-08-03 S. Herrmann , P. Orel , T. Chattopadhyay , R. G. Morris , G. Prigozhin , K. Donlon , R. Foster , M. Bautz , S. Allen , C. Leitz

I present a summary of the experience with CCD-based vertex detectors at the SLD experiment at SLAC, and discuss their advantages for use at a future high-energy e+e- collider. The extensive R+D programme to improve further the vertexing…

High Energy Physics - Experiment · Physics 2009-10-31 P. N. Burrows

The position accuracy of X-ray photons on a CCD detector is generally believed to be limited by the CCD pixel size. While this is true in general, the position accuracy for X-ray events which deposit charge in more than one pixel can be…

We report on a new photon-counting detector possessing unprecedented spatial resolution, moderate spectral resolution and high background-rejection capability for 0.1-100 keV X-rays. It consists of an X-ray charge-coupled device (CCD) and…

Astrophysics · Physics 2009-11-10 E. Miyata , K. Tamura

In order to fully exploit the physics potential of the future high energy e+ e- linear collider, a Vertex Tracker providing high resolution track reconstruction is required. Hybrid pixel sensors are an attractive technology due to their…

High Energy Physics - Experiment · Physics 2019-08-17 M. Caccia , S. Borghi , R. Campagnolo , M. Battaglia , W. Kucewicz , H. Palka , A. Zalewska , K. Domanski , J. Marczewski , D. Tomaszewski