English
Related papers

Related papers: Large Magnetic Shielding Factor Measured by Nonlin…

200 papers

Slow magnetic relaxation and two level fluctuations measurements under high current injection is performed in single-contacted ferromagnetic nanostructures. The magnetic configurations of the samples are described by two metastable states…

Mesoscale and Nanoscale Physics · Physics 2009-11-10 J. -E. Wegrowe

Shielding sensitive scientific and medical devices from the magnetic field environment is one of the promising applications of superconductors. Magnetic field concentration by superconducting magnetic lenses is the opposite phenomenon…

Computational Physics · Physics 2018-08-01 Leonid Prigozhin , Vladimir Sokolovsky

A new technique of nonlinear magneto-optical rotation with amplitude modulated light is developed. The technique is an alternative to its counterpart with frequency modulated light and can be applied to sensitive measurements of magnetic…

We use the technique of chopped nonlinear magneto-optic rotation (NMOR) in a room temperature $^{133}$Cs vapor cell to measure the permanent electric dipole moment (EDM) in the atom. The cell has paraffin coating on the walls to increase…

Atomic Physics · Physics 2016-11-08 Harish Ravi , Mangesh Bhattarai , Abhilash Y D , Ummal Momeen , Vasant Natarajan

High-permeability magnetic shields generate magnetic field noise that can limit the sensitivity of modern precision measurements. We show that calculations based on the fluctuation-dissipation theorem allow quantitative evaluation of…

Instrumentation and Detectors · Physics 2009-11-13 S. -K. Lee , M. V. Romalis

We propose a magnetometer for the precise measurement of AC magnetic fields that uses a Terbium-doped optical fiber with half-waveplates built into it at specified distances. Our scheme uses an open-loop quantum control technique called…

Quantum Physics · Physics 2018-07-25 Manish K. Gupta , Jonathan Kunjummen , Xiaoting Wang , Jonathan P. Dowling

This note presents measurements that support the conclusion that it is feasible to achieve magnetic field values at the level of 5 milliGauss for a cryomodule in a realistic and representative ambient magnetic field environment.

Accelerator Physics · Physics 2014-09-03 Anthony C. Crawford

We developed a new technique for measuring the thermodynamic entropy as a function of the magnetic field angle. This technique enables high-resolution angle-resolved measurements of the entropy in an unprecedentedly short measuring time.…

Strongly Correlated Electrons · Physics 2018-06-15 Shunichiro Kittaka , Shota Nakamura , Hiroaki Kadowaki , Hiroshi Takatsu , Toshiro Sakakibara

Measurements of the magnetic irreversibility line and time-logarithmic decay of the magnetization are described for three $Fe_{2}O_{3}$ samples composed of regular amorphous, acicular amorphous and crystalline nanoparticles. The relaxation…

Condensed Matter · Physics 2009-10-31 R. Prozorov , Y. Yeshurun , T. Prozorov , A. Gedanken

We present a method to measure the magnetic properties of monolayers and ultra-thin films of magnetic material. The method is based on low energy muon spin rotation and $\beta$-detected nuclear magnetic resonance measurements. A spin probe…

Mesoscale and Nanoscale Physics · Physics 2012-06-07 Z. Salman , S. J. Blundell

We implement magnetic resonance force microscopy (MRFM) in an experimental geometry, where the long axis of the cantilever is normal to both the external magnetic field and the RF microwire source. Measurements are made of the statistical…

Mesoscale and Nanoscale Physics · Physics 2015-03-19 Fei Xue , P. Peddibhotla , M. Montinaro , D. Weber , M. Poggio

We have studied the magnetoresistance in a high-mobility Si inversion layer down to low electron concentrations at which the longitudinal resistivity $\rho_{xx}$ has an activated temperature dependence. The angle of the magnetic field was…

Strongly Correlated Electrons · Physics 2009-11-11 Mitsuaki Ooya , Kiyohiko Toyama , Tohru Okamoto

The shielding of the nuclear magnetic moment by the bound electron in hydrogen-like ions is calculated ab initio with inclusion of relativistic, nuclear, and quantum electrodynamics (QED) effects. The QED correction is evaluated to all…

Atomic Physics · Physics 2015-05-28 V. A. Yerokhin , K. Pachucki , Z. Harman , C. H. Keitel

A new experiment to measure the muon g-2 factor is proposed. We suppose the sensitivity of this experiment to be about 0.03 ppm. The developed experiment can be performed on an ordinary storage ring with a noncontinuous field created by…

High Energy Physics - Experiment · Physics 2011-06-27 Alexander J. Silenko

In this work, we present a comprehensive and comparative analysis of two detection modalities, i.e., polarization rotation and absorption measurement of light, for a double resonance alignment based optical magnetometer (DRAM). We derive…

Optics · Physics 2024-03-11 A. Akbar , M. Kozbiál , L. Elson , A. Meraki , J. Kolodyński , K. Jensen

Three-dimensional topological insulators or axion insulators exhibit the topological magnetoelectric effect, which is isotropic with a universal coefficient of proportionality quantized in units of $e^2/2h$. Here we study the finite-size…

Mesoscale and Nanoscale Physics · Physics 2020-05-20 Zhaochen Liu , Jing Wang

A combination of analytical calculations and vectormagnetogram data are utilized to develop a non-axisymmetric non-force-free magnetic field and asses its viability in describing solar active regions. For the purpose, we construct a local…

Solar and Stellar Astrophysics · Physics 2016-11-21 A. Prasad , R. Bhattacharyya

Local magneto-optical imaging and global magnetization measurement techniques were used in order to visualize shielding effects in the superconducting core of MgB_2 wires sheathed by ferromagnetic iron (Fe). The magnetic shielding can…

Superconductivity · Physics 2007-05-23 Alexey V. Pan , Sihai Zhou , Shi Xue Dou , Hua Kun Liu

High-resolution magnetostriction measurement of $\Delta L/L\sim10^{-6}$ at a speed of 5 MHz is performed, using optical filter method as the detection scheme for the fiber Bragg grating (FBG) based strain monitor is performed under…

Materials Science · Physics 2018-09-11 Akihiko Ikeda , Yasuhiro H. Matsuda , Hiroshi Tsuda

A sensitive vector magnetometry with high spatial resolution is important for various practical applications, such as magnetocardiography, magnetoencephalography, explosive materials detection and many others. We propose a magnetometer…

Applied Physics · Physics 2021-07-07 D. O. Ignatyeva , G. A. Knyazev , A. N. Kalish , A. I. Chernov , V. I. Belotelov
‹ Prev 1 3 4 5 6 7 10 Next ›