Related papers: Improved Scatter Correction in X-Ray Cone Beam CT …
We study an inverse problem for the wave equation where localized wave sources in random scattering media are to be determined from time resolved measurements of the waves at an array of receivers. The sources are far from the array, so the…
Cone-beam CT (CBCT) is installed in the treatment room to facilitate online clinical applications, including image guidance in radiation and surgery. Half-fan and short-can are the commonly used modes in clinical applications to expand the…
The G230LB grating used with STIS's CCD detector scatters red light. In red objects, the scattered light mingles with the ultraviolet signal, causing spurious short-wavelength flux and weakening absorption features. Recent calibration…
Objective: Cone-beam computed tomography (CBCT) provides a low-dose imaging alternative to conventional CT, but suffers from noise, scatter, and artifacts that degrade image quality. Synthetic CT (sCT) aims to translate CBCT to high-quality…
Accurate camera pose estimation result is essential for visual SLAM (VSLAM). This paper presents a novel pose correction method to improve the accuracy of the VSLAM system. Firstly, the relationship between the camera pose estimation error…
For surgical planning and intra-operation imaging, CT reconstruction using X-ray images can potentially be an important alternative when CT imaging is not available or not feasible. In this paper, we aim to use biplanar X-rays to…
Cone beam computed tomography (CBCT) is an emerging medical imaging technique to visualize the internal anatomical structures of patients. During a CBCT scan, several projection images of different angles or views are collectively utilized…
Based on the stochastic maximum principle for the partially coupled forward-backward stochastic control system (FBSCS for short), a modified method of successive approximations (MSA for short) is established for stochastic recursive optimal…
In this paper we propose a modified cross correlation method to align images from the same class in single-particle electron microscopy of highly non-spherical structures. In this new method, First we coarsely align projection images, and…
Computational color constancy is a very important topic in computer vision and has attracted many researchers' attention. Recently, lots of research has shown the effects of high level visual content information for illumination estimation.…
Blur in X-ray radiographs not only reduces the sharpness of image edges but also reduces the overall contrast. The effective blur in a radiograph is the combined effect of blur from multiple sources such as the detector panel, X-ray source…
Since GRBs fade rapidly, it is important to publish accurate, precise positions at early times. For Swift-detected bursts, the best promptly available position is most commonly the X-ray Telescope (XRT) position. We present two processes,…
The undulator line of the Shanghai soft X-ray Free-electron Laser facility (SXFEL) has very tight tolerances on the straightness of the electron beam trajectory. However, the beam trajectory cannot meet the lasing requirements due to the…
Cone beam CT (CBCT) has been widely used for patient setup in image guided radiation therapy (IGRT). Radiation dose from CBCT scans has become a clinical concern. The purposes of this study are 1) to commission a GPU-based Monte Carlo (MC)…
This paper introduces a novel method for reconstructing cone beam computed tomography (CBCT) images for arbitrary orbits using a differentiable shift-variant filtered backprojection (FBP) neural network. Traditional CBCT reconstruction…
In coherent X-ray diffraction microscopy the diffraction pattern generated by a sample illuminated with coherent x-rays is recorded, and a computer algorithm recovers the unmeasured phases to synthesize an image. By avoiding the use of a…
We develop a new approach for estimating the risk of an arbitrary estimator of the mean vector in the classical normal means problem. The key idea is to generate two auxiliary data vectors, by adding carefully constructed normal noise…
Phase-contrast X-ray imaging can improve the visibility of weakly absorbing objects (e.g. soft tissues) by an order of magnitude or more compared to conventional radiographs. Previously, it has been shown that combining phase retrieval with…
An analytical approach describing properties of focused partially coherent X-ray beams is presented. The method is based on the results of statistical optics and gives both the beam size and transverse coherence length at any distance…
Accurate dose calculations in proton therapy rely on high-quality CT images. While planning CTs (pCTs) serve as a reference for dosimetric planning, Cone Beam CT (CBCT) is used throughout Adaptive Radiotherapy (ART) to generate sCTs for…