The LUX experiment has performed searches for dark matter particles scattering elastically on xenon nuclei, leading to stringent upper limits on the nuclear scattering cross sections for dark matter. Here, for results derived from…

Dual-phase xenon detectors are widely used in dark matter direct detection experiments, and have demonstrated the highest sensitivities to a variety of dark matter interactions. However, a key component of the dual-phase detector…

Instrumentation and Detectors · Physics 2019-06-05 Jingke Xu , Sergey Pereverzev , Brian Lenardo , James Kingston , Daniel Naim , Adam Bernstein , Kareem Kazkaz , Mani Tripathi

In the near future there will be the request for very large liquid Xenon (LXe) detectors for Dark Matter (DM) searches in the 50-ton range. To avoid an impractically long, single drift space of a dual-phase detector, it seems beneficial to…

Instrumentation and Detectors · Physics 2021-09-01 P. Juyal , K. L. Giboni , X. Ji , J. Liu

The XENON experiment aims at the direct detection of dark matter in the form of WIMPs (Weakly Interacting Massive Particles) via their elastic scattering off Xe nuclei. A fiducial mass of 1000 kg, distributed in ten independent liquid xenon…

We present an updated model of light and charge yields from nuclear recoils in liquid xenon with a simultaneously constrained parameter set. A global analysis is performed using measurements of electron and photon yields compiled from all…

Instrumentation and Methods for Astrophysics · Physics 2016-01-20 Brian Lenardo , Kareem Kazkaz , Aaron Manalaysay , Matthew Szydagis , Mani Tripathi

Ionization and scintillation produced by nuclear recoils in gaseous xenon at approximately 14 bar have been simultaneously observed in an electroluminescent time projection chamber. Neutrons from radioisotope $\alpha$-Be neutron sources…

A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting…

Instrumentation and Detectors · Physics 2018-01-23 nEXO Collaboration , M. Jewell , A. Schubert , W. R. Cen , J. Dalmasson , R. DeVoe , L. Fabris , G. Gratta , A. Jamil , G. Li , A. Odian , M. Patel , A. Pocar , D. Qiu , Q. Wang , L. J. Wen , J. B. Albert , G. Anton , I. J. Arnquist , I. Badhrees , P. Barbeau , D. Beck , V. Belov , F. Bourque , J. P. Brodsky , E. Brown , T. Brunner , A. Burenkov , G. F. Cao , L. Cao , C. Chambers , S. A. Charlebois , M. Chiu , B. Cleveland , M. Coon , A. Craycraft , W. Cree , M. Côté , T. Daniels , S. J. Daugherty , J. Daughhetee , S. Delaquis , A. Der Mesrobian-Kabakian , T. Didberidze , J. Dilling , Y. Y. Ding , M. J. Dolinski , A. Dragone , W. Fairbank , J. Farine , S. Feyzbakhsh , R. Fontaine , D. Fudenberg , G. Giacomini , R. Gornea , E. V. Hansen , D. Harris , M. Hasan , M. Heffner , E. W. Hoppe , A. House , P. Hufschmidt , M. Hughes , J. Hößl , Y. Ito , A. Iverson , X. S. Jiang , S. Johnston , A. Karelin , L. J. Kaufman , T. Koffas , S. Kravitz , R. Krücken , A. Kuchenkov , K. S. Kumar , Y. Lan , D. S. Leonard , S. Li , Z. Li , C. Licciardi , Y. H. Lin , R. MacLellan , T. Michel , B. Mong , D. Moore , K. Murray , R. J. Newby , Z. Ning , O. Njoya , F. Nolet , K. Odgers , M. Oriunno , J. L. Orrell , I. Ostrovskiy , C. T. Overman , G. S. Ortega , S. Parent , A. Piepke , J. -F. Pratte , V. Radeka , E. Raguzin , T. Rao , S. Rescia , F. Retiere , A. Robinson , T. Rossignol , P. C. Rowson , N. Roy , R. Saldanha , S. Sangiorgio , S. Schmidt , J. Schneider , D. Sinclair , K. Skarpaas , A. K. Soma , G. St-Hilaire , V. Stekhanov , T. Stiegler , X. L. Sun , M. Tarka , J. Todd , T. Tolba , R. Tsang , T. Tsang , F. Vachon , V. Veeraraghavan , G. Visser , J. -L. Vuilleumier , M. Wagenpfeil , M. Weber , W. Wei , U. Wichoski , G. Wrede , S. X. Wu , W. H. Wu , Z. Xuan , L. Yang , D. Yayun , Y. -R. Yen , O. Zeldovich , X. Zhang , J. Zhao , N. Zhe , Y. Zhou , T. Ziegler

We have measured the properties of scintillation light in liquid argon doped with xenon concentrations from 165 ppm to 10,010 ppm using a $^{22}$Na source. The energy transfer processes in the xenon-doped liquid argon are discussed in…

Instrumentation and Detectors · Physics 2021-02-03 Y. Y. Gan , M. Y. Guan , Y. P. Zhang , P. Zhang , C. G. Yang , Q. Zhao , Y. T. Wei , W. X. Xiong

We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX…

Cosmology and Nongalactic Astrophysics · Physics 2020-02-19 D. S. Akerib , S. Alsum , H. M. Araújo , X. Bai , A. J. Bailey , J. Balajthy , A. Baxter , P. Beltrame , E. P. Bernard , A. Bernstein , T. P. Biesiadzinski , E. M. Boulton , B. Boxer , P. Brás , S. Burdin , D. Byram , S. B. Cahn , M. C. Carmona-Benitez , C. Chan , A. A. Chiller , C. Chiller , A. Currie , J. E. Cutter , L. de Viveiros , A. Dobi , J. E. Y. Dobson , E. Druszkiewicz , B. N. Edwards , C. H. Faham , S. R. Fallon , A. Fan , S. Fiorucci , R. J. Gaitskell , V. M. Gehman , J. Genovesi , C. Ghag , K. R. Gibson , M. G. D. Gilchriese , E. Grace , C. Gwilliam , C. R. Hall , M. Hanhardt , S. J. Haselschwardt , S. A. Hertel , D. P. Hogan , M. Horn , D. Q. Huang , C. M. Ignarra , R. G. Jacobsen , O. Jahangir , W. Ji , K. Kamdin , K. Kazka , D. Khaitan , R. Knoche , E. V. Korolkova , S. Kravitz , V. A. Kudryavtsev , N. A. Larsen , E. Leason , C. Lee , B. G. Lenardo , K. T. Lesko , C. Levy , J. Liao , J. Lin , A. Lindote , M. I. Lopes , B. López-Paredes , A. Manalaysay , R. L. Mannino , N. Marangou , M. F. Marzioni , D. N. McKinsey , D. M. Mei , J. Mock , M. Moongweluwan , J. A. Morad , A. St. J. Murphy , A. Naylor , C. Nehrkorn , H. N. Nelson , F. Neves , A. Nilima , K. O'Sullivan , K. C. Oliver-Mallory , K. J. Palladino , E. K. Pease , L. Reichhart , Q. Riffard , G. R. C. Rischbieter , P. Rossiter , S. Shaw , T. A. Shutt , C. Silva , M. Solmaz , V. N. Solovov , P. Sorensen , S. Stephenson , T. J. Sumner , M. Szydagis , D. J. Taylor , R. Taylor , W. C. Taylor , B. P. Tennyson , P. A. Terman , D. R. Tiedt , W. H. To , M. Tripathi , L. Tvrznikova , U. Utku , S. Uvarov , A. Vacheret , V. Velan , J. R. Verbus , R. C. Webb , J. T. White , T. J. Whitis , M. S. Witherell , F. L. H. Wolfs , D. Woodward , J. Xu , K. Yazdani , S. K. Young , C. Zhang

We propose a new concept for a very low background multi-ton liquid xenon Dark Matter experiment. The detector consists of two concentric spheres and a charge readout device in the centre. Xenon between the two spheres forms a self-shield…

The krypton electroluminescence yield was studied, at room temperature, as a function of electric field in the gas scintillation gap. A large area avalanche photodiode has been used to allow the simultaneous detection of the…

Instrumentation and Detectors · Physics 2021-02-02 R. D. P. Mano , C. A. O. Henriques , F. D. Amaro , C. M. B. Monteiro

This paper presents a world-leading scintillation light yield among inorganic crystals measured from a 0.5~kg pure-CsI detector operated at 77 Kelvin. Scintillation photons were detected by two 2-inch Hamamatsu SiPM arrays equipped with…

Instrumentation and Detectors · Physics 2024-04-17 L. Wang , G. d. Li , Z. Y. Yu , X. H. Liang , T. A. Wang , F. Liu , X. L. Sun , C. Guo , X. Zhang , L. Yu , Y. D. Chen

A high-flow radon removal system based on cryogenic distillation was developed and constructed to reduce radon-induced backgrounds in liquid xenon detectors for rare event searches such as XENONnT. A continuous purification of the XENONnT…

Instrumentation and Detectors · Physics 2022-12-28 M. Murra , D. Schulte , C. Huhmann , C. Weinheimer

The NUCLEUS experiment aims to measure coherent elastic neutrino nucleus scattering of reactor anti-neutrinos using cryogenic calorimeters. Operating at an overburden of 3 m.w.e., muon-induced backgrounds are expected to be one of the…

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…

The design and performance of a 1.2 liter liquid xenon chamber equipped with 7 two-inch photomultiplier tubes, with the purpose of studying the scintillation response of xenon to gamma-rays and neutrons, is described. Measurements with…

This paper will discuss the microphysical simulation of interactions in liquid xenon, the active detector medium in many leading rare-event searches for new physics, and describe experimental observables useful for understanding detector…

A 30-g xenon bubble chamber, operated at Northwestern University in June and November 2016, has for the first time observed simultaneous bubble nucleation and scintillation by nuclear recoils in a superheated liquid. This chamber is…

Instrumentation and Detectors · Physics 2017-06-12 D. Baxter , C. J. Chen , M. Crisler , T. Cwiok , C. E. Dahl , A. Grimsted , J. Gupta , M. Jin , R. Puig , D. Temples , J. Zhang

A simple hole-type secondary scintillation structure (2 mm-hole, 5 mm-pitch, 5 mm-thickness) is introduced and its operation demonstrated in pure xenon in the pressure range 2-10 bar. The new device, characteristically translucent, has been…

Instrumentation and Detectors · Physics 2020-08-26 D. González-Díaz , M. Fontaíña , D. García Castro , B. Mehl , R. de Oliveira , S. Williams , F. Monrabal , M. Querol , V. Álvarez

The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium…