English
Related papers

Related papers: Cold-electron bolometers for future mm and sub-mm …

200 papers

We perform experimental and theoretical study of the parallel-series arrays of Cold-Electron Bolometers (CEBs) integrated into a cross-slot antenna and composed with an immersion silicon lens. The purpose is to determine the absorption…

Instrumentation and Detectors · Physics 2015-10-23 A. S. Mukhin , A. V. Gordeeva , L. S. Revin , A. E. Abashin , A. A. Shishov , A. L. Pankratov , S. Mahashabde , L. S. Kuzmin

An important phenomenon limiting the sensitivity of bolometric detectors for future space missions is the interaction with cosmic rays. We tested the sensitivity of Cold Electron Bolometers (CEBs) to ionizing radiation using gamma-rays from…

Instrumentation and Methods for Astrophysics · Physics 2014-04-01 Maria Salatino , Paolo de Bernardis , Leonid Kuzmin , Sumedh Mahashabde , Silvia Masi

We describe here a focal plane array of Cold-Electron Bolometer (CEB) detectors integrated in a Frequency Selective Surface (FSS) for the 350 GHz detection band of the OLIMPO balloon-borne telescope. In our architecture, the two terminal…

Instrumentation and Methods for Astrophysics · Physics 2015-05-12 Sumedh Mahashabde , Alexander Sobolev , Andreas Bengtsson , Daniel Andrén , Michael Tarasov , Maria Salatino , Paolo de Bernardis , Silvia Masi , Leonid Kuzmin

We investigate theoretically the possibility of using the cold-electron bolometer (CEB) as a counter for 1 cm wavelength (30 GHz) photons. To reduce the flux of photons from the environment, which interact with the detector, the bath…

Mesoscale and Nanoscale Physics · Physics 2019-12-30 D. V. Anghel , L. S. Kuzmin

In the field of astrophysics, the faint signal from distant galaxies and other dim cosmological sources at millimeter and submillimeter wavelengths require the use of high-sensitivity experiments. Cryogenics and the use of low-temperature…

Instrumentation and Methods for Astrophysics · Physics 2020-09-22 Lionel Duband , Thomas Prouve , James Bock , Lorenzo Moncelsi , Alessandro Schillaci

Precise measurements of the cosmic microwave background (CMB) are crucial in cosmology, because any proposed model of the universe must account for the features of this radiation. Of all CMB measurements that the scientific community has…

Instrumentation and Methods for Astrophysics · Physics 2013-07-08 Claudia Nones , Stefanos Marnieros , Alain Benoit , Laurent Bergé , Aurelien Bideau , Philippe Camus , Louis Dumoulin , Alessandro Monfardini , Olivier Rigaut

We describe optical characterisation of a Strained Silicon Cold Electron Bolometer (CEB), operating on a $350~\mathrm{mK}$ stage, designed for absorption of millimetre-wave radiation. The silicon Cold Electron Bolometer utilises Schottky…

A new type of bolometer arrays sensitive in the Far Infrared and Submillimeter range has been developped and manufactured by CEA/LETI/SLIR and will be integrated in the PACS instrument onboard the Herschel Space Observatory (launch date…

This article reviews the state of rapidly emerging terahertz hot-electron nanobolometers (nano-HEB), which are currently among of the most sensitive radiation power detectors at submillimeter wavelengths. With the achieved noise equivalent…

Instrumentation and Detectors · Physics 2014-01-22 Boris S. Karasik , Andrei V. Sergeev , Daniel E. Prober

Cold electron bolometers have shown their suitability for use in modern fundamental physical experiments. Fabrication and measurements of the samples with cold-electron bolometers integrated into coplanar antennas are performed in this…

For the first time, we have measured the optical noise equivalent power (NEP) in titanium (Ti) superconducting hot-electron nanobolometers (nano-HEBs). The bolometers were 2{\mu}mx1{\mu}mx20nm and 1{\mu}mx1{\mu}mx20nm planar antenna-coupled…

Instrumentation and Methods for Astrophysics · Physics 2012-07-09 Boris S. Karasik , Robin Cantor

A precision measurement of the cosmic-ray positron spectrum may help to solve the puzzle of the nature of dark matter. Pairwise annihilation of neutralinos, predicted by some supersymmetric extensions to the standard model of particle…

Instrumentation and Methods for Astrophysics · Physics 2010-02-17 H. Gast , R. Greim , T. Kirn , G. Roper Yearwood , S. Schael

The CEA/LETI and CEA/SAp started the development of far-infrared filled bolometer arrays for space applications over a decade ago. The unique design of these detectors makes possible the assembling of large focal planes comprising thousands…

Instrumentation and Methods for Astrophysics · Physics 2015-05-19 Nicolas Billot , M. Sauvage , L. Rodriguez , B. Horeau , C. Kiss , H. Aussel , K. Okumura , O. Boulade , B. Altieri , A. Poglitsch , P. Agnese

Measurements of the cosmic microwave background (CMB) allow high precision observation of the cosmic plasma at redshift z~1100. After the success of the NASA satellite COBE, that in 1992 provided the first detection of the CMB anisotropy,…

The best measurement of the cosmic ray positron flux available today was performed by the HEAT balloon experiment more than 10 years ago. Given the limitations in weight and power consumption for balloon experiments, a novel approach was…

Astrophysics · Physics 2008-11-26 P. von Doetinchem , H. Gast , T. Kirn , G. Roper Yearwood , S. Schael

The latest generation of cosmic microwave background (CMB) telescopes is searching for the undetected faint signature of gravitational waves from inflation in the polarized signal of the CMB. To achieve the unprecedented levels of…

Instrumentation and Methods for Astrophysics · Physics 2013-01-08 Darcy Barron , Matt Atlas , Brian Keating , Ron Quillin , Nathan Stebor , Brandon Wilson

We have observed cosmic-ray electrons from 10 GeV to 800 GeV by a long duration balloon flight using Polar Patrol Balloon (PPB) in Antarctica. The observation was carried out for 13 days at an average altitude of 35 km in January 2004. The…

The balloon-borne LSPE mission is optimized to measure the linear polarization of the Cosmic Microwave Background at large angular scales. The Short Wavelength Instrument for the Polarization Explorer (SWIPE) is composed of 3 arrays of…

Transition Edge Sensor (TES) bolometers are a well-established technology with a strong track record in experimental cosmology, making them ideal for current and future radio astronomy instruments. The Tomographic Ionized-carbon Mapping…

Instrumentation and Methods for Astrophysics · Physics 2025-10-06 Victoria L. Butler , James J. Bock , Dongwoo T. Chung , Abigail T. Crites , King Lau , Ian Lowe , Dan P. Marrone , Evan C. Mayer , Benjamin J. Vaughan , Michael Zemcov

We report on efforts to improve the speed of low-G far-infrared transition-edged-sensed bolometers. We use a fabrication process that does not require any dry etch steps to reduce heat capacity on the suspended device and measure a…

‹ Prev 1 2 3 10 Next ›