Related papers: Characterization of neutron transmutation doped (N…
A program to develop low temperature (mK) sensors with neutron transmutation doped Ge for rare event studies with a cryogenic bolometer has been initiated. For this purpose, semiconductor grade Ge wafers are irradiated with thermal neutron…
In neutron transmutation doped germanium, the thermal neutron fluence of reactor irradiation is as high as 10$^{18}$~n$\cdot$cm$^{-2}$. For radiological safety reasons, general Co or Au neutron flux monitors cannot be easily used. We have…
The Low Energy Neutron Source (LENS) is an accelerator-based pulsed cold neutron facility under construction at the Indiana University Cyclotron Facility (IUCF). The idea behind LENS is to produce pulsed cold neutron beams starting with…
The demand for new thermal neutron detectors as an alternative to 3He tubes in research, industrial, safety and homeland security applications, is growing. These needs have triggered research and development activities about new generations…
Energy-resolved neutron imaging at a pulsed source utilizes the energy-dependent neutron transmission measured via time-of-flight to extract quantitative information about the internal microstructure of an object. At the RADEN instrument at…
The thermal neutrons were registered using a two-detector module based on two planar Si detectors: with a neutron converter from natural metallic Gd and without a converter. To obtain thermal neutrons we used a 239Pu-Be({\alpha},n) fast…
A series of test experiments on three different Si-based neutron detectors, namely a 1-d 128 channel, 0.5 mm space resolution Si microstrip sensor coupled to natural Gd converter, a medium size ? 1 cm2 PIN diode coupled to nGd2O3 or…
We report the low temperature carrier transport properties of a series of nominally uncompensated neutron-transmutation doped (NTD) ^{70} Ge:Ga samples very close to the critical concentration N_c for the metal-insulator transition. The…
During 2014 the second experimental area EAR2 was completed at the n-TOF neutron beam facility at CERN. As the neutrons are produced via spallation, by means of a high-intensity 20 GeV pulsed proton beam impinging on a thick target, the…
A neutron detector based on EJ301 liquid scintillator has been employed at EAST to measure the neutron energy spectrum for D-D fusion plasma. The detector was carefully characterized in different quasi-monoenergetic neutron fields generated…
The AMANDE facility produces monoenergetic neutron fields from 2 keV to 20 MeV for metrological purposes. To be considered as a reference facility, fluence and energy distributions of neutron fields have to be determined by primary…
The time-of-flight Highly Granular Neutron Detector (HGND) with a multilayer longitudinal structure of interleaved absorber and scintillator plates, high transverse granularity and a time resolution of about 150 ps is currently under…
Thermoluminescence detectors (TLD) were used for dose measurements at JET. Several hundreds of LiF detectors of various types, standard LiF:Mg,Ti and highly sensitive LiF:Mg,Cu,P were produced. LiF detectors consisting of natural lithium…
Accelerator-driven system (ADS) facilities world-wide opens new opportunities for nuclear physics investigations, so that a high flux of neutrons through spallation reactions can be produced at these facilities. It is known that the…
Deep-level transient spectroscopy and temperature-dependent time-resolved photoluminescence experiments are performed on identical InAs nBn photodetector structures as a function of in-situ and ex-situ 63 MeV proton irradiation to assess…
The neutron capture cross section of $^{154}$Gd was measured from 1 eV to 300 keV in the experimental area located 185 m from the CERN n\_TOF neutron spallation source, using a metallic sample of gadolinium, enriched to 67$\%$ in…
We have developed a nuclear magnetic resonance spectrometer with a series tuned input circuit for measurements on samples at millikelvin temperatures based on an integrated two-stage superconducting quantum interference device current…
Neutron Resonance Transmission Analysis (NRTA) is a spectroscopic technique which uses the resonant absorption of neutrons in the epithermal range to infer the isotopic composition of an object. This spectroscopic technique has relevance in…
Samples were examined using a superconducting (Nb) neutron imaging system employing a delay-line technique which in previous studies was shown to have high spatial resolution. We found excellent correspondence between neutron transmission…
A first study of neutron tagging is conducted in Super--Kamiokande, a 50,000-ton water Cherenkov detector. The tagging efficiencies of thermal neutrons are evaluated in a 0.2 % GdCl$_{3}$-water solution and pure water. They are determined…