Related papers: Metal artifact reduction based on the combined pri…
Spectral computed tomography has received considerable interest in recent years since spectral measurements contain much richer information about the object of interest. In spectral computed tomography, we are interested in the energy…
Automatic generation of morphed face images often produces ghosting artifacts due to poorly aligned structures in the input images. Manual processing can mitigate these artifacts. However, this is not feasible for the generation of large…
Computed tomography (CT) has been developed as a non-destructive technique for observing minute internal images of samples. It has been difficult to obtain photo-realistic (clean or clear) CT images due to various unwanted artifacts…
Purpose: Patient movement affects image quality in oral and maxillofacial cone-beam CT imaging. While many efforts are made to minimize the possibility of motion during a scan, relatively little attention has been given to motion…
This work is concerned with applying iterative image reconstruction, based on constrained total-variation minimization, to low-intensity X-ray CT systems that have a high sampling rate. Such systems pose a challenge for iterative image…
In digital images, the performance of optical aberration is a multivariate degradation, where the spectral of the scene, the lens imperfections, and the field of view together contribute to the results. Besides eliminating it at the…
Segmenting anatomical structures in medical images has been successfully addressed with deep learning methods for a range of applications. However, this success is heavily dependent on the quality of the image that is being segmented. A…
Undersampled CT volumes minimize acquisition time and radiation exposure but introduce artifacts degrading image quality and diagnostic utility. Reducing these artifacts is critical for high-quality imaging. We propose a computationally…
In dental cone-beam computed tomography (CBCT), compact and cost-effective system designs often use small detectors, resulting in a truncated field of view (FOV) that does not fully encompass the patient's head. In iterative reconstruction…
Error-bounded lossy compression has been regarded as a promising way to address the ever-increasing amount of scientific data in today's high-performance computing systems. Pre-quantization, a critical technique to remove sequential…
The JPEG image compression algorithm is the most popular method of image compression because of its ability for large compression ratios. However, to achieve such high compression, information is lost. For aggressive quantization settings,…
Non-destructive characterization of multi-layered structures that can be accessed from only a single side is important for applications such as well-bore integrity inspection. Existing methods related to Synthetic Aperture Focusing…
Numerous factors could lead to partial deteriorations of medical images. For example, metallic implants will lead to localized perturbations in MRI scans. This will affect further post-processing tasks such as attenuation correction in…
Limited angle problem is a challenging issue in x-ray computed tomography (CT) field. Iterative reconstruction methods that utilize the additional prior can suppress artifacts and improve image quality, but unfortunately require increased…
Metal artifacts present a frequent challenge to cone-beam CT (CBCT) in image-guided surgery, obscuring visualization of metal instruments and adjacent anatomy. Recent advances in mobile C-arm systems have enabled 3D imaging capacity with…
The need for tomographic reconstruction from sparse measurements arises when the measurement process is potentially harmful, needs to be rapid, or is uneconomical. In such cases, prior information from previous longitudinal scans of the…
X-ray computed tomography (CT) is one of widely used diagnostic tools for medical and dental tomographic imaging of the human body. However, the standard filtered backprojection reconstruction method requires the complete knowledge of the…
We introduce a new CT image reconstruction algorithm that is less affected by various artifacts. The new reconstruction algorithm is a method of minimizing the difference between synchrotron X-ray tomography data and sinograms generated…
This paper provides a fast and patient-specific scatter artifact correction method for cone-beam computed tomography (CBCT) used in image-guided interventional procedures. Due to increased irradiated volume of interest in CBCT imaging,…
Total variation(TV) regularization is applied to X-Ray computed tomography(CT) in an effort to reduce metal artifacts. Tikhonov regularization with $L^2$ data fidelity term and total variation regularization is augmented in this novel model…