English
Related papers

Related papers: A simple technique for gamma ray and cosmic ray sp…

200 papers

With the advent of high repetition rate laser facilities, novel diagnostic tools compatible with these advanced specifications are required. This paper presents the design of an active gamma-ray spectrometer intended for these high…

A simple device for determining the azimuthal location of a source of gamma radiation, using ideas from astrophysical gamma-ray burst detection, is described. A compact and robust detector built from eight identical modules, each comprising…

Instrumentation and Detectors · Physics 2015-12-09 D. Hanna , L. Sagnières , P. Boyle , A. M. L. MacLeod

In this paper we present a method of scintillation detector energy calibration using the gamma-rays. The technique is based on the Compton scattering of gamma-rays in a scintillation detector and subsequent photoelectric absorption of the…

Instrumentation and Detectors · Physics 2016-04-20 S. V. Bakhlanov , N. V. Bazlov , A. V. Derbin , I. S. Drachnev , A. S. Kayunov , V. N. Muratova , D. A. Semenov , E. V. Unzhakov

A new type of neutron detector, named Stack Structure Solid organic Scintillator (S$^4$), consisting of multi-layer plastic scintillators with capability to suppress low-energy $\gamma$ rays under high-counting rate has been constructed and…

Plastic scintillators are widely used as particle detectors in many fields, mainly, medicine, particle physics and astrophysics. Traditionally, they are coupled to a photo-multplier (PMT) but now silicon photo-multipliers (SiPM) are…

Instrumentation and Methods for Astrophysics · Physics 2018-09-28 G. Ros , G. Sáez-Cano , G. A. Medina-Tanco , A. D. Supanitsky

We report on the construction and upgrade of a Lawrence Berkeley National Laboratory Cosmic Muons Detector. We modify the electronics and mechanics to achieve a highly efficient gamma-ray and cosmic-ray detector. Each detector module uses a…

Instrumentation and Detectors · Physics 2011-07-25 Abdel G. Bachri , Perry C. Grant , Azriel Goldschmidt

Detectors based on liquid or gas xenon have been used and are in use for a number of applications, in particular for the detection of gamma rays. Xenon is a well-suited medium for gamma spectroscopy thanks to its high atomic number and,…

Instrumentation and Detectors · Physics 2013-09-10 F. Resnati

In gamma ray imaging, a scintillation crystal is typically used to convert the gamma radiation into visible light. Photosensors are used to transform this light into measurable signals. Several types of photosensors are currently in use…

A new type of compact high resolution high sensitivity gamma ray spectrometer for short pulse intense 250 keV to 50 MeV gamma rays has been developed by combining the principles of scintillators and attenuation spectrometers. The first…

We demonstrated the feasibility of measuring the axial coordinate of a gamma quantum interaction point in a plastic scintillator bar via the detection of scintillation photons escaping from the scintillator with an array of…

Detection of photons with scintillating inorganic crystals in the high-energy range (> 0.1 MeV) will be discussed, making a comparison with other available methods. Energy resolutions up to 2 % at 662 keV and fast decay time of the order of…

Instrumentation and Detectors · Physics 2025-05-13 M. Bonesini

Among the top priorities for high-energy astronomy in the coming decade are sensitive surveys in the hard X-ray/soft \gamma-ray (10-600 keV) and medium-energy \gamma-ray (0.2-80 MeV) bands. Historically, observations in the soft and medium…

Instrumentation and Methods for Astrophysics · Physics 2013-02-26 Alexei Ulyanov , Lorraine Hanlon , Sheila McBreen , Suzanne Foley , David Byrne

We have developed a compact Compton gamma-ray imager with a large field of view and a low channel-count that is capable of quickly localizing gamma-ray sources in the few hundred keV - several MeV range. The two detector planes (scatter and…

Instrumentation and Detectors · Physics 2015-06-18 A. M. L. MacLeod , P. J. Boyle , D. S. Hanna , P. R. B. Saull , L. E. Sinclair , H. C. J. Seywerd

Gamma sources are routinely used to calibrate the energy scale and resolution of liquid scintillator detectors. However, non-scintillating material surrounding the source introduces energy losses, which may bias the determination of the…

Instrumentation and Detectors · Physics 2021-09-01 Feiyang Zhang , Rui Li , Jiaqi Hui , Jianglai Liu , Yue Meng , Yuanyuan Zhang

A method of determination of a gamma quantum absorption point in a plastic scintillator block using a matrix of wavelength-shifting (WLS) strips is proposed. Application of this method for improvement of position resolution in newly…

We are designing an all-scintillator Compton gamma imager for use in security investigations and remediation actions involving radioactive threat material. To satisfy requirements for a rugged and portable instrument, we have chosen solid…

Instrumentation and Detectors · Physics 2009-06-28 L. E. Sinclair , D. S. Hanna , A. M. L. MacLeod , P. R. B. Saull

Spectroscopic measurements are presented using the PID350 pixelated gamma radiation detectors. A high-speed data acquisition system has been developed in order to reduce the data loss during the data reading in case of a high flux of…

Instrumentation and Detectors · Physics 2010-11-16 K. Karafasoulis , K. Zachariadou , S. Seferlis , I. Papadakis , D. Loukas , C. Lambropoulos , C. Potiriadis

The combination of plastic scintillators with Silicon Photo-Multipliers (SiPMs) is widely used for detecting radiation in high-energy astrophysics, particle physics, neutrino physics, or medical physics. An example of application for this…

Instrumentation and Methods for Astrophysics · Physics 2025-02-14 Nicolas De Angelis , Franck Cadoux , Coralie Husi , Merlin Kole , Sławomir Mianowski

An astrophysics application of a low noise Double-sided Silicon Strip Detector (DSSD) is described. A Semiconductor Multiple-Compton Telescope (SMCT) is being developed to explore the gamma-ray universe in the 0.1-20 MeV energy band.…

High Energy Physics - Experiment · Physics 2009-11-10 Hiroyasu Tajima

This article describes simulations of scattering of annihilation gamma quanta in a strip of plastic scintillator. Such strips constitute basic detection modules in a newly proposed Positron Emission Tomography which utilizes plastic…

‹ Prev 1 2 3 10 Next ›