Related papers: Active Faraday optical frequency standards
We propose a method to continuously frequency shift a target laser that is frequency stabilized by a reference laser, which is several hundreds of nanometers detuned. We demonstrate the technique using the 5S 1/2 to 5P 3/2 to 29D 5/2…
We report on an absolute frequency measurement of the ${\rm Lu}^{+}\,(^{3}\rm D_1)$ standard frequency which is defined as the hyperfine-average of $^{1}\rm S_0$ to $^{3}\rm D_1$ optical clock transitions in $^{176}{\rm Lu}^{+}$. The…
We present a measurement of the absolute frequency of the 5s$^2$ $^1$S$_0$ to 5s5p $^3$P$_0$ transition in $^{87}$Sr, which is a secondary representation of the SI second. We describe the optical lattice clock apparatus used for the…
We demonstrate atomic filtering of frequency-degenerate photon pairs from a sub-threshold optical parametric oscillator (OPO). The filter, a modified Faraday anomalous dispersion optical filter (FADOF), achieves 70% peak transmission…
Recent advances in the development of ultra-low loss silicon nitride integrated photonic circuits have heralded a new generation of integrated lasers capable of reaching fiber laser coherence. However, these devices presently are based on…
Compact optical clocks with high stability are essential for next-generation frequency standard field applications, from navigation to geodesy, yet existing vapor cell clock systems have remained confined to fractional instabilities over…
We measured the absolute frequency of the optical clock transition 1S0 (F = 1/2) - 3P0 (F = 1/2) of 171Yb atoms confined in a one-dimensional optical lattice and it was determined to be 518 295 836 590 863.5(8.1) Hz. The frequency was…
We propose a new frequency standard based on a $4f^{14} 6s6p~ ^3\!P_0 - 4f^{13} 6s^2 5d ~(J=2)$ transition in neutral Yb. This transition has a potential for high stability and accuracy and the advantage of the highest sensitivity among…
We demonstrate a means of detecting weak optical transitions in cold atoms that undergo cyclic routines with high sensitivity. The gain in sensitivity is made by probing atoms on alternate cycles leading to a regular modulation of the…
We report a frequency measurement of the 1S0-3P0 transition of 87Sr atoms in an optical lattice clock. The frequency is determined to be 429 228 004 229 879 (5) Hz with a fractional uncertainty that is comparable to state-of-the-art optical…
We describe a new scheme for the measurement of mean photon flux at an arbitrary optical sideband frequency using homodyne detection. Experimental implementation of the technique requires an AOM in addition to the homodyne detector, and…
Highly frequency-stable lasers are a ubiquitous tool for optical frequency metrology, precision interferometry, and quantum information science. While making a universally applicable laser is unrealistic, spectral noise can be tailored for…
We demonstrate an optical data wavelength converter based on an electrically driven photonic molecule structure comprising two coupled active silicon microring resonators. The converter, supplied by a continuous-wave (CW) microwave drive…
We report absolute frequency measurements of 81 hyperfine components of the rovibrational transitions of molecular iodine at 578 nm using the second harmonic generation of an 1156-nm external-cavity diode laser and a fiber-based optical…
We present the new absolute frequency measurement of ytterbium (171Yb) obtained at INRiM with the optical lattice clock IT-Yb1 against the cryogenic caesium (133Cs) fountain IT-CsF2, evaluated through a measurement campaign that lasted 14…
We present a standalone frequency-offset locking system for controlling narrow-linewidth lasers using off-the-shelf electronic components. We lock two frequency-doubled 1560 nm lasers to a stable primary laser operating at 780 nm via their…
We consider the frequency shift in optical lattice clocks which arises from the coupling of the electronic motion to the atomic motion within the lattice. For the simplest of 3-D lattice geometries this coupling is shown to only affect…
We propose a new scheme of microwave frequency standards based on pulsed coherent optical information storage. Unlike the usual frequency reference where the Ramsey fringe is printed on the population of a certain state, we print the Ramsey…
We achieve a compact optical frequency standard with an extended cavity diode laser locked to the 459 nm 6S$_{1/2}$ - 7P$_{1/2}$ transition of thermal $^{133}$Cs atoms in a $\phi$ 10 mm $\times$ 50 mm glass cell, using modulation transfer…
We demonstrate a one-dimensional optical lattice clock with ultracold 171Yb atoms, which is free from the linear Zeeman effect. The absolute frequency of the 1S0(F = 1/2) - 3P0(F = 1/2) clock transition in 171Yb is determined to be 518 295…