Related papers: How Strong Are Streak Artifacts in Limited Angle C…
This paper considers the reconstruction problem in Acousto-Electrical Tomography, i.e., the problem of estimating a spatially varying conductivity in a bounded domain from measurements of the internal power densities resulting from…
Computed Tomography (CT) reconstruction is a fundamental component to a wide variety of applications ranging from security, to healthcare. The classical techniques require measuring projections, called sinograms, from a full 180$^\circ$…
Hard X-ray and low-energy gamma-ray coded-aperture imaging instruments have been highly successful as high-energy surveyors and transient-source discoverers and trackers over the past decades. Albeit having relatively low sensitivity as…
Recently, compressed sensing (CS) computed tomography (CT) using sparse projection views has been extensively investigated to reduce the potential risk of radiation to patient. However, due to the insufficient number of projection views, an…
Project ILATO focuses on Improving Limited Angle computed Tomography by Optical data integration in order to enhance image quality and shorten acquisition times in X-ray based industrial quality inspection. Limited angle computed tomography…
We present an effective post-processing method to reduce the artifacts from sparsely reconstructed cone-beam CT (CBCT) images. The proposed method is based on the state-of-the-art, image-to-image generative models with a perceptual loss as…
Low x-ray dose is desirable in x-ray computed tomographic (CT) imaging due to health concerns. But low dose comes with a cost of low signal artifacts such as streaks and low frequency bias in the reconstruction. As a result, low signal…
This paper presents an iterative inversion algorithm for computed tomography image reconstruction that performs well in terms of accuracy and speed using limited data. The computational method combines an image domain technique and…
This work is concerned with applying iterative image reconstruction, based on constrained total-variation minimization, to low-intensity X-ray CT systems that have a high sampling rate. Such systems pose a challenge for iterative image…
The problem of image segmentation is known to become particularly challenging in the case of partial occlusion of the object(s) of interest, background clutter, and the presence of strong noise. To overcome this problem, the present paper…
Due to the energy-dependent nature of the attenuation coefficient and the polychromaticity of the X-ray source, beam hardening effect occurs when X-ray photons penetrate through an object, causing a nonlinear projection data. When a linear…
Robustness of deep learning methods for limited angle tomography is challenged by two major factors: a) due to insufficient training data the network may not generalize well to unseen data; b) deep learning methods are sensitive to noise.…
Metal objects pose a significant challenge in cone-beam computed tomography, as their strong and energy-dependent X-ray attenuation leads to inconsistent projections and severe streaking and shading artifacts in reconstructed images. These…
Metal artifact reduction (MAR) in computed tomography (CT) is a notoriously challenging task because the artifacts are structured and non-local in the image domain. However, they are inherently local in the sinogram domain. Thus, one…
The possibility of obtaining robust edge state of light by mimicking the topological properties of solid state system, have brought a profound impact on optical sciences. With the advent of high-brilliance, accelerator-driven light sources…
In transmission X-ray microscopy (TXM) systems, the rotation of a scanned sample might be restricted to a limited angular range to avoid collision to other system parts or high attenuation at certain tilting angles. Image reconstruction…
During X-ray computed tomography (CT) scanning, metallic implants carrying with patients often lead to adverse artifacts in the captured CT images and then impair the clinical treatment. Against this metal artifact reduction (MAR) task, the…
The inversion of linear systems is a fundamental step in many inverse problems. Computational challenges exist when trying to invert large linear systems, where limited computing resources mean that only part of the system can be kept in…
A long-standing challenge in tomography is the 'missing wedge' problem, which arises when the acquisition of projection images within a certain angular range is restricted due to geometrical constraints. This incomplete dataset results in…
Computed Tomography (CT) is an imaging technique where information about an object are collected at different angles (called projections or scans). Then the cross-sectional image showing the internal structure of the slice is produced by…