English
Related papers

Related papers: Modulated Luminescent Tomography

200 papers

A disordered structure embedding an active gain material and able to lase is called random laser (RL). The RL spectrum may appear either like a set of sharp resonances or like a smooth line superimposed to the fluorescence. A recent letter…

Optics · Physics 2015-06-03 M. Leonetti , C. Conti , C. Lopez

Wavefront shaping correction makes it possible to image fluorescent particles deep inside scattering tissue. This requires determining a correction mask to be placed in both excitation and emission paths. Standard approaches select…

Optics · Physics 2022-06-22 Dror Aizik , Ioannis Gkioulekas , Anat Levin

We derive a simple model for a two transverse mode laser (that considers the TEM00 and TEM10 modes) in which an injected signal with the shape of the TEM10 mode but a frequency close to that of the TEM00 mode is injected.

Optics · Physics 2008-11-11 G. J. de Valcarcel , E. Roldan , K. Staliunas

We experimentally demonstrate amplitude and phase modulation of a time-energy entangled two-photon wave function. The entangled photons are produced by spontaneous parametric down-conversion, spectrally dispersed in an prism compressor,…

Quantum Physics · Physics 2009-01-23 F. Zäh , M. Halder , T. Feurer

We study photoinduced optical responses of one-dimensional strongly correlated electron systems. The optical conductivity spectra are calculated for the ground state and a photoexcited state in the one-dimensional Hubbard model at half…

Strongly Correlated Electrons · Physics 2009-11-11 Nobuya Maeshima , Kenji Yonemitsu

Improving resolution and sensitivity will widen possible medical applications of magnetic particle imaging. Pulsed excitation promises such benefits, at the cost of more complex hardware solutions and restrictions on drive field amplitude…

Quantifying material mass and electron density from computed tomography (CT) reconstructions can be highly valuable in certain medical practices, such as radiation therapy planning. However, uniquely parameterising the X-ray attenuation in…

Medical Physics · Physics 2019-04-30 Jonathan H. Mason , Alessandro Perelli , William H. Nailon , Mike E. Davies

Focusing of atoms with light potentials is studied. In particular, we consider strongly confined, cylindrical symmetric potential, and demonstrate their applications in both red and blue-detuned focusing of atoms. We also study the…

Quantum Physics · Physics 2009-11-07 Lars Egil Helseth

Flat-panel cone-beam CT (CBCT) has been applied clinically in a number of high-resolution applications. Increasing geometric magnification can potentially improve resolution, but also increases blur due to an extended x-ray focal-spot. We…

Medical Physics · Physics 2016-10-18 Steven Tilley , Wojciech Zbijewski , Jeffrey H. Siewerdsen , J. Webster Stayman

Ultrasound-modulated optical tomography enables sharp 3D optical imaging of tissues and other turbid media, but the light modulation signals are hard to sensitively measure. A common solution, involving photorefractive crystals, enables the…

Optics · Physics 2018-04-19 Steven J. Byrnes

We experimentally measure the monochromatic transmission matrix (TM) of an optical multiple scattering medium using a spatial light modulator together with a phase-shifting interferometry measurement method. The TM contains all information…

Optics · Physics 2015-05-28 S. M. Popoff , G. Lerosey , M. Fink , A. C. Boccara , S. Gigan

X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we…

Instrumentation and Detectors · Physics 2015-01-29 Burkhant Suerfu , Christopher G. Tully

The capacity to manipulate magnetization in two-dimensional dilute magnetic semiconductors (2D-DMSs) using light, specifically in magnetically doped transition metal dichalcogenide (TMD) monolayers (M-doped TX2, where M = V, Fe, Cr; T = W,…

We observe experimentally the transfer of angular spectrum and image formation in the process of stimulated parametric down-conversion. Images and interference patterns can be transferred either from the pump or the auxiliary laser beams to…

We demonstrate theoretical and experimentally how it is possible to manipulate an entangled angular spectrum of twin beams, in order to reconstruct correlated images with coincidence detection. The entangled angular spectrum comes from the…

Quantum Physics · Physics 2009-11-10 D. P. Caetano , P. H. Souto Ribeiro

Ghost imaging, Fourier transform spectroscopy, and the newly developed Hadamard transform crystallography are all examples of multiplexing measurement strategies. Multiplexed experiments are performed by measuring multiple points in space,…

Applied Physics · Physics 2020-04-22 Thomas J. Lane , Daniel Ratner

We demonstrate a means of creating a digital image by using a two axis tilt micromirror to scan a scene. For each different orientation we extract a single grayscale value from the mirror and combine them to form a single composite image.…

Optics · Physics 2009-11-13 R. Andrew Hicks , Vasileios T. Nasis , Timothy P. Kurzweg

We consider the linearized electrical impedance tomography problem in two dimensions on the unit disk. By a linearization around constant coefficients and using a trigonometric basis, we calculate the linearized Dirichlet-to-Neumann…

Numerical Analysis · Mathematics 2017-06-08 Stefan Kindermann

X-ray tomography has been studied in various fields. Although a great deal of effort has been directed at reconstructing the projection image set from a rigid-type specimen, little attention has been addressed to the reconstruction of…

Computational Physics · Physics 2018-07-04 Kyungtaek Jun , Dongwook Kim

X-ray microtomography at synchrotron sources is fundamentally limited by the high radiation dose applied to the samples, which restricts investigations to non-native tissue states and thereby compromises the biological relevance of the…

‹ Prev 1 8 9 10 Next ›